메뉴 건너뛰기




Volumn 49, Issue 2, 1998, Pages 191-196

Monte Carlo calculation of the dose distributions of two 106Ru eye applicators

Author keywords

Brachytherapy; Dosimetry; Eye melanoma; Monte Carlo; Ruthenium 106

Indexed keywords

RUBIDIUM; RUBIDIUM 106; UNCLASSIFIED DRUG;

EID: 0344097331     PISSN: 01678140     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0167-8140(98)00095-4     Document Type: Article
Times cited : (27)

References (17)
  • 1
    • 0025730909 scopus 로고
    • Monte Carlo techniques in medical radiation physics
    • Andreo P. Monte Carlo techniques in medical radiation physics. Phys. Med. Biol. 36:1991;861-920.
    • (1991) Phys. Med. Biol. , vol.36 , pp. 861-920
    • Andreo, P.1
  • 3
    • 58149210333 scopus 로고
    • PENELOPE: An algorithm for Monte Carlo simulation of the penetration and energy loss of electrons and positrons in matter
    • Baró J., Sempau J., Fernández-Varea J.M., Salvat F. PENELOPE: an algorithm for Monte Carlo simulation of the penetration and energy loss of electrons and positrons in matter. Nucl. Instrum. Methods B. 100:1995;31-46.
    • (1995) Nucl. Instrum. Methods B , vol.100 , pp. 31-46
    • Baró, J.1    Sempau, J.2    Fernández-Varea, J.M.3    Salvat, F.4
  • 5
    • 0025636013 scopus 로고
    • Determination of the dose distribution of an ophthalmic Ru-106 eye applicator with TLDs and eye phantom
    • Binder W., Chiari A., Aiginger H. Determination of the dose distribution of an ophthalmic Ru-106 eye applicator with TLDs and eye phantom. Rad. Prot. Dosimet. 34:1990;275-278.
    • (1990) Rad. Prot. Dosimet. , vol.34 , pp. 275-278
    • Binder, W.1    Chiari, A.2    Aiginger, H.3
  • 9
    • 0031052980 scopus 로고    scopus 로고
    • Theoretical calculations of dose distribution for beta-ray applicators
    • Hokkanen J., Heikkonen J., Holmberg P. Theoretical calculations of dose distribution for beta-ray applicators. Med. Phys. 24:1997;211-213.
    • (1997) Med. Phys. , vol.24 , pp. 211-213
    • Hokkanen, J.1    Heikkonen, J.2    Holmberg, P.3
  • 10
    • 0003852486 scopus 로고
    • Radionuclide transformations
    • ICRP Report 38. Oxford: Pergamon
    • ICRP Report 38. Radionuclide transformations. Energy and intensity of emissions. Oxford: Pergamon, 1983.
    • (1983) Energy and Intensity of Emissions
  • 11
    • 0025923029 scopus 로고
    • 106Ru eye applicators with a p-type silicon detector
    • 106Ru eye applicators with a p-type silicon detector. Phys. Med. Biol. 36:1991;963-972.
    • (1991) Phys. Med. Biol. , vol.36 , pp. 963-972
    • Lax, I.1
  • 12
  • 13
    • 0344505359 scopus 로고
    • 106Rh applicators of choroidal melanomas: Sixteen years experience
    • Berlin: Akademic
    • 106Rh applicators of choroidal melanomas: sixteen years experience. Fortschritte der Onkologie. Berlin: Akademic, 1983: 290-301.
    • (1983) Fortschritte Der Onkologie , pp. 290-301
    • Lommatzsch, P.1
  • 15
    • 0028556246 scopus 로고
    • Absorbed dose distribution measurements in brachytherapy using ferrous sulphate gel and magnetic resonance imaging
    • Olsen D.R., Hellesnes J. Absorbed dose distribution measurements in brachytherapy using ferrous sulphate gel and magnetic resonance imaging. Br. J. Rad. 67:1994;1121-1126.
    • (1994) Br. J. Rad. , vol.67 , pp. 1121-1126
    • Olsen, D.R.1    Hellesnes, J.2
  • 16
    • 0003410374 scopus 로고    scopus 로고
    • PENELOPE, an algorithm and computer code for Monte Carlo simulation of electron-photon showers
    • Madrid
    • Salvat F, Fernández-Varea JM, Baró J, Sempau J. PENELOPE, an algorithm and computer code for Monte Carlo simulation of electron-photon showers. CIEMAT Report n. 799. Madrid, 1996.
    • (1996) CIEMAT Report N. 799
    • Salvat, F.1    Fernández-Varea, J.M.2    Baró, J.3    Sempau, J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.