메뉴 건너뛰기




Volumn 68, Issue 2, 1999, Pages 209-216

Clinical value of parameters derived by the application of the proximal isovelocity surface area method in the assessment of mitral regurgitation

Author keywords

Cardiac catheterization; Color Doppler echocardiography; Mitral regurgitation; Proximal isovelocity surface area

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; DOPPLER ECHOCARDIOGRAPHY; FEMALE; HEART CATHETERIZATION; HEART STROKE VOLUME; HUMAN; MALE; MITRAL VALVE REGURGITATION; PRIORITY JOURNAL; SURFACE PROPERTY; VELOCITY;

EID: 0344019487     PISSN: 01675273     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0167-5273(98)00355-6     Document Type: Article
Times cited : (11)

References (40)
  • 1
    • 0014272759 scopus 로고
    • The angiographic assessment of mitral incompetence
    • Nagle R.E., Walker D., Grainger R.G. The angiographic assessment of mitral incompetence. Clin Radiol. 19:1968;154-164.
    • (1968) Clin Radiol , vol.19 , pp. 154-164
    • Nagle, R.E.1    Walker, D.2    Grainger, R.G.3
  • 2
    • 0021242793 scopus 로고
    • Limitations of qualitative angiographic grading in aortic or mitral regurgitation
    • Croft C.H., Lipscomb K., Mathis K. Limitations of qualitative angiographic grading in aortic or mitral regurgitation. Am J Cardiol. 53:1984;1593-1598.
    • (1984) Am J Cardiol , vol.53 , pp. 1593-1598
    • Croft, C.H.1    Lipscomb, K.2    Mathis, K.3
  • 3
    • 0000994360 scopus 로고
    • Profiles in valvular heart disease
    • In: Grossman W, Baim DS (Eds.), Philadelphia: Lea and Febiger
    • Grossman W. Profiles in valvular heart disease. In: Grossman W, Baim DS (Eds.), Cardiac catheterization, angiography and intervention, 4th ed., Philadelphia: Lea and Febiger, 1991, pp. 563-568.
    • (1991) Cardiac Catheterization, Angiography and Intervention, 4th Ed. , pp. 563-568
    • Grossman, W.1
  • 4
    • 0022592983 scopus 로고
    • Semiquantitative grading of severity of mitral regurgitation by real-time two-dimensional Doppler flow imaging technique
    • Miyatake K., Izumi S., Okamoto M.et al. Semiquantitative grading of severity of mitral regurgitation by real-time two-dimensional Doppler flow imaging technique. J Am Coll Cardiol. 7:1986;82-88.
    • (1986) J Am Coll Cardiol , vol.7 , pp. 82-88
    • Miyatake, K.1    Izumi, S.2    Okamoto, M.3
  • 5
    • 0023142657 scopus 로고
    • Color Doppler assessment of mitral regurgitation with orthogonal planes
    • Helmcke F., Nanda N.C., Hsiun M.C.et al. Color Doppler assessment of mitral regurgitation with orthogonal planes. Circulation. 75:1987;175-183.
    • (1987) Circulation , vol.75 , pp. 175-183
    • Helmcke, F.1    Nanda, N.C.2    Hsiun, M.C.3
  • 6
    • 0024566051 scopus 로고
    • Quantitative assessment of mitral regurgitation by Doppler color flow imaging: Angiographic and hemodynamic correlations
    • Spain M.G., Smith M.D., Grayburn P.A., Harlamert E.A., DeMaria A.N. Quantitative assessment of mitral regurgitation by Doppler color flow imaging: Angiographic and hemodynamic correlations. J Am Coll Cardiol. 13:1989;585-590.
    • (1989) J Am Coll Cardiol , vol.13 , pp. 585-590
    • Spain, M.G.1    Smith, M.D.2    Grayburn, P.A.3    Harlamert, E.A.4    Demaria, A.N.5
  • 7
    • 0026682773 scopus 로고
    • Variability in the quantitation of mitral regurgitation by Doppler color flow mapping: Comparison of transthoracic and transesophageal studies
    • Castello R., Lenzen P., Aguirre F., Labovitz A. Variability in the quantitation of mitral regurgitation by Doppler color flow mapping: Comparison of transthoracic and transesophageal studies. J Am Coll Cardiol. 20:1992;433-438.
