메뉴 건너뛰기




Volumn 30, Issue 11, 2003, Pages 2897-2903

Automatic post-implant needle reconstruction algorithm to characterize and improve implant robustness analyses

Author keywords

Needle reconstruction; Post implant; Prostate brachytherapy; Seed migration; Seed misplacement

Indexed keywords

ONCOLOGY; QUALITY CONTROL; RADIOTHERAPY; SIMULATED ANNEALING; UROLOGY;

EID: 0344393793     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.1617480     Document Type: Article
Times cited : (10)

References (19)
  • 1
    • 0034562790 scopus 로고    scopus 로고
    • The combined use of the natural and the cumulative dose-volume histograms in planning and evaluation of permanent prostatic seed implants
    • M. A. Moerland, R. van der Laars, R. W. Luthmann, H. K. Wijrdeman, and J. J. Battermann, "The combined use of the natural and the cumulative dose-volume histograms in planning and evaluation of permanent prostatic seed implants," Int. J. Radiat. Oncol., Biol., Phys. 57, 279-284 (2000).
    • (2000) Int. J. Radiat. Oncol., Biol., Phys. , vol.57 , pp. 279-284
    • Moerland, M.A.1    Van Der Laars, R.2    Luthmann, R.W.3    Wijrdeman, H.K.4    Battermann, J.J.5
  • 2
    • 0032527941 scopus 로고    scopus 로고
    • Edema associated with I-125 or Pd-103 prostate brachytherapy and its impact on postimplant dosimetry: An analysis based on serial ct acquisition
    • F. M. Waterman, N. Yue, B. W. Corn, and A. P. Dicker. "Edema associated with I-125 or Pd-103 prostate brachytherapy and its impact on postimplant dosimetry: an analysis based on serial ct acquisition," Int. J. Radiat. Oncol., Biol., Phys. 41, 1069-1077 (1998).
    • (1998) Int. J. Radiat. Oncol., Biol., Phys. , vol.41 , pp. 1069-1077
    • Waterman, F.M.1    Yue, N.2    Corn, B.W.3    Dicker, A.P.4
  • 3
    • 0033976043 scopus 로고    scopus 로고
    • The American brachytherapy society recommendations for permanent prostate brachytherapy postimplant dosimetric analysis
    • S. Nag, W. Bice, K. DeWyngaert, B. Prestidge, R. Stock, and Y. Yu, "The American brachytherapy society recommendations for permanent prostate brachytherapy postimplant dosimetric analysis," Int. J. Radiat. Oncol., Biol., Phys. 46, 221-230 (2000).
    • (2000) Int. J. Radiat. Oncol., Biol., Phys. , vol.46 , pp. 221-230
    • Nag, S.1    Bice, W.2    DeWyngaert, K.3    Prestidge, B.4    Stock, R.5    Yu, Y.6
  • 4
    • 0032753788 scopus 로고    scopus 로고
    • Permanent prostate seed implant brachytheraoy: Report of the American Association of Physicists in Medicine Task Group No. 64
    • Y. Yu, L. L. Anderson, Z. Li, D. E. Mellenberg, R. Nath, M. C. Schell, F. M. Waterman, A. Wu, and J. C. Blasko, "Permanent prostate seed implant brachytheraoy: Report of the American Association of Physicists in Medicine Task Group No. 64," Med. Phys. 26, 2054-2076 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 2054-2076
    • Yu, Y.1    Anderson, L.L.2    Li, Z.3    Mellenberg, D.E.4    Nath, R.5    Schell, M.C.6    Waterman, F.M.7    Wu, A.8    Blasko, J.C.9
  • 6
    • 0032850621 scopus 로고    scopus 로고
    • Monte Carlo simulations of prostate implants to improve dosimetry and compare planning methods
    • R. Taschereau, J. Roy, and J. Pouliot, "Monte Carlo simulations of prostate implants to improve dosimetry and compare planning methods," Med. Phys. 26, 1952-1959 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 1952-1959
    • Taschereau, R.1    Roy, J.2    Pouliot, J.3
  • 7
    • 26444479778 scopus 로고
    • Optimisation by simulated annealing
    • C. D. Kirkpatrick, S. Gelatt, and M. P. Vecchi, "Optimisation by simulated annealing," Science 33, 671-683 (1983).
    • (1983) Science , vol.33 , pp. 671-683
    • Kirkpatrick, C.D.1    Gelatt, S.2    Vecchi, M.P.3
  • 8
    • 33646627294 scopus 로고    scopus 로고
    • An automatic post-implant needle reconstruction algorithm to characterize and improve the implant planning technique
    • abstract
