1
-
-
0030944622
-
Dosimeter gel and MR imaging for verification of calculated dose distributions in clinical radiation therapy
-
Johansson S.A., Magnusson P., Fransson A., Olsson L.E., Christoffersson J.O., Montelius A., Mattsson S. Dosimeter gel and MR imaging for verification of calculated dose distributions in clinical radiation therapy. Acta Oncol. 36:1997;283-290.
-
(1997)
Acta Oncol
, vol.36
, pp. 283-290
-
-
Johansson, S.A.1
Magnusson, P.2
Fransson, A.3
Olsson, L.E.4
Christoffersson, J.O.5
Montelius, A.6
Mattsson, S.7
-
2
-
-
2642703476
-
Improvement in absorbed dose measurements for external radiation therapy using ferrous dosimeter gel and MR imaging (FeMRI)
-
Johansson Bäck S.Å., Magnusson P., Fransson A., Olsson L.E., Montelius A., Holmberger O., Andreo P., Mattsson S. Improvement in absorbed dose measurements for external radiation therapy using ferrous dosimeter gel and MR imaging (FeMRI). Phys. Med. Biol. 43:1998;261-276.
-
(1998)
Phys. Med. Biol.
, vol.43
, pp. 261-276
-
-
Johansson Bäck, S.Å.1
Magnusson, P.2
Fransson, A.3
Olsson, L.E.4
Montelius, A.5
Holmberger, O.6
Andreo, P.7
Mattsson, S.8
-
3
-
-
0021232591
-
Measurement of radiation dose distributions by nuclear magnetic resonance (NMR) imaging
-
Gore J.C., Kang Y.S., Schulz R.J. Measurement of radiation dose distributions by nuclear magnetic resonance (NMR) imaging. Phys. Med. Biol. 29:1984;1189-1197.
-
(1984)
Phys. Med. Biol.
, vol.29
, pp. 1189-1197
-
-
Gore, J.C.1
Kang, Y.S.2
Schulz, R.J.3
-
4
-
-
0025203008
-
MR imaging of absorbed dose distributions for radiotherapy using ferrous sulphate gels
-
Olsson L.E., Fransson A., Ericsson A., Mattsson S. MR imaging of absorbed dose distributions for radiotherapy using ferrous sulphate gels. Phys. Med. Biol. 35:1990;1623-1631.
-
(1990)
Phys. Med. Biol.
, vol.35
, pp. 1623-1631
-
-
Olsson, L.E.1
Fransson, A.2
Ericsson, A.3
Mattsson, S.4
-
5
-
-
0025866717
-
Dose-response characteristics of a ferrous-sulphate-doped gelatin system for determining radiation absorbed dose distributions by magnetic resonance imaging (Fe MRI)
-
Hazle J.D., Hefner L., Nyerick C.E., Wilson L., Boyer A.L. Dose-response characteristics of a ferrous-sulphate-doped gelatin system for determining radiation absorbed dose distributions by magnetic resonance imaging (Fe MRI). Phys. Med. Biol. 36:1991;1117-1125.
-
(1991)
Phys. Med. Biol.
, vol.36
, pp. 1117-1125
-
-
Hazle, J.D.1
Hefner, L.2
Nyerick, C.E.3
Wilson, L.4
Boyer, A.L.5
-
6
-
-
0027997190
-
Dose distribution measurements in superficial X-ray beams using NMR dosimetry
-
Kron T., Pope J.M. Dose distribution measurements in superficial X-ray beams using NMR dosimetry. Phys. Med. Biol. 39:1994;1337-1349.
-
(1994)
Phys. Med. Biol.
, vol.39
, pp. 1337-1349
-
-
Kron, T.1
Pope, J.M.2
-
7
-
-
0030058455
-
Measurement of dynamic wedge angles and beam profiles by means of MRI ferrous sulphate gel dosimetry
-
Bengtsson M., Furre T., Rodal J., Skretting A., Olsen D.R. Measurement of dynamic wedge angles and beam profiles by means of MRI ferrous sulphate gel dosimetry. Phys. Med. Biol. 41:1996;269-277.
-
(1996)
Phys. Med. Biol.
, vol.41
, pp. 269-277
-
-
Bengtsson, M.1
Furre, T.2
Rodal, J.3
Skretting, A.4
Olsen, D.R.5
-
10
-
-
0031004809
-
Determination of 3D dose distribution from intracavitary brachytherapy of cervical cancer by MRI of irradiated ferrous sulphate gel
-
Knutsen B.H., Skretting A., Hellebust T.P., Olsen D.R. Determination of 3D dose distribution from intracavitary brachytherapy of cervical cancer by MRI of irradiated ferrous sulphate gel. Radiother. Oncol. 43:1997;219-227.