    • (1992) J Am Coll Cardiol , vol.20 , pp. 433-438
    • Castello, R.1    Lenzen, P.2    Aguirre, F.3    Labovitz, A.4
  • 8
    • 0024327348 scopus 로고
    • A new method for noninvasive quantification of valvular regurgitation based on conservation of momentum: An in vitro validation
    • Cape E.G., Yoganathan A.P., Levine R.A. A new method for noninvasive quantification of valvular regurgitation based on conservation of momentum: An in vitro validation. Circulation. 79:1989;1343-1353.
    • (1989) Circulation , vol.79 , pp. 1343-1353
    • Cape, E.G.1    Yoganathan, A.P.2    Levine, R.A.3
  • 10
    • 0030018459 scopus 로고    scopus 로고
    • Quantification of mitral and tricuspid regurgitation using jet centerline velocities: An in vitro study of jets in an ambient counterflow
    • Grimes R.Y., Hopmeyer J., Cape E.G., Yoganathan A.P., Levine R.A. Quantification of mitral and tricuspid regurgitation using jet centerline velocities: An in vitro study of jets in an ambient counterflow. Echocardiography. 13:1996;357-371.
    • (1996) Echocardiography , vol.13 , pp. 357-371
    • Grimes, R.Y.1    Hopmeyer, J.2    Cape, E.G.3    Yoganathan, A.P.4    Levine, R.A.5
  • 11
    • 0344698533 scopus 로고
    • Quantitative assessment of mitral regurgitation by color Doppler analysis of flow convergence region: Usefulness of continuity equation
    • Rome
    • Bargiggia GS, Bertucci C, Raisaro A, et al. Quantitative assessment of mitral regurgitation by color Doppler analysis of flow convergence region: Usefulness of continuity equation, Proc. 6th Intl. Congr. on Cardiac Doppler, Rome, 1988:140.
    • (1988) Proc. 6th Intl. Congr. on Cardiac Doppler , pp. 140
    • Bargiggia, G.S.1    Bertucci, C.2    Raisaro, A.3
  • 12
    • 0026069172 scopus 로고
    • A new method for quantification of regurgitant flow rate using color Doppler flow imaging of the flow convergence region proximal to a discrete orifice: An in vitro study
    • Recusani F., Bargiggia G.S., Yoganathan A.P.et al. A new method for quantification of regurgitant flow rate using color Doppler flow imaging of the flow convergence region proximal to a discrete orifice: An in vitro study. Circulation. 83:1991;594-604.
    • (1991) Circulation , vol.83 , pp. 594-604
    • Recusani, F.1    Bargiggia, G.S.2    Yoganathan, A.P.3
  • 13
    • 0025939920 scopus 로고
    • A new method for quantitation of mitral regurgitation based on color flow Doppler imaging of flow convergence proximal to regurgitant orifice
    • Bargiggia G., Tronconi L., Shan D.J.et al. A new method for quantitation of mitral regurgitation based on color flow Doppler imaging of flow convergence proximal to regurgitant orifice. Circulation. 84:1991;1481-1489.
    • (1991) Circulation , vol.84 , pp. 1481-1489
    • Bargiggia, G.1    Tronconi, L.2    Shan, D.J.3
  • 14
    • 0026196497 scopus 로고
    • Doppler color flow mapping of the proximal isovelocity surface area: A new method for measuring volume flow rate across a narrowed orifice
    • Utsunomiya T., Ogawa T., Tang H.A.et al. Doppler color flow mapping of the proximal isovelocity surface area: A new method for measuring volume flow rate across a narrowed orifice. J Am Soc Echocardiogr. 4:1991;338-348.
    • (1991) J Am Soc Echocardiogr , vol.4 , pp. 338-348
    • Utsunomiya, T.1    Ogawa, T.2    Tang, H.A.3
  • 15
    • 0026463187 scopus 로고
    • Quantification of mitral regurgitation with the proximal flow convergence method: A clinical study
    • Rivera J.M., Vandervoort P.M., Thoreau D.H., Levine R.A., Weyman A.E., Thomas J.D. Quantification of mitral regurgitation with the proximal flow convergence method: A clinical study. Am Heart J. 124:1992;1289-1296.
    • (1992) Am Heart J , vol.124 , pp. 1289-1296
    • Rivera, J.M.1    Vandervoort, P.M.2    Thoreau, D.H.3    Levine, R.A.4    Weyman, A.E.5    Thomas, J.D.6
  • 16
    • 0027234089 scopus 로고
    • Application of color Doppler flow mapping to calculate effective regurgitant orifice area. An in vitro study and initial clinical observations
    • Vandervoort P.M., Rivera J.M., Mele D.et al. Application of color Doppler flow mapping to calculate effective regurgitant orifice area. An in vitro study and initial clinical observations. Circulation. 88:1993;1150-1156.
