-
1
-
-
0025039001
-
Prognostic value of radionuclide angiography in medically treated patients with coronary artery disease. A comparison of clinical and catheterization variables
-
Lee K. Pryor D, Pieper K, et al. Prognostic value of radionuclide angiography in medically treated patients with coronary artery disease. A comparison of clinical and catheterization variables. Circulation. 1990;82:1705-1717.
-
(1990)
Circulation
, vol.82
, pp. 1705-1717
-
-
Lee, K.1
Pryor, D.2
Pieper, K.3
-
2
-
-
0344142816
-
Radionuclide angiocardiography in patients with coronary artery disease
-
Zaret BL, Beller GA, eds. St. Louis, MO: Mosby
-
Jones RH. Radionuclide angiocardiography in patients with coronary artery disease. In: Zaret BL, Beller GA, eds. Nuclear Cardiology: State of the Art and Future Directions. St. Louis, MO: Mosby; 1993:111-122.
-
(1993)
Nuclear Cardiology: State of the Art and Future Directions
, pp. 111-122
-
-
Jones, R.H.1
-
3
-
-
0344142814
-
Gated equilibrium blood pool imaging: Current role for diagnosis and prognosis in coronary artery disease
-
Zaret BL, Beller GA, eds. St. Louis, MO: Mosby
-
Bonow RO. Gated equilibrium blood pool imaging: current role for diagnosis and prognosis in coronary artery disease. In: Zaret BL, Beller GA, eds. Nuclear Cardiology: State of the Art and Future Directions. St. Louis, MO: Mosby; 1993:123-136.
-
(1993)
Nuclear Cardiology: State of the Art and Future Directions
, pp. 123-136
-
-
Bonow, R.O.1
-
4
-
-
0028807605
-
Automatic quantification of ejection fraction from gated myocardial perfusion SPECT
-
Germano G, Kiat H, Kavanagh PB, et al. Automatic quantification of ejection fraction from gated myocardial perfusion SPECT. J Nucl Med. 1995;36:2138-2147.
-
(1995)
J Nucl Med
, vol.36
, pp. 2138-2147
-
-
Germano, G.1
Kiat, H.2
Kavanagh, P.B.3
-
5
-
-
0030462552
-
Left ventricular ejection fraction from gated SPET myocardial perfusion studies: A method based on count rate density across the myocardial wall
-
Everaert H, Franken PR, Flamen P, Goris M, Momen A, Bossuyt A. Left ventricular ejection fraction from gated SPET myocardial perfusion studies: a method based on count rate density across the myocardial wall. Eur J Nucl Med. 1996;23:1628-1633.
-
(1996)
Eur J Nucl Med
, vol.23
, pp. 1628-1633
-
-
Everaert, H.1
Franken, P.R.2
Flamen, P.3
Goris, M.4
Momen, A.5
Bossuyt, A.6
-
6
-
-
0031031389
-
Assessment of left ventricular volume using ECG-gated SPECT with technetium-99m-MIBI and technetium-99m-tetrofosmin
-
Mochizuki T, Murase K, Tanaka H, Kondoh T, Hamamoto K, Tauxe WN. Assessment of left ventricular volume using ECG-gated SPECT with technetium-99m-MIBI and technetium-99m-tetrofosmin. J Nucl Med. 1997;38:53-57.
-
(1997)
J Nucl Med
, vol.38
, pp. 53-57
-
-
Mochizuki, T.1
Murase, K.2
Tanaka, H.3
Kondoh, T.4
Hamamoto, K.5
Tauxe, W.N.6
-
7
-
-
0030453611
-
Automation of gated tomographic left ventricular ejection fraction
-
Nichols K, DePuey G, Rozanski A. Automation of gated tomographic left ventricular ejection fraction. J Nucl Cardiol. 1996;3:475-482.