-
(1997)
Radiother. Oncol.
, vol.43
, pp. 219-227
-
-
Knutsen, B.H.1
Skretting, A.2
Hellebust, T.P.3
Olsen, D.R.4
-
12
-
-
0026048002
-
A new dosimeter based on ferrous sulphate solution and agarose gel
-
Olsson L.E., Appleby A., Sommer J. A new dosimeter based on ferrous sulphate solution and agarose gel. Appl. Radiat. Isot. 42:1991;1081-1086.
-
(1991)
Appl. Radiat. Isot.
, vol.42
, pp. 1081-1086
-
-
Olsson, L.E.1
Appleby, A.2
Sommer, J.3
-
13
-
-
0344857140
-
The Raven MRI teaching file
-
R.B. Lufkin, W.G.J. Bradley, & B. Brant-Zawadzki. New York: Raven
-
Hendrick R.E. The Raven MRI teaching file. Lufkin R.B., Bradley W.G.J., Brant-Zawadzki B. MRI principles and artifacts . 1993;2-6 Raven, New York.
-
(1993)
MRI: Principles and Artifacts
, pp. 2-6
-
-
Hendrick, R.E.1
-
14
-
-
0345250090
-
PMRelax. An image processing software designed for complete 3D-evaluation in MRI gel dosimetry
-
Magnusson, P.; Olsson, L.E. PMRelax. An image processing software designed for complete 3D-evaluation in MRI gel dosimetry. Abstract of the AAPM:41; 1999.
-
(1999)
Abstract of the AAPM
, pp. 41
-
-
Magnusson, P.1
Olsson, L.E.2
-
15
-
-
0028864141
-
Correcting for rf inhomogeneities in multiecho pulse sequence MRI dosimetry
-
Duzenli C., Robinson D. Correcting for rf inhomogeneities in multiecho pulse sequence MRI dosimetry. Med. Phys. 22:1995;1645-1650.
-
(1995)
Med. Phys.
, vol.22
, pp. 1645-1650
-
-
Duzenli, C.1
Robinson, D.2
-
17
-
-
0031974199
-
A simple method for investigating the effects of non-uniformity of radiofrequency transmission and radiofrequency reception in MRI
-
Barker G.J., Simmons A., Arridge S.R., Tofts P.S. A simple method for investigating the effects of non-uniformity of radiofrequency transmission and radiofrequency reception in MRI. Br. J. Radiol. 71:1998;59-67.
-
(1998)
Br. J. Radiol.
, vol.71
, pp. 59-67
-
-
Barker, G.J.1
Simmons, A.2
Arridge, S.R.3
Tofts, P.S.4
-
18
-
-
0021323541
-
Spin lattice relaxation time measurements in two-dimensional nuclear magnetic resonance imaging: Corrections for plane selection and pulse sequence
-
Rosen B.R., Pykett I.L., Brady T.J. Spin lattice relaxation time measurements in two-dimensional nuclear magnetic resonance imaging Corrections for plane selection and pulse sequence . J. Comput. Assist. Tomogr. 8:1984;195-199.
-
(1984)
J. Comput. Assist. Tomogr.
, vol.8
, pp. 195-199
-
-
Rosen, B.R.1
Pykett, I.L.2
Brady, T.J.3
-
19
-
-
0021912455
-
Strategies and tactics in NMR imaging relaxation time measurements. I. Minimizing relaxation time errors due to image noise-the ideal case
-
Kurland R.J. Strategies and tactics in NMR imaging relaxation time measurements. I. Minimizing relaxation time errors due to image noise-the ideal case. Magn. Reson. Med. 2:1985;136-158.
-
(1985)
Magn. Reson. Med.
, vol.2
, pp. 136-158
-
-
Kurland, R.J.1
-
20
-
-
0005852122
-
1 calculations in multiple-echo sequences with imperfect pulses
-
1 calculations in multiple-echo sequences with imperfect pulses. Concepts Magn. Res. 11:1999;29-49.
-
(1999)
Concepts Magn. Res.
, vol.11
, pp. 29-49
-
-
Kingsley, P.B.1
-
21
-
-
0032428719
-
The radiation induced magnetic resonance image intensity change provides a more efficient three-dimensional dose measurement in MRI-Fricke-agarose gel dosimetry
-
Chu W.C., Guo W.Y., Wu M.C., Chung W.Y., Pan D.H. The radiation induced magnetic resonance image intensity change provides a more efficient three-dimensional dose measurement in MRI-Fricke-agarose gel dosimetry. Med. Phys. 25:1998;2326-2332.
-
(1998)
Med. Phys.
, vol.25
, pp. 2326-2332
-
-
Chu, W.C.1
Guo, W.Y.2
Wu, M.C.3
Chung, W.Y.4
Pan, D.H.5
|