    • (1993) Circulation , vol.88 , pp. 1150-1156
    • Vandervoort, P.M.1    Rivera, J.M.2    Mele, D.3
  • 17
    • 0020665265 scopus 로고
    • The mitral valve orifice method for noninvasive two-dimensional echo Doppler determination of cardiac output
    • Fisher D.C., Sahn D.J., Friedman M.J.et al. The mitral valve orifice method for noninvasive two-dimensional echo Doppler determination of cardiac output. Circulation. 67:1983;872-877.
    • (1983) Circulation , vol.67 , pp. 872-877
    • Fisher, D.C.1    Sahn, D.J.2    Friedman, M.J.3
  • 18
    • 49749212248 scopus 로고
    • Left retrograde cardioangiography in acquired cardiac disease
    • Sellers R.D., Levy M.J., Amplatz L., Lillehei C.W. Left retrograde cardioangiography in acquired cardiac disease. Am J Cardiol. 14:1964;432-442.
    • (1964) Am J Cardiol , vol.14 , pp. 432-442
    • Sellers, R.D.1    Levy, M.J.2    Amplatz, L.3    Lillehei, C.W.4
  • 19
    • 0027254652 scopus 로고
    • Validation of the proximal flow convergence method. Calculation of orifice area in patients with mitral stenosis
    • Rodriguez L., Thomas J.D., Monterroso V.et al. Validation of the proximal flow convergence method. Calculation of orifice area in patients with mitral stenosis. Circulation. 88:1993;1157-1165.
    • (1993) Circulation , vol.88 , pp. 1157-1165
    • Rodriguez, L.1    Thomas, J.D.2    Monterroso, V.3
  • 20
    • 0344266811 scopus 로고
    • Calculation of mitral valve area in patients with mitral stenosis by color Doppler Echocardiography. Method of the proximal isovelocity surface area
    • Salvador A., Miró V., Mora V., Almenar L., Sotillo J., Sancho-Tello M.J. Calculation of mitral valve area in patients with mitral stenosis by color Doppler Echocardiography. Method of the proximal isovelocity surface area. Eur Heart J. 12(Suppl):1991;233.
    • (1991) Eur Heart J , vol.12 , Issue.SUPPL , pp. 233
    • Salvador, A.1    Miró, V.2    Mora, V.3    Almenar, L.4    Sotillo, J.5    Sancho-Tello, M.J.6
  • 21
    • 0027160502 scopus 로고
    • Quantification of left-to-right shunting and defect size after balloon mitral commissurotomy using biplane transesophageal echocardiography, color flow Doppler mapping, and the principle of proximal flow convergence
    • Rittoo D., Sutherland G.R., Shaw T.R. Quantification of left-to-right shunting and defect size after balloon mitral commissurotomy using biplane transesophageal echocardiography, color flow Doppler mapping, and the principle of proximal flow convergence. Circulation. 87:1993;1591-1603.
    • (1993) Circulation , vol.87 , pp. 1591-1603
    • Rittoo, D.1    Sutherland, G.R.2    Shaw, T.R.3
  • 22
    • 24444458358 scopus 로고
    • A new method for noninvasive estimation of ventricular septal defect (VSD) shunt flow by color Doppler: Imaging of the laminar flow convergence region on the left septal surface
    • Moises V.A., Hornberger L., Maciel B., Murillo A., Sahn D.J. A new method for noninvasive estimation of ventricular septal defect (VSD) shunt flow by color Doppler: Imaging of the laminar flow convergence region on the left septal surface. J Am Coll Cardiol. 13:1989;205A.
    • (1989) J Am Coll Cardiol , vol.13
    • Moises, V.A.1    Hornberger, L.2    Maciel, B.3    Murillo, A.4    Sahn, D.J.5
  • 23
    • 0025354282 scopus 로고
    • Mitral regurgitation: Parameters that affect the correlation between Doppler echocardiography and contrast ventriculography
    • Gal R.A., Shalev Y., Schmidt D.H. Mitral regurgitation: Parameters that affect the correlation between Doppler echocardiography and contrast ventriculography. Intl J Cardiol. 28:1990;87-93.