-
(1996)
J Nucl Cardiol
, vol.3
, pp. 475-482
-
-
Nichols, K.1
DePuey, G.2
Rozanski, A.3
-
8
-
-
0030071191
-
Left ventricular function in patients with coronary artery disease assessed by gated tomographic myocardial perfusion images: Comparison with assessment by contrast ventriculography and first-pass radionuclide angiography
-
Williams KA, Taillon LA. Left ventricular function in patients with coronary artery disease assessed by gated tomographic myocardial perfusion images: comparison with assessment by contrast ventriculography and first-pass radionuclide angiography. J Am Coll Cardiol. 1996;27:173-181.
-
(1996)
J Am Coll Cardiol
, vol.27
, pp. 173-181
-
-
Williams, K.A.1
Taillon, L.A.2
-
9
-
-
0027442739
-
Left ventricular ejection fraction assessed from gated technetium-99m-sestamibi SPECT
-
DePuey EG, Nichols K, Dobrinsky C. Left ventricular ejection fraction assessed from gated technetium-99m-sestamibi SPECT. J Nucl Med. 1993;34:1871-1876.
-
(1993)
J Nucl Med
, vol.34
, pp. 1871-1876
-
-
DePuey, E.G.1
Nichols, K.2
Dobrinsky, C.3
-
10
-
-
0025175322
-
Technetium-99m myocardial perfusion imaging agents and their relation to thallium-20
-
Berman D. Technetium-99m myocardial perfusion imaging agents and their relation to thallium-20. Am J Cardiol. 1990;66:1E-4E.
-
(1990)
Am J Cardiol
, vol.66
-
-
Berman, D.1
-
11
-
-
0030905195
-
Quantification of left ventricular function with thallium-201 and technetium-99m-sestamibi myocardial gated SPECT
-
Maunoury C, Chen CC, Chua KB, Thompson CJ. Quantification of left ventricular function with thallium-201 and technetium-99m-sestamibi myocardial gated SPECT. J Nucl Med. 1997;38:958-961.
-
(1997)
J Nucl Med
, vol.38
, pp. 958-961
-
-
Maunoury, C.1
Chen, C.C.2
Chua, K.B.3
Thompson, C.J.4
-
12
-
-
0030912582
-
Quantitative LVEF and qualitative regional function from gated thallium-201 perfusion SPECT
-
Germano G, Erel J, Kiat H, Kavanagh PB, Berman DS. Quantitative LVEF and qualitative regional function from gated thallium-201 perfusion SPECT. J Nucl Med. 1997;38:749-754.
-
(1997)
J Nucl Med
, vol.38
, pp. 749-754
-
-
Germano, G.1
Erel, J.2
Kiat, H.3
Kavanagh, P.B.4
Berman, D.S.5
-
13
-
-
0028072709
-
A semi-automated method for edge detection in the evaluation of left ventricular function using ECG-gated single-photon emission tomography
-
Yang KTA, Chen HD. A semi-automated method for edge detection in the evaluation of left ventricular function using ECG-gated single-photon emission tomography. Eur J Nucl Med. 1994;21:1206-1211.
-
(1994)
Eur J Nucl Med
, vol.21
, pp. 1206-1211
-
-
Yang, K.T.A.1
Chen, H.D.2
-
14
-
-
0029119748
-
Quantitative SPECT imaging: A review and recommendations by the focus committee of the Society of Nuclear Medicine Computer and Instrumentation Council
-
Rosenthal MS, Cullom J, Hawkins W, Moore SC, Tsui BMW, Yester M. Quantitative SPECT imaging: a review and recommendations by the focus committee of the Society of Nuclear Medicine Computer and Instrumentation Council. J Nucl Med. 1995;36:1489-1513.
-
(1995)
J Nucl Med
, vol.36
, pp. 1489-1513
-
-
Rosenthal, M.S.1
Cullom, J.2
Hawkins, W.3
Moore, S.C.4
Tsui, B.M.W.5
Yester, M.6
-
16
-
-
0030894375
-
Residual area at risk after anterior myocardial infarction: Are ST segment changes during coronary angioplasty a reliable indicator? A comparison with technetium 99m-labeled sestamibi single-photon emission computed tomography
-
Faraggi M, Steg PG, Francois D, et al. Residual area at risk after anterior myocardial infarction: are ST segment changes during coronary angioplasty a reliable indicator? A comparison with technetium 99m-labeled sestamibi single-photon emission computed tomography. J Nucl Cardiol. 1997;4:11-17.