    • L. Archambault and L. Beaulieu, "An automatic post-implant needle reconstruction algorithm to characterize and improve the implant planning technique." Med. Phys. 29, 1357 (2002) (abstract).
    • (2002) Med. Phys. , vol.29 , pp. 1357
    • Archambault, L.1    Beaulieu, L.2
  • 9
    • 0035889297 scopus 로고    scopus 로고
    • Dose homogeneity as a function of source activity in optimized I-125 prostate implant treatment plans
    • D. D. Souza and R. R. Meyer, "Dose homogeneity as a function of source activity in optimized I-125 prostate implant treatment plans," Int. J. Radiat. Oncol., Biol., Phys. 51, 1120-1130 (2001).
    • (2001) Int. J. Radiat. Oncol., Biol., Phys. , vol.51 , pp. 1120-1130
    • Souza, D.D.1    Meyer, R.R.2
  • 10
    • 0035183852 scopus 로고    scopus 로고
    • Automated seed detection and three-dimensional reconstruction i. seed localization from fluoroscopic images or radiographs
    • D. Tubic, A. Zaccarin, J. Pouliot, and L. Beaulieu, "Automated seed detection and three-dimensional reconstruction i. seed localization from fluoroscopic images or radiographs," Med. Phys. 28, 2265-2271 (2001).
    • (2001) Med. Phys. , vol.28 , pp. 2265-2271
    • Tubic, D.1    Zaccarin, A.2    Pouliot, J.3    Beaulieu, L.4
  • 11
    • 0030251339 scopus 로고    scopus 로고
    • Optimisation of permanent 125i prostate implant using fast simulated annealing
    • J. Pouliot, D. Tremblay, J. Roy, and S. Filice, "Optimisation of permanent 125i prostate implant using fast simulated annealing," Int. J. Radiat. Oncol., Biol., Phys. 36, 711-720 (1996).
    • (1996) Int. J. Radiat. Oncol., Biol., Phys. , vol.36 , pp. 711-720
    • Pouliot, J.1    Tremblay, D.2    Roy, J.3    Filice, S.4
  • 12
    • 0026760646 scopus 로고
    • Optimization of brachytherapy dose distributions by simulated annealing
    • R. S. Sloboda, "Optimization of brachytherapy dose distributions by simulated annealing," Med. Phys. 19, 955-964 (1992).
    • (1992) Med. Phys. , vol.19 , pp. 955-964
    • Sloboda, R.S.1
  • 15
    • 0035183853 scopus 로고    scopus 로고
    • Automated seed detection and three-dimensional reconstruction II. Reconstruction of permanent implants using simulated annealing
    • D. Tubic, A. Zaccarin, L. Beaulieu, and J. Pouliot, "Automated seed detection and three-dimensional reconstruction II. Reconstruction of permanent implants using simulated annealing," Med. Phys. 28, 2272-2279 (2001).
    • (2001) Med. Phys. , vol.28 , pp. 2272-2279
    • Tubic, D.1    Zaccarin, A.2    Beaulieu, L.3    Pouliot, J.4
  • 17
    • 0034213193 scopus 로고    scopus 로고
    • Dosimetric and volumetric criteria for selecting a source activity and a source type (125i or 103pd) in the presence of irregular seed placement in permanent prostate implant
    • C. Wuu, R. D. Ennis, P. B., Schiff, E. K. Lee. and M. Zaider, "Dosimetric and volumetric criteria for selecting a source activity and a source type (125i or 103pd) in the presence of irregular seed placement in permanent prostate implant," Int. J. Radiat. Oncol., Biol., Phys. 47, 815-820 (2000).
    • (2000) Int. J. Radiat. Oncol., Biol., Phys. , vol.47 , pp. 815-820
    • Wuu, C.1    Ennis, R.D.2    Schiff, P.B.3    Lee, E.K.4    Zaider, M.5
  • 18
    • 0035869729 scopus 로고    scopus 로고
    • On the determination of an effective planning volume for permanent prostate implants
    • E. K. Lee and M. Zaider, "On the determination of an effective planning volume for permanent prostate implants," Int. J. Radiat. Oncol., Biol., Phys. 49, 1197-1206 (2001).
    • (2001) Int. J. Radiat. Oncol., Biol., Phys. , vol.49 , pp. 1197-1206
    • Lee, E.K.1    Zaider, M.2
  • 19
    • 0034088966 scopus 로고    scopus 로고
    • Comparison of seed loading approaches in prostate brachytherapy
    • W. M. Butler, G. S. Merrick, J. H. Lief, and A. T. Dorsey, "Comparison of seed loading approaches in prostate brachytherapy," Med. Phys. 27, 381-392 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 381-392
    • Butler, W.M.1    Merrick, G.S.2    Lief, J.H.3    Dorsey, A.T.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.