    • (1990) Intl J Cardiol , vol.28 , pp. 87-93
    • Gal, R.A.1    Shalev, Y.2    Schmidt, D.H.3
  • 24
    • 0025881952 scopus 로고
    • Adjacent solid boundaries alter the size of regurgitant jets on Doppler color flow maps
    • Cape E.G., Yoganathan A.P., Weyman A.E., Levine R.A. Adjacent solid boundaries alter the size of regurgitant jets on Doppler color flow maps. J Am Coll Cardiol. 17:1991;1094-1102.
    • (1991) J Am Coll Cardiol , vol.17 , pp. 1094-1102
    • Cape, E.G.1    Yoganathan, A.P.2    Weyman, A.E.3    Levine, R.A.4
  • 25
    • 0025737199 scopus 로고
    • Impact of impinging wall jet on color Doppler quantification of mitral regurgitation
    • Chen C., Thomas J.D., Anconina J.et al. Impact of impinging wall jet on color Doppler quantification of mitral regurgitation. Circulation. 84:1991;712-720.
    • (1991) Circulation , vol.84 , pp. 712-720
    • Chen, C.1    Thomas, J.D.2    Anconina, J.3
  • 26
    • 0026078437 scopus 로고
    • Effects of pressure and volume of the receiving chamber on the spatial distribution of regurgitant jets as imaged by color Doppler flow mapping
    • Maciel B.C., Moises V.A., Shandas R. Effects of pressure and volume of the receiving chamber on the spatial distribution of regurgitant jets as imaged by color Doppler flow mapping. Circulation. 83:1991;605-613.
    • (1991) Circulation , vol.83 , pp. 605-613
    • Maciel, B.C.1    Moises, V.A.2    Shandas, R.3
  • 27
    • 0029036763 scopus 로고
    • Atrial inflow can alter color Doppler regurgitant jet area: In vitro studies
    • Grimes R.Y., Nyarko S.J., Pulido G.A.et al. Atrial inflow can alter color Doppler regurgitant jet area: In vitro studies. Ultrasound Med Biol. 21:1995;459-469.
    • (1995) Ultrasound Med Biol , vol.21 , pp. 459-469
    • Grimes, R.Y.1    Nyarko, S.J.2    Pulido, G.A.3
  • 28
    • 0024363326 scopus 로고
    • Two-dimensional color Doppler estimation of the severity of atrioventricular valve regurgitation: Important effects of instrument gain setting, pulse repetition frequency, and carrier frequency
    • Stevenson J.G. Two-dimensional color Doppler estimation of the severity of atrioventricular valve regurgitation: Important effects of instrument gain setting, pulse repetition frequency, and carrier frequency. J Am Soc EchoCardiogr. 2:1989;1-10.
    • (1989) J Am Soc EchoCardiogr , vol.2 , pp. 1-10
    • Stevenson, J.G.1
  • 29
    • 0023698346 scopus 로고
    • Instrumentation and physical factors related to visualization of stenotic and regurgitant jets by Doppler color flow mapping
    • Shan D.J. Instrumentation and physical factors related to visualization of stenotic and regurgitant jets by Doppler color flow mapping. J Am Coll Cardiol. 12:1988;1354-1365.
    • (1988) J Am Coll Cardiol , vol.12 , pp. 1354-1365
    • Shan, D.J.1
  • 30
    • 0025244342 scopus 로고
    • Pitfalls in the display of Doppler color jet areas: Combined variability due to Doppler angle, frame rate, and scanning direction
    • Utsunomiya T., Ogawa T., King S.W.et al. Pitfalls in the display of Doppler color jet areas: Combined variability due to Doppler angle, frame rate, and scanning direction. Echocardiography. 7:1990;739-745.
    • (1990) Echocardiography , vol.7 , pp. 739-745
    • Utsunomiya, T.1    Ogawa, T.2    King, S.W.3
  • 31
    • 0025728517 scopus 로고
    • Doppler color flow proximal isovelocity surface area method for estimating volume flow rate: Effects of orifice shape and machine factors
    • Utsunomiya T., Ogawa T., Doshi R.et al. Doppler color flow proximal isovelocity surface area method for estimating volume flow rate: Effects of orifice shape and machine factors. J Am Coll Cardiol. 17:1991;1103-1111.