-
(1997)
J Nucl Cardiol
, vol.4
, pp. 11-17
-
-
Faraggi, M.1
Steg, P.G.2
Francois, D.3
-
17
-
-
0029027853
-
Comparative study of three automatic programs of left ventricular ejection fraction evaluation
-
Véra P, Gardin I, Bok B. Comparative study of three automatic programs of left ventricular ejection fraction evaluation. Nucl Med Commun. 1995;16:667-674.
-
(1995)
Nucl Med Commun
, vol.16
, pp. 667-674
-
-
Véra, P.1
Gardin, I.2
Bok, B.3
-
18
-
-
0014265052
-
The use of single plane angiocardiograms for the calculation of left ventricular volume in man
-
Sandler H, Dodge HT. The use of single plane angiocardiograms for the calculation of left ventricular volume in man. Am Heart J. 1968;75:325-334.
-
(1968)
Am Heart J
, vol.75
, pp. 325-334
-
-
Sandler, H.1
Dodge, H.T.2
-
19
-
-
84908219488
-
Stastistical methods for assessing agreement between two methods of clinical measurement
-
Bland JM, Altman DG. Stastistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;i:307-310.
-
(1986)
Lancet
, vol.1
, pp. 307-310
-
-
Bland, J.M.1
Altman, D.G.2
-
20
-
-
0018957839
-
Increased lung uptake of thallium-201 during exercise myocardial imaging: Clinical, hemodynamic and angiographic implications in patients with coronary artery disease
-
Boucher CA, Zir LM, Beller GA, et al. Increased lung uptake of thallium-201 during exercise myocardial imaging: clinical, hemodynamic and angiographic implications in patients with coronary artery disease. J Am Coll Cardiol. 1980;46:189-196.
-
(1980)
J Am Coll Cardiol
, vol.46
, pp. 189-196
-
-
Boucher, C.A.1
Zir, L.M.2
Beller, G.A.3
-
21
-
-
0019195397
-
Influence of coronary artery disease on pulmonaryuptake of thallium-201
-
Bingham JH, McKusick KA, Strauss HW, et al. Influence of coronary artery disease on pulmonaryuptake of thallium-201. Am J Cardiol. 1980;46:821-826.
-
(1980)
Am J Cardiol
, vol.46
, pp. 821-826
-
-
Bingham, J.H.1
McKusick, K.A.2
Strauss, H.W.3
-
22
-
-
0020593735
-
Analysis of the degree of pulmonary thallium washout after exercise in patients with coronary artery disease
-
Levy R, Rosanski A, Berman DS, et al. Analysis of the degree of pulmonary thallium washout after exercise in patients with coronary artery disease. J Am Coll Cardiol. 1983;2:719-728.
-
(1983)
J Am Coll Cardiol
, vol.2
, pp. 719-728
-
-
Levy, R.1
Rosanski, A.2
Berman, D.S.3
-
23
-
-
0023650427
-
Prognostic importance of thallium uptake by the lungs during exercise in coronary artery disease
-
Gill JB, Ruddy TD, Newell JB, et al. Prognostic importance of thallium uptake by the lungs during exercise in coronary artery disease. N Engl J Med. 1987;317:1486-1489.
-
(1987)
N Engl J Med
, vol.317
, pp. 1486-1489
-
-
Gill, J.B.1
Ruddy, T.D.2
Newell, J.B.3
-
24
-
-
0025201249
-
Prevalence and correlates of increased lung/heart ratio of thallium 201 during dipyridamole stress imaging for suspected coronary artery disease
-
Villanueva FS, Kaul S, Smith WH, et al. Prevalence and correlates of increased lung/heart ratio of thallium 201 during dipyridamole stress imaging for suspected coronary artery disease. Am J Cardiol. 1990;66:1324-1328.
