메뉴 건너뛰기




Volumn 48, Issue 22, 2003, Pages

Patient-specific planning for prevention of mechanical collisions during radiotherapy

Author keywords

[No Author keywords available]

Indexed keywords

COMPUTER PROGRAM LISTINGS; LINEAR ACCELERATORS; PATIENT TREATMENT; PLANNING;

EID: 0344035361     PISSN: 00319155     EISSN: None     Source Type: Journal    
DOI: 10.1088/0031-9155/48/22/N02     Document Type: Article
Times cited : (29)

References (10)
  • 1
    • 0034068527 scopus 로고    scopus 로고
    • A collision prevention software tool for complex three-dimensional isocentric set-ups
    • Beange I and Nisbet A 2000 A collision prevention software tool for complex three-dimensional isocentric set-ups Br. J. Radiol. 73 537-41
    • (2000) Br. J. Radiol. , vol.73 , pp. 537-541
    • Beange, I.1    Nisbet, A.2
  • 3
    • 0028093466 scopus 로고
    • Collision avoidance in computer optimized treatment-planning
    • Humm J L 1994 Collision avoidance in computer optimized treatment-planning Med. Phys. 21 1053-64
    • (1994) Med. Phys. , vol.21 , pp. 1053-1064
    • Humm, J.L.1
  • 5
    • 0345423100 scopus 로고    scopus 로고
    • Radiotherapy equipment - Coordinates movements and scales
    • International Electrotechnical Commission (IEC)
    • International Electrotechnical Commission (IEC) 1996 Radiotherapy equipment - coordinates movements and scales IEC Standard 1217
    • (1996) IEC Standard , pp. 1217
  • 7
    • 0019856668 scopus 로고
    • Solution to the treatment-planning problems using coordinate transformations
    • Siddon R L 1981 Solution to the treatment-planning problems using coordinate transformations Med. Phys. 8 766-74
    • (1981) Med. Phys. , vol.8 , pp. 766-774
    • Siddon, R.L.1
  • 8
    • 0034919039 scopus 로고    scopus 로고
    • Graphical treatment simulation and automated collision detection for conformal and stereotactic radiotherapy treatment-planning
    • Tsiakalos M F, Schrebmann E, Theodorou K and Kappas C 2001 Graphical treatment simulation and automated collision detection for conformal and stereotactic radiotherapy treatment-planning Med. Phys. 28 1359-63
    • (2001) Med. Phys. , vol.28 , pp. 1359-1363
    • Tsiakalos, M.F.1    Schrebmann, E.2    Theodorou, K.3    Kappas, C.4
  • 9
    • 25744437315 scopus 로고    scopus 로고
    • PANIC (Prevent Any Impending Collision): A 3D visualization and collision prevention software for complex 3D isocentric beam setups
    • Vakaet L, de Gersem W, de Meerleer G and de Neve W 1998 PANIC (Prevent Any Impending Collision): a 3D visualization and collision prevention software for complex 3D isocentric beam setups Radiother. Oncol. 48 S148
    • (1998) Radiother. Oncol. , vol.48
    • Vakaet, L.1    de Gersem, W.2    de Meerleer, G.3    de Neve, W.4
  • 10
    • 0027414262 scopus 로고
    • An optical system for measuring surface shapes for radiotherapy planning
    • Wilks R J 1993 An optical system for measuring surface shapes for radiotherapy planning Br. J. Radiol. 66 351-9
    • (1993) Br. J. Radiol. , vol.66 , pp. 351-359
    • Wilks, R.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.