메뉴 건너뛰기




Volumn 28, Issue 6, 2003, Pages 904-909

Management of the Scaphoid during Four-Corner Fusion - A Cadaveric Study

Author keywords

Midcarpal fusion; Partial wrist arthrodesis

Indexed keywords

ARM; ARTHRODESIS; ARTICLE; CADAVER; CONTROLLED STUDY; EXPERIMENTAL MODEL; HAND MOVEMENT; HAND SURGERY; HUMAN; HUMAN TISSUE; JOINT LIMITATION; PRIORITY JOURNAL; SCAPHOID BONE; SIMULATION; WRIST;

EID: 0344010069     PISSN: 03635023     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0363-5023(03)00372-1     Document Type: Article
Times cited : (24)

References (14)
  • 2
    • 0035146864 scopus 로고    scopus 로고
    • Degenerative arthritis of the wrist: Proximal row carpectomy versus scaphoid excision and four-corner arthrodesis
    • Cohen MS, Kozin SH. Degenerative arthritis of the wrist: proximal row carpectomy versus scaphoid excision and four-corner arthrodesis. J Hand Surg 2001;26A:94-104.
    • (2001) J Hand Surg , vol.26 A , pp. 94-104
    • Cohen, M.S.1    Kozin, S.H.2
  • 3
    • 0027976969 scopus 로고
    • Scapholunate advanced collapse wrist: Proximal row carpectomy or limited wrist arthrodesis with scaphoid excision?
    • Tomaino MM, Miller RJ, Cole I, Burton RI. Scapholunate advanced collapse wrist: proximal row carpectomy or limited wrist arthrodesis with scaphoid excision? J Hand Surg 1994;19A:134-142.
    • (1994) J Hand Surg , vol.19 A , pp. 134-142
    • Tomaino, M.M.1    Miller, R.J.2    Cole, I.3    Burton, R.I.4
  • 4
    • 0029147566 scopus 로고
    • The effect of intercarpal joint motion on wrist motion: Are there key joints? An in vitro study
    • Seradge H, Owens W, Seradge E. The effect of intercarpal joint motion on wrist motion: are there key joints? An in vitro study. Orthopedics 1995;18:727-732.
    • (1995) Orthopedics , vol.18 , pp. 727-732
    • Seradge, H.1    Owens, W.2    Seradge, E.3
  • 5
    • 0023918931 scopus 로고
    • An in vitro analysis of wrist motion: The effect of limited intercarpal arthrodesis and the contributions of the radiocarpal and midcarpal joints
    • Gellman H, Kauffman D, Lenihan M, Botte MJ, Sarmiento A. An in vitro analysis of wrist motion: the effect of limited intercarpal arthrodesis and the contributions of the radiocarpal and midcarpal joints. J Hand Surg 1988;13A:390-395.
    • (1988) J Hand Surg , vol.13 A , pp. 390-395
    • Gellman, H.1    Kauffman, D.2    Lenihan, M.3    Botte, M.J.4    Sarmiento, A.5
  • 7
    • 0021227298 scopus 로고
    • Subtotal arthrodeses of the wrist joint
    • Taleisnik J. Subtotal arthrodeses of the wrist joint. Clin Orthop 1984;187:81-88.
    • (1984) Clin Orthop , vol.187 , pp. 81-88
    • Taleisnik, J.1
  • 9
    • 0028883855 scopus 로고
    • Motion-preserving procedures in the treatment of scapholunate advanced collapse wrist: Proximal row carpectomy versus four-corner arthrodesis
    • Wyrick JD, Stern PJ, Kiefhaber TR. Motion-preserving procedures in the treatment of scapholunate advanced collapse wrist: proximal row carpectomy versus four-corner arthrodesis. J Hand Surg 1995;20A:965-970.
    • (1995) J Hand Surg , vol.20 A , pp. 965-970
    • Wyrick, J.D.1    Stern, P.J.2    Kiefhaber, T.R.3
  • 11
    • 0029982029 scopus 로고    scopus 로고
    • Midcarpal arthrodesis
    • Siegel JM, Ruby LK. Midcarpal arthrodesis. J Hand Surg 1996;21A:179-182.
    • (1996) J Hand Surg , vol.21 A , pp. 179-182
    • Siegel, J.M.1    Ruby, L.K.2
  • 12
    • 0025281460 scopus 로고
    • Evaluation of the biomechanical efficacy of limited intercarpal fusions for the treatment of scapho-lunate dissociation
    • Viegas SF, Patterson RM, Peterson PD, Pogue DJ, Jenkins DK, Sweo TD, et al. Evaluation of the biomechanical efficacy of limited intercarpal fusions for the treatment of scapho-lunate dissociation. J Hand Surg 1990;15A:120-128.
    • (1990) J Hand Surg , vol.15 A , pp. 120-128
    • Viegas, S.F.1    Patterson, R.M.2    Peterson, P.D.3    Pogue, D.J.4    Jenkins, D.K.5    Sweo, T.D.6
  • 13
    • 0023521336 scopus 로고
    • Load transfer characteristics of the wrist. Part II. Perilunate instability
    • Viegas SF, Tencer AF, Cantrell J, Chang M, Clegg P, Hicks C, et al. Load transfer characteristics of the wrist. Part II. Perilunate instability. J Hand Surg 1987;12A:978-985.
    • (1987) J Hand Surg , vol.12 A , pp. 978-985
    • Viegas, S.F.1    Tencer, A.F.2    Cantrell, J.3    Chang, M.4    Clegg, P.5    Hicks, C.6
  • 14
    • 0030624879 scopus 로고    scopus 로고
    • The effects of time and light exposure on contact and pressure measurements using Fuji prescale film
    • Patterson R, Pogue D, Viegas S. The effects of time and light exposure on contact and pressure measurements using Fuji prescale film. Iowa Orthop J 1997;17:64-69.
    • (1997) Iowa Orthop J , vol.17 , pp. 64-69
    • Patterson, R.1    Pogue, D.2    Viegas, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.