메뉴 건너뛰기




Volumn 42, Issue 16, 1999, Pages 3037-3046

Control of fouling in a spirally-ribbed water chilled tube with electronic anti-fouling technology

Author keywords

[No Author keywords available]

Indexed keywords

ELECTRONIC EQUIPMENT; FOULING; HEAT EXCHANGERS; HEAT TRANSFER COEFFICIENTS; TUBES (COMPONENTS);

EID: 0344131374     PISSN: 00179310     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0017-9310(99)00026-5     Document Type: Article
Times cited : (29)

References (16)
  • 3
    • 0000220654 scopus 로고    scopus 로고
    • Enhancement of heat transfer and fouling mitigation
    • Irvine T.F. Jr et al. New York: Academic Press
    • Sommerscales E.F.C., Bergles A.E. Enhancement of heat transfer and fouling mitigation. Irvine T.F. Jr, et al. Advances in Heat Transfer. vol. 30:1997;197-253 Academic Press, New York.
    • (1997) Advances in Heat Transfer , vol.30 , pp. 197-253
    • Sommerscales, E.F.C.1    Bergles, A.E.2
  • 7
    • 0031256911 scopus 로고    scopus 로고
    • Theory of electronic descaling technology of control precipitation fouling in heat exchangers
    • Cho Y.I., Fan C., Choi B.G. Theory of electronic descaling technology of control precipitation fouling in heat exchangers. Int. Comm. Heat Mass Transfer. 24:1997;747-756.
    • (1997) Int. Comm. Heat Mass Transfer , vol.24 , pp. 747-756
    • Cho, Y.I.1    Fan, C.2    Choi, B.G.3
  • 8
    • 0010273493 scopus 로고    scopus 로고
    • Use of electronic descaling technology to control precipitation fouling in plate-and-frame heat exchangers
    • R.K. Shah. New York: Begell House
    • Cho Y.I., Choi B.G., Drazner B.J. Use of electronic descaling technology to control precipitation fouling in plate-and-frame heat exchangers. Shah R.K., Compact Heat Exchangers for the Process Industries. 1997;267-273 Begell House, New York.
    • (1997) Compact Heat Exchangers for the Process Industries , pp. 267-273
    • Cho, Y.I.1    Choi, B.G.2    Drazner, B.J.3
  • 9
    • 0032169119 scopus 로고    scopus 로고
    • Electronic anti-fouling technology to mitigate precipitation fouling in plate-and-frame heat exchangers
    • Cho Y.I., Choi B.G., Drazner B.J. Electronic anti-fouling technology to mitigate precipitation fouling in plate-and-frame heat exchangers. Int. J. Heat Mass Transfer. 41:1998;2565-2571.
    • (1998) Int. J. Heat Mass Transfer , vol.41 , pp. 2565-2571
    • Cho, Y.I.1    Choi, B.G.2    Drazner, B.J.3
  • 10
    • 0032077779 scopus 로고    scopus 로고
    • Effect of fouling on temperature measurement error and a solution
    • Cho Y.I., Choi B.G. Effect of fouling on temperature measurement error and a solution. Journal of Heat Transfer. 120:1998;525-528.
    • (1998) Journal of Heat Transfer , vol.120 , pp. 525-528
    • Cho, Y.I.1    Choi, B.G.2
  • 11
    • 0344327040 scopus 로고    scopus 로고
    • Validation of an electronic anti-fouling technology in a single-tube heat exchanger
    • Cho Y.I., Choi B.G. Validation of an electronic anti-fouling technology in a single-tube heat exchanger. International Journal of Heat and Mass Transfer. 42:1998;1491-1499.
    • (1998) International Journal of Heat and Mass Transfer , vol.42 , pp. 1491-1499
    • Cho, Y.I.1    Choi, B.G.2
  • 12
    • 0017926379 scopus 로고
    • Scale nucleation on a heat transfer surface and its prevention
    • Troup D.H., Richardson J.A. Scale nucleation on a heat transfer surface and its prevention. Chem. Eng. Comm. 2:1978;167-180.
    • (1978) Chem. Eng. Comm. , vol.2 , pp. 167-180
    • Troup, D.H.1    Richardson, J.A.2
  • 16
    • 0027509022 scopus 로고
    • Crystallization fouling in plate heat exchangers
    • Bansal B., Müller-Steinhagen H. Crystallization fouling in plate heat exchangers. J. of Heat Transfer. 115:1993;584-591.
    • (1993) J. of Heat Transfer , vol.115 , pp. 584-591
    • Bansal, B.1    Müller-Steinhagen, H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.