메뉴 건너뛰기




Volumn 90, Issue 5-6, 2003, Pages 539-548

Determination of rate-constants as a method to describe passive expiration

Author keywords

Compartment models; Rate constants; Relaxed expiration; Respiratory system; System identification

Indexed keywords

ARTICLE; ARTIFICIAL VENTILATION; CALCULATION; CLINICAL ARTICLE; CONTROLLED STUDY; ENERGY TRANSFER; EXPIRATORY FLOW RATE; GAS DIFFUSION; HUMAN; LUNG GAS EXCHANGE; LUNG VOLUME; MATHEMATICAL COMPUTING; PLETHYSMOGRAPHY; PRIORITY JOURNAL; RELIABILITY; REPRODUCIBILITY; STATISTICAL SIGNIFICANCE; VISCOELASTICITY;

EID: 0344668740     PISSN: 14396319     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00421-003-0903-6     Document Type: Article
Times cited : (1)

References (23)
  • 1
    • 0023264256 scopus 로고
    • Impedance and relative displacements of relaxed chest wall up to 4. Hz
    • Barnas GM, Yoshino K, Loring SH, Mead J (1987) Impedance and relative displacements of relaxed chest wall up to 4 Hz. J Appl Physiol 62:71-81
    • (1987) J. Appl. Physiol. , vol.62 , pp. 71-81
    • Barnas, G.M.1    Yoshino, K.2    Loring, S.H.3    Mead, J.4
  • 4
    • 0023936579 scopus 로고
    • A theoretical analysis of interrupter technique for measuring respiratory mechanics
    • Bates JHT, Baconnier P, Milic-Emili J (1988) A theoretical analysis of interrupter technique for measuring respiratory mechanics. J Appl Physiol 64:2204-2214
    • (1988) J. Appl. Physiol. , vol.64 , pp. 2204-2214
    • Bates, J.H.T.1    Baconnier, P.2    Milic-Emili, J.3
  • 10
    • 0014825610 scopus 로고
    • A new approach to variable metric algorithms
    • Fletcher R (1970) A new approach to variable metric algorithms. Comput J 13:317-322
    • (1970) Comput. J. , vol.13 , pp. 317-322
    • Fletcher, R.1
  • 11
    • 0014753121 scopus 로고
    • Pressure-volume data of cat lung interpreted by a plastoelastic, linear viscoelastic model
    • Hildebrandt J (1970) Pressure-volume data of cat lung interpreted by a plastoelastic, linear viscoelastic model. J Appl Physiol 28:365-372
    • (1970) J. Appl. Physiol. , vol.28 , pp. 365-372
    • Hildebrandt, J.1
  • 12
    • 0021264888 scopus 로고
    • Accuracy of tidal volume, lung volume, and flow measurements by inductance vest in COPD patients
    • Hudgel DW, Capehart M, Johnson B, Hill P, Robertson D (1984) Accuracy of tidal volume, lung volume, and flow measurements by inductance vest in COPD patients. J Appl Physiol 56:1659-1665
    • (1984) J. Appl. Physiol. , vol.56 , pp. 1659-1665
    • Hudgel, D.W.1    Capehart, M.2    Johnson, B.3    Hill, P.4    Robertson, D.5
  • 13
    • 0004197269 scopus 로고
    • MINUIT - A system for function minimization and analysis of the parameter errors and correlations. Write-up adapted from CERN/DD internal report 75/20
    • CERN Computer Centre, Geneva
    • James F, Roos M (1976) MINUIT - A system for function minimization and analysis of the parameter errors and correlations. Write-up adapted from CERN/DD internal report 75/20. CERN Computer Centre, Geneva
    • (1976)
    • James, F.1    Roos, M.2
  • 14
    • 0344906718 scopus 로고
    • Determination of the rate-constants of a two-compartment model in order to characterize the respiratory system
    • Peniscola, Spain
    • Locchi F, Chelucci G-L (1991) Determination of the rate-constants of a two-compartment model in order to characterize the respiratory system. Proceedings of the IV International Symposium on Biomedical Engineering. Peniscola, Spain, pp 437-438
    • (1991) Proceedings of the IV International Symposium on Biomedical Engineering , pp. 437-438
    • Locchi, F.1    Chelucci, G.-L.2
  • 15
    • 0028357450 scopus 로고
    • A synthesis of the Otis, Mead, and Mount mechanical respiratory models
    • Lorino AM, Lorino H, Harf A (1994) A synthesis of the Otis, Mead, and Mount mechanical respiratory models. Respir Physiol 97:123-133
    • (1994) Respir. Physiol. , vol.97 , pp. 123-133
    • Lorino, A.M.1    Lorino, H.2    Harf, A.3
  • 16
    • 0000544497 scopus 로고
    • The ventilation flow resistance and compliance of rat lungs
    • Mount LE (1955) The ventilation flow resistance and compliance of rat lungs. J Physiol (Lond) 127:157-167
    • (1955) J. Physiol. (Lond) , vol.127 , pp. 157-167
    • Mount, L.E.1
  • 17
    • 0000238336 scopus 로고
    • A simplex method for function minimization
    • Nelder JA, Mead R (1965) A simplex method for function minimization. Comput J 7:308-313
    • (1965) Comput. J. , vol.7 , pp. 308-313
    • Nelder, J.A.1    Mead, R.2
  • 19
    • 0028859306 scopus 로고
    • Modelling the mechanical effects of tracheal tubes in normal subjects
    • Rocco PRM, Zin WA (1995) Modelling the mechanical effects of tracheal tubes in normal subjects. Eur Respir J 8:121-126
    • (1995) Eur. Respir. J. , vol.8 , pp. 121-126
    • Rocco, P.R.M.1    Zin, W.A.2
  • 20
    • 0025752254 scopus 로고
    • Two-compartment modelling of respiratory system mechanics at low frequencies: Gas redistribution or tissue rheology?
    • Similowski T, Bates JHT (1991) Two-compartment modelling of respiratory system mechanics at low frequencies: gas redistribution or tissue rheology? Eur Respir J 4:353-358
    • (1991) Eur. Respir. J. , vol.4 , pp. 353-358
    • Similowski, T.1    Bates, J.H.T.2
  • 21
    • 0025833198 scopus 로고
    • A non-linear viscoelastic model of lung tissue mechanics
    • Suki B, Bates JHT (1991) A non-linear viscoelastic model of lung tissue mechanics. J Appl Physiol 71:826-833
    • (1991) J. Appl. Physiol. , vol.71 , pp. 826-833
    • Suki, B.1    Bates, J.H.T.2
  • 22
    • 0023930574 scopus 로고
    • Influence of collateral ventilation on single-breath washout curves
    • Tomioka S, Kubo S, Guy HJB, Prisk GK (1988) Influence of collateral ventilation on single-breath washout curves. J Appl Physiol 64:429-434
    • (1988) J. Appl. Physiol. , vol.64 , pp. 429-434
    • Tomioka, S.1    Kubo, S.2    Guy, H.J.B.3    Prisk, G.K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.