-
(1990)
Am J Cardiol
, vol.66
, pp. 1324-1328
-
-
Villanueva, F.S.1
Kaul, S.2
Smith, W.H.3
-
25
-
-
0008214292
-
Myocardial thallium-201 imaging for detection of myocardial viability
-
Zaret BL, Beller GA, eds. St. Louis, MO: Mosby
-
Beller GA. Myocardial thallium-201 imaging for detection of myocardial viability. In: Zaret BL, Beller GA, eds. Nuclear Cardiology: State of the Art and Future Directions. St. Louis, MO: Mosby; 1993:227-235.
-
(1993)
Nuclear Cardiology: State of the Art and Future Directions
, pp. 227-235
-
-
Beller, G.A.1
-
26
-
-
0001628065
-
Myocardial viability in chronic coronary artery disease: Perfusion, metabolism, and contractile reserve
-
Gerson MC, ed. New York, NY: McGraw-Hill
-
Dilsizian V, Arrighi JA. Myocardial viability in chronic coronary artery disease: perfusion, metabolism, and contractile reserve. In: Gerson MC, ed. Cardiac Nuclear Medicine. New York, NY: McGraw-Hill; 1997:143-191.
-
(1997)
Cardiac Nuclear Medicine
, pp. 143-191
-
-
Dilsizian, V.1
Arrighi, J.A.2
-
27
-
-
0002298141
-
Count density and filter requirements for accurate LVEF measurements from gated TI-201 SPECT: A gated MCAT study
-
Case JA, Cullom SJ, Bateman TM, O'Keefe JH, Williams ME. Count density and filter requirements for accurate LVEF measurements from gated TI-201 SPECT: a gated MCAT study [abstract]. J Nucl Med. 1997;5:27P.
-
(1997)
J Nucl Med
, vol.5
-
-
Case, J.A.1
Cullom, S.J.2
Bateman, T.M.3
O'Keefe, J.H.4
Williams, M.E.5
-
28
-
-
0024384058
-
Quantification of three-dimentional left ventricular segmental wall motion and volumes from gated tomographic radionuclide ventriculograms
-
Faber TL, Stokely EM, Templeton GH, Akers MS, Parkey RW, Corbett JR. Quantification of three-dimentional left ventricular segmental wall motion and volumes from gated tomographic radionuclide ventriculograms. J Nucl Med. 1989;30:638-649.
-
(1989)
J Nucl Med
, vol.30
, pp. 638-649
-
-
Faber, T.L.1
Stokely, E.M.2
Templeton, G.H.3
Akers, M.S.4
Parkey, R.W.5
Corbett, J.R.6
-
30
-
-
0028222783
-
Gated technetium-99m sestamibi for simultaneous assessment of stress myocardial perfusion, postexercice regional ventricular function and myocardial viability. Correlation with echocardiography and rest thallium-201 scintigraphy
-
Chua T, Kiat H, Germano G, et al. Gated technetium-99m sestamibi for simultaneous assessment of stress myocardial perfusion, postexercice regional ventricular function and myocardial viability. Correlation with echocardiography and rest thallium-201 scintigraphy. J Am Coll Cardiol. 1994;23:1107-1114.
-
(1994)
J Am Coll Cardiol
, vol.23
, pp. 1107-1114
-
-
Chua, T.1
Kiat, H.2
Germano, G.3
-
31
-
-
0028998051
-
Automatic reorientation of three-dimensional transaxial myocardial perfusion SPECT images
-
Germano G, Kavanagh PB, Su HT, et al. Automatic reorientation of three-dimensional transaxial myocardial perfusion SPECT images. J Nucl Med. 1995;36:1107-1114.
-
(1995)
J Nucl Med
, vol.36
, pp. 1107-1114
-
-
Germano, G.1
Kavanagh, P.B.2
Su, H.T.3
-
33
-
-
10244255177
-
Is the addition of ECG gating to technetium-99m sestamibi SPET of value in the assessment of myocardial viability. An evaluation based on two-dimensional echocardiography following revascularization
-
Gonzalez P, Massardo T, Munoz A, et al. Is the addition of ECG gating to technetium-99m sestamibi SPET of value in the assessment of myocardial viability. An evaluation based on two-dimensional echocardiography following revascularization. Eur J Nucl Med. 1996;23:1315-1322.
