메뉴 건너뛰기




Volumn 160, Issue 1, 1998, Pages 67-71

Buckling of cylinders may cause prolonged penile pain after prosthesis implantation: A case control study using magnetic resonance imaging of the penis

Author keywords

Complications; Pain; Penile erection; Penis; Prosthesis

Indexed keywords

ARTICLE; CONTROLLED STUDY; ERECTILE DYSFUNCTION; HUMAN; IMAGE ANALYSIS; MAJOR CLINICAL STUDY; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; PENIS PROSTHESIS; POSTOPERATIVE PAIN; PRIORITY JOURNAL; RISK FACTOR;

EID: 0344678335     PISSN: 00225347     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0022-5347(01)63033-7     Document Type: Article
Times cited : (34)

References (20)
  • 1
    • 0344814443 scopus 로고
    • Prevention and correction of penile implant problems
    • lesson 13
    • Mulcahy, J. J.: Prevention and correction of penile implant problems. AUA Update Series, lesson 13, vol. 27, 1994.
    • (1994) AUA Update Series , vol.27
    • Mulcahy, J.J.1
  • 2
    • 0027363332 scopus 로고
    • Reoperation for penile prosthesis implantation
    • Lewis, R. W. and McLaren, R.: Reoperation for penile prosthesis implantation. Probl. Urol., 7: 381, 1993.
    • (1993) Probl. Urol. , vol.7 , pp. 381
    • Lewis, R.W.1    McLaren, R.2
  • 3
    • 0024561089 scopus 로고
    • Penile prosthesis surgery: Review of ten-year experience and examination of reoperations
    • Kabalin, J. N. and Kessler, R.: Penile prosthesis surgery: review of ten-year experience and examination of reoperations. Urology, 33: 17, 1989.
    • (1989) Urology , vol.33 , pp. 17
    • Kabalin, J.N.1    Kessler, R.2
  • 6
    • 0029655885 scopus 로고    scopus 로고
    • Ultrex cylinders: Problems with the uncontrolled lengthening (the S-shaped deformity)
    • Wilson, S. K., Cleves, M. A. and Delk, J. R., Jr.: Ultrex cylinders: problems with the uncontrolled lengthening (the S-shaped deformity). J. Urol., 155: 135, 1996.
    • (1996) J. Urol. , vol.155 , pp. 135
    • Wilson, S.K.1    Cleves, M.A.2    Delk J.R., Jr.3
  • 7
    • 0027957806 scopus 로고
    • Mentor Alpha 1 inflatable penile prosthesis: Patient satisfaction and device reliability
    • Garber, B. B.: Mentor Alpha 1 inflatable penile prosthesis: patient satisfaction and device reliability. Urology, 43: 214, 1994.
    • (1994) Urology , vol.43 , pp. 214
    • Garber, B.B.1
  • 8
    • 0027166297 scopus 로고
    • Clinical experience with Mentor Alpha 1 inflatable penile prosthesis. Report on 333 cases
    • Randrup, E., Wilson, S., Mobley, D., Suarez, G., Mekras, G. and Baum, N.: Clinical experience with Mentor Alpha 1 inflatable penile prosthesis. Report on 333 cases. Urology, 42: 305, 1993.
    • (1993) Urology , vol.42 , pp. 305
    • Randrup, E.1    Wilson, S.2    Mobley, D.3    Suarez, G.4    Mekras, G.5    Baum, N.6
  • 10
  • 11
    • 0024573283 scopus 로고
    • Radiology of penile prostheses
    • Cohan, R. H., Dunnick, N. R. and Carson, C. C.: Radiology of penile prostheses. AJR, 152: 925, 1989.
    • (1989) AJR , vol.152 , pp. 925
    • Cohan, R.H.1    Dunnick, N.R.2    Carson, C.C.3
  • 12
    • 0026544035 scopus 로고
    • Patient and partner satisfaction with the AMS 700 penile prosthesis
    • McLaren, R. H. and Barrett, D. M.: Patient and partner satisfaction with the AMS 700 penile prosthesis. J. Urol., 147: 62, 1992.
    • (1992) J. Urol. , vol.147 , pp. 62
    • McLaren, R.H.1    Barrett, D.M.2
  • 13
    • 0028828309 scopus 로고
    • Long-term results of penile prosthetic implants
    • Lewis, R. W.: Long-term results of penile prosthetic implants. Urol. Clin. N. Amer., 22: 847, 1995.
    • (1995) Urol. Clin. N. Amer. , vol.22 , pp. 847
    • Lewis, R.W.1
  • 14
    • 0344814438 scopus 로고
    • Prevention and management of complications of penile prosthesis
    • lesson 6
    • Kaufman, J. J.: Prevention and management of complications of penile prosthesis. AUA Update Series, lesson 6, vol. 2, 1983.
    • (1983) AUA Update Series , vol.2
    • Kaufman, J.J.1
  • 15
    • 0028269484 scopus 로고
    • Penile prostheses for the management of the neuropathic bladder and sexual dysfunction in spinal cord injury patients: Long term follow up
    • Kimoto, Y. and Iwatsubo, E.: Penile prostheses for the management of the neuropathic bladder and sexual dysfunction in spinal cord injury patients: long term follow up. Paraplegia, 32: 336, 1994.
    • (1994) Paraplegia , vol.32 , pp. 336
    • Kimoto, Y.1    Iwatsubo, E.2
  • 16
    • 0343486694 scopus 로고    scopus 로고
    • Editorial comment
    • Montague, D. K.: Editorial comment. J. Urol., 155: 137, 1996.
    • (1996) J. Urol. , vol.155 , pp. 137
    • Montague, D.K.1
  • 18
    • 0028158037 scopus 로고
    • Self-contained, inflatable penile prosthesis: Magnetic resonance appearance
    • Levin, M. F., Munk, P. L., Vellet, A. D. and Chin, J. L.: Self-contained, inflatable penile prosthesis: magnetic resonance appearance. Australas. Rad., 38: 51, 1994.
    • (1994) Australas. Rad. , vol.38 , pp. 51
    • Levin, M.F.1    Munk, P.L.2    Vellet, A.D.3    Chin, J.L.4
  • 19
    • 0025737840 scopus 로고
    • MR imaging and biomedical implants, materials, and devices: An updated review
    • Shellock, F. G. and Curtis, J. S.: MR imaging and biomedical implants, materials, and devices: an updated review. Radiology, 180: 541, 1991.
    • (1991) Radiology , vol.180 , pp. 541
    • Shellock, F.G.1    Curtis, J.S.2
  • 20
    • 0029020476 scopus 로고
    • Cultures from genitourinary prosthesis ar reoperation: Questioning the role of Staphylococcus epidermidis in periprosthetic infection
    • Licht, M. R., Montague, D. K., Angermeier, K. W. and Lakin, M. M.: Cultures from genitourinary prosthesis ar reoperation: questioning the role of Staphylococcus epidermidis in periprosthetic infection. J. Urol., 154: 387, 1995.
    • (1995) J. Urol. , vol.154 , pp. 387
    • Licht, M.R.1    Montague, D.K.2    Angermeier, K.W.3    Lakin, M.M.4