메뉴 건너뛰기




Volumn 76, Issue 911, 2003, Pages 788-791

Contrast-to-noise ratio of multiple slice spin lock technique: Prospects for liver imaging

Author keywords

[No Author keywords available]

Indexed keywords

ABDOMEN; ADIPOSE TISSUE; ADULT; AGED; ARTICLE; ARTIFACT; BIOMEDICAL ENGINEERING; BIOMEDICAL TECHNOLOGY ASSESSMENT; CALCULATION; CLINICAL TRIAL; DIAGNOSTIC PROCEDURE; FEMALE; HUMAN; HUMAN EXPERIMENT; HUMAN TISSUE; LIVER; LIVER SLICE; MALE; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; RADIOFREQUENCY; RELAXATION TIME; SPIN LOCK NUCLEAR MAGNETIC RESONANCE IMAGING; SPLEEN; TISSUE SLICE; VOLUNTEER;

EID: 0344530448     PISSN: 00071285     EISSN: None     Source Type: Journal    
DOI: 10.1259/bjr/28705135     Document Type: Article
Times cited : (5)

References (15)
  • 3
    • 0031403698 scopus 로고    scopus 로고
    • T1ρ dispersion imaging of head and neck tumors: A comparison to spin lock and magnetization transfer techniques
    • Markkola AT, Aronen HJ, Paavonen T, Hopsu E, Sipilä LM, Tanttu JI, et al. T1ρ dispersion imaging of head and neck tumors: A comparison to spin lock and magnetization transfer techniques. J Magn Reson Imaging 1997;7:873-9.
    • (1997) J Magn Reson Imaging , vol.7 , pp. 873-879
    • Markkola, A.T.1    Aronen, H.J.2    Paavonen, T.3    Hopsu, E.4    Sipilä, L.M.5    Tanttu, J.I.6
  • 4
    • 0029665947 scopus 로고    scopus 로고
    • T1ρ relaxation and its application to MR histology
    • Engelhardt RT, Johnson GA. T1ρ relaxation and its application to MR histology. Magn Res Med 1996;35:781-6.
    • (1996) Magn Res Med , vol.35 , pp. 781-786
    • Engelhardt, R.T.1    Johnson, G.A.2
  • 5
    • 0023574349 scopus 로고
    • Radiofrequency penetration and absorption in the human body: Limitations to high-field whole-body nuclear magnetic resonance imaging
    • Röschmann P. Radiofrequency penetration and absorption in the human body: Limitations to high-field whole-body nuclear magnetic resonance imaging. Med Phys 1987;14:922-31.
    • (1987) Med Phys , vol.14 , pp. 922-931
    • Röschmann, P.1
  • 6
    • 0032129166 scopus 로고    scopus 로고
    • Standing-wave and RF penetration artifacts caused by elliptic geometry: An electrodynamic analysis of MRI
    • Sled JG, Pike GB. Standing-wave and RF penetration artifacts caused by elliptic geometry: An electrodynamic analysis of MRI. IEEE Trans Med Imag 1998;17:653-62.
    • (1998) IEEE Trans Med Imag , vol.17 , pp. 653-662
    • Sled, J.G.1    Pike, G.B.2
  • 8
    • 0344548989 scopus 로고
    • Differentiation of hepatic hemangiomas and metastases with multiple slice spin lock MR imaging
    • Halavaara JT, Lamminen AE, Bondestam S, Sepponem RE, Tanttu JI. Differentiation of hepatic hemangiomas and metastases with multiple slice spin lock MR imaging. Br J Radiol 1995;81:395-403.
    • (1995) Br J Radiol , vol.81 , pp. 395-403
    • Halavaara, J.T.1    Lamminen, A.E.2    Bondestam, S.3    Sepponem, R.E.4    Tanttu, J.I.5
  • 9
    • 0021152307 scopus 로고
    • Review of normal tissue hydrogen relaxation times and relaxation mechanisms from 1-100Hz: Dependence on tissue type, NMR frequency, temperature, species, excision, and age
    • Bottomley PA, Foster TH, Argersinger RE, Pfeifer LM. Review of normal tissue hydrogen relaxation times and relaxation mechanisms from 1-100Hz: Dependence on tissue type, NMR frequency, temperature, species, excision, and age. Med Phys 1984;11:425-48.
    • (1984) Med Phys , vol.11 , pp. 425-448
    • Bottomley, P.A.1    Foster, T.H.2    Argersinger, R.E.3    Pfeifer, L.M.4
  • 10
    • 0000949403 scopus 로고
    • Rotating frame and magnetization transfer
    • In: Stark DD, Bradley WG Jr, editors; St. Louis: Mosby-Year Boon, Inc
    • Sepponen RE. Rotating frame and magnetization transfer. Magnetic Resonance Imaging, 2nd edn. In: Stark DD, Bradley WG Jr, editors. 1992;204-18.
    • (1992) Magnetic Resonance Imaging, 2nd edn , pp. 204-218
    • Sepponen, R.E.1
  • 12
    • 0030614783 scopus 로고    scopus 로고
    • T1ρ of protein solutions at very low fields: Dependence on molecular weight, concentration, and structures
    • Virta A, Komu M, Kormano M. T1ρ of protein solutions at very low fields: Dependence on molecular weight, concentration, and structures. Magn Res Med 1997;37:53-7.
    • (1997) Magn Res Med , vol.37 , pp. 53-57
    • Virta, A.1    Komu, M.2    Kormano, M.3
  • 13
    • 0021247973 scopus 로고
    • Trace elements in human liver using quality control in the complete analytical process
    • Zeisler R, Harrison SH, Wise SA. Trace elements in human liver using quality control in the complete analytical process. Biol Trace Ele Res 1984;6:31-49.
    • (1984) Biol Trace Ele Res , vol.6 , pp. 31-49
    • Zeisler, R.1    Harrison, S.H.2    Wise, S.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.