-
(1996)
Eur J Nucl Med
, vol.23
, pp. 1315-1322
-
-
Gonzalez, P.1
Massardo, T.2
Munoz, A.3
-
34
-
-
0029993428
-
Comparison of technetium-99m sestamibi-gated tomographic perfusion imaging with echocardiography and electrocardiography for determination of left ventricular mass
-
Williams KA, Roberto ML, Reha RC, Taillon LA. Comparison of technetium-99m sestamibi-gated tomographic perfusion imaging with echocardiography and electrocardiography for determination of left ventricular mass. Am J Cardiol. 1996;77:750-755.
-
(1996)
Am J Cardiol
, vol.77
, pp. 750-755
-
-
Williams, K.A.1
Roberto, M.L.2
Reha, R.C.3
Taillon, L.A.4
-
35
-
-
0030980475
-
Combined analysis of resting regional wall thickening and stress perfusion with electrocardiographic-gated technetium 99m-labeled sestamibi single photon emission computed tomography: Prediction at stress defect reversibility
-
Snapper HJ, Shea NL, Konstam MA, Oates E, Udelson JE. Combined analysis of resting regional wall thickening and stress perfusion with electrocardiographic-gated technetium 99m-labeled sestamibi single photon emission computed tomography: prediction at stress defect reversibility. J Nucl Cardiol. 1997;4:3-10.
-
(1997)
J Nucl Cardiol
, vol.4
, pp. 3-10
-
-
Snapper, H.J.1
Shea, N.L.2
Konstam, M.A.3
Oates, E.4
Udelson, J.E.5
-
36
-
-
0031032541
-
Comparative diagnostic accuracy of TI-201 and Tc-99m sestamibi SPECT imaging (perfusion and ECG-gated SPECT) in detecting coronary artery disease in women
-
Taillefer R, DePuey EG, Udelson JE, Beller GA, Latour Y, Reeves F. Comparative diagnostic accuracy of TI-201 and Tc-99m sestamibi SPECT imaging (perfusion and ECG-gated SPECT) in detecting coronary artery disease in women. J Am Coll Cardiol. 1997;29:69-77.
-
(1997)
J Am Coll Cardiol
, vol.29
, pp. 69-77
-
-
Taillefer, R.1
DePuey, E.G.2
Udelson, J.E.3
Beller, G.A.4
Latour, Y.5
Reeves, F.6
-
37
-
-
0002887315
-
Left ventricular ejection fraction (LVEF) assessment by myocardial gated SPECT: Comparison of two methods
-
Wartski M, Gremillet E. Left ventricular ejection fraction (LVEF) assessment by myocardial gated SPECT: comparison of two methods [abstract]. J Nucl Med. 1997;5:27P.
-
(1997)
J Nucl Med
, vol.5
-
-
Wartski, M.1
Gremillet, E.2
-
38
-
-
0029069659
-
Using gated technetiurn-99m-sestamibi SPECT to characterise fixed myocardial defect as infarct or artifact
-
Depuey EG, Rozanski A. Using gated technetiurn-99m-sestamibi SPECT to characterise fixed myocardial defect as infarct or artifact. J Nucl Med. 1995;36: 952-955.
-
(1995)
J Nucl Med
, vol.36
, pp. 952-955
-
-
Depuey, E.G.1
Rozanski, A.2
-
39
-
-
0029805381
-
Effect of the number of projections collected on quantitative perfusion and left ventricular ejection fraction measurements from gated myocardial perfusion single-photon emission computed tomographic images
-
Germano G, Kavanagh PB, Berman DS. Effect of the number of projections collected on quantitative perfusion and left ventricular ejection fraction measurements from gated myocardial perfusion single-photon emission computed tomographic images. J Nucl Cardiol. 1996;3:395-402.
-
(1996)
J Nucl Cardiol
, vol.3
, pp. 395-402
-
-
Germano, G.1
Kavanagh, P.B.2
Berman, D.S.3
|