    • (1991) J Am Coll Cardiol , vol.17 , pp. 1103-1111
    • Utsunomiya, T.1    Ogawa, T.2    Doshi, R.3
  • 32
    • 0027516069 scopus 로고
    • Non-invasive estimation of regurgitant flow rate and volume in patients with mitral regurgitation by Doppler color mapping of accelerating flow field
    • Chen C., Koschyk D., Brockhoff C.et al. Non-invasive estimation of regurgitant flow rate and volume in patients with mitral regurgitation by Doppler color mapping of accelerating flow field. J Am Coll Cardiol. 21:1993;374-383.
    • (1993) J Am Coll Cardiol , vol.21 , pp. 374-383
    • Chen, C.1    Koschyk, D.2    Brockhoff, C.3
  • 33
    • 0027157399 scopus 로고
    • Calculation of volume flow rate by the proximal isovelocity surface area method: Simplified approach using color Doppler zero baseline shift
    • Utsunomiya T., Doshi R., Patel D.et al. Calculation of volume flow rate by the proximal isovelocity surface area method: Simplified approach using color Doppler zero baseline shift. J Am Coll Cardiol. 22:1993;277-282.
    • (1993) J Am Coll Cardiol , vol.22 , pp. 277-282
    • Utsunomiya, T.1    Doshi, R.2    Patel, D.3
  • 35
    • 0345560737 scopus 로고
    • The flow convergence region proximal to a regurgitant orifice has a non-hemispherical velocity field
    • Barclay SA, Changsheng X, Loyd D, Andersson G, Ask P, Wranne B. The flow convergence region proximal to a regurgitant orifice has a non-hemispherical velocity field. Circulation 1991;84:11-105.
    • (1991) Circulation , vol.84 , pp. 11-105
    • Barclay, S.A.1    Changsheng, X.2    Loyd, D.3    Andersson, G.4    Ask, P.5    Wranne, B.6
  • 36
    • 0026537396 scopus 로고
    • Impact of finite orifice size on proximal flow convergence. Implications for Doppler quantification of valvular regurgitation
    • Rodriguez L., Anconina J., Flachskampf F., Weyman A.E., Levine R.A., Thomas J.D. Impact of finite orifice size on proximal flow convergence. Implications for Doppler quantification of valvular regurgitation. Cir Res. 70:1992;923-930.
    • (1992) Cir Res , vol.70 , pp. 923-930
    • Rodriguez, L.1    Anconina, J.2    Flachskampf, F.3    Weyman, A.E.4    Levine, R.A.5    Thomas, J.D.6
  • 37
    • 0027443772 scopus 로고
    • Cardiac motion can alter proximal isovelocity surface area calculations of regurgitant flow
    • Cape E.G., Kim Y.H., Heinrich R.S.et al. Cardiac motion can alter proximal isovelocity surface area calculations of regurgitant flow. J Am Coll Cardiol. 22:1993;1730-1737.
    • (1993) J Am Coll Cardiol , vol.22 , pp. 1730-1737
    • Cape, E.G.1    Kim, Y.H.2    Heinrich, R.S.3
  • 38
    • 0029715388 scopus 로고    scopus 로고
    • The effect of aortic outflow on the quantification of mitral regurgitation using the flow convergence method
    • Hopmeyer J., Fontaine A., Yang S.et al. The effect of aortic outflow on the quantification of mitral regurgitation using the flow convergence method. J Am Soc Echocardiogr. 9:1996;44-47.
    • (1996) J Am Soc Echocardiogr , vol.9 , pp. 44-47
    • Hopmeyer, J.1    Fontaine, A.2    Yang, S.3
  • 39
    • 0027325706 scopus 로고
    • Automated flow rate calculations based on digital analysis of flow convergence proximal to regurgitant orifices
    • Vandervoort P.M., Thoreau D.H., Rivera J.M.et al. Automated flow rate calculations based on digital analysis of flow convergence proximal to regurgitant orifices. J Am Coll Cardiol. 22:1993;535-541.
    • (1993) J Am Coll Cardiol , vol.22 , pp. 535-541
    • Vandervoort, P.M.1    Thoreau, D.H.2    Rivera, J.M.3
  • 40
    • 0029362288 scopus 로고
    • Three-dimensional surface geometry correction is required for calculating flow by the proximal isovelocity surface area technique
    • Cape E.G., Thomas J.D., Weyman A.E.et al. Three-dimensional surface geometry correction is required for calculating flow by the proximal isovelocity surface area technique. J Am Soc Echocardiogr. 8:1995;585-594.
    • (1995) J Am Soc Echocardiogr , vol.8 , pp. 585-594
    • Cape, E.G.1    Thomas, J.D.2    Weyman, A.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.