메뉴 건너뛰기




Volumn 99, Issue 1, 2000, Pages 41-50

A novel enzyme immunoassay for plasma thrombospondin: Comparison with beta-thromboglobulin as platelet activation marker in vitro and in vivo

Author keywords

Beta thromboglobulin; Biocompatibility; Cardiopulmonary bypass; Enzyme immunoassay; Heparin; Platelets; Thrombospondin

Indexed keywords

ADENOSINE; BETA THROMBOGLOBULIN; DIPYRIDAMOLE; HEPARIN; THEOPHYLLINE; THROMBOSPONDIN;

EID: 0343603522     PISSN: 00493848     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0049-3848(00)00226-7     Document Type: Article
Times cited : (36)

References (31)
  • 1
    • 0022495145 scopus 로고
    • The structural and functional properties of thrombospondin
    • Lawler J. The structural and functional properties of thrombospondin. Blood. 67:1986;1197-1209.
    • (1986) Blood , vol.67 , pp. 1197-1209
    • Lawler, J.1
  • 2
    • 0025343641 scopus 로고
    • Physiology of thrombospondin
    • Mosher D.F. Physiology of thrombospondin. Annu Rev Med. 41:1990;85-97.
    • (1990) Annu Rev Med , vol.41 , pp. 85-97
    • Mosher, D.F.1
  • 4
    • 0027319916 scopus 로고
    • The functions of thrombospondin and its involvement in physiology and pathophysiology
    • Lahav J. The functions of thrombospondin and its involvement in physiology and pathophysiology. Biochim Biophys Acta. 1182:1993;1-14.
    • (1993) Biochim Biophys Acta , vol.1182 , pp. 1-14
    • Lahav, J.1
  • 6
  • 9
    • 0023624307 scopus 로고
    • Plasma thrombospondin as an indicator of intravascular platelet activation in patients with vasculitis
    • McCrohan M.B., Huang S.W., Sleasman J.W., Klein P.A., Kao K.J. Plasma thrombospondin as an indicator of intravascular platelet activation in patients with vasculitis. Thromb Haemost. 58:1987;850-852.
    • (1987) Thromb Haemost , vol.58 , pp. 850-852
    • McCrohan, M.B.1    Huang, S.W.2    Sleasman, J.W.3    Klein, P.A.4    Kao, K.J.5
  • 10
    • 0022390843 scopus 로고
    • Comparative evaluation of plasma thrombospondin beta- thromboglobulin and platelet factor 4 in acute myocardial infarction
    • French P., McGregor J.L., Berruyer M., Belleville J., Touboul P., Dawes J., Dechavanne M. Comparative evaluation of plasma thrombospondin beta- thromboglobulin and platelet factor 4 in acute myocardial infarction. Thromb Res. 39:1985;619-624.
    • (1985) Thromb Res , vol.39 , pp. 619-624
    • French, P.1    McGregor, J.L.2    Berruyer, M.3    Belleville, J.4    Touboul, P.5    Dawes, J.6    Dechavanne, M.7
  • 11
    • 0023907481 scopus 로고
    • Do extra-platelet sources contribute to the plasma level of thrombospondin?
    • Dawes J., Pratt D.A., Dewar M.S., Preston F.E. Do extra-platelet sources contribute to the plasma level of thrombospondin? Thromb Haemost. 59:1988;273-276.
    • (1988) Thromb Haemost , vol.59 , pp. 273-276
    • Dawes, J.1    Pratt, D.A.2    Dewar, M.S.3    Preston, F.E.4
  • 12
    • 0020584883 scopus 로고
    • A radioimmunoassay for thrombospondin, used in a comparative study of thrombospondin, beta-thromboglobulin and platelet factor 4 in healthy volunteers
    • Dawes J., Clemetson K.J., Gogstad G.O., Mcgregor J., Clezardin P., Prowse C.V., Pepper D.S. A radioimmunoassay for thrombospondin, used in a comparative study of thrombospondin, beta-thromboglobulin and platelet factor 4 in healthy volunteers. Thromb Res. 29:1983;569-581.
    • (1983) Thromb Res , vol.29 , pp. 569-581
    • Dawes, J.1    Clemetson, K.J.2    Gogstad, G.O.3    McGregor, J.4    Clezardin, P.5    Prowse, C.V.6    Pepper, D.S.7
  • 13
    • 0022210361 scopus 로고
    • Radioimmunoassay of human platelet thrombospondin: Different patterns of thrombospondin and beta-thromboglobulin antigen secretion and clearance from the circulation
    • Switalska H.I., Niewiarowski S., Tuszynski G.P., Rucinski B., Schmaier A.H., Morinelli T.A., Cierniewski C.S. Radioimmunoassay of human platelet thrombospondin. different patterns of thrombospondin and beta-thromboglobulin antigen secretion and clearance from the circulation J Lab Clin Med. 106:1985;690-700.
    • (1985) J Lab Clin Med , vol.106 , pp. 690-700
    • Switalska, H.I.1    Niewiarowski, S.2    Tuszynski, G.P.3    Rucinski, B.4    Schmaier, A.H.5    Morinelli, T.A.6    Cierniewski, C.S.7
  • 14
    • 0022474655 scopus 로고
    • A monoclonal antibody-based enzyme-linked immunosorbent assay for quantitation of plasma thrombospondin
    • Kao K.J., Klein P.A. A monoclonal antibody-based enzyme-linked immunosorbent assay for quantitation of plasma thrombospondin. Am J Clin Pathol. 86:1986;317-323.
    • (1986) Am J Clin Pathol , vol.86 , pp. 317-323
    • Kao, K.J.1    Klein, P.A.2
  • 15
    • 0003074560 scopus 로고
    • Methods of studying platelet-secreted proteins and the platelet cytoskeleton
    • Tuszynski G.P., Switalska H.I., Knudsen K. Methods of studying platelet-secreted proteins and the platelet cytoskeleton. Mod Methods Pharmacol. 4:1987;267-286.
    • (1987) Mod Methods Pharmacol , vol.4 , pp. 267-286
    • Tuszynski, G.P.1    Switalska, H.I.2    Knudsen, K.3
  • 16
    • 0030791791 scopus 로고    scopus 로고
    • Soluble P-selectin assay: Importance of correct anticoagulant choice
    • Kirk G., McLaren M., Belch J.F. Soluble P-selectin assay. importance of correct anticoagulant choice Platelets. 8:1997;159-162.
    • (1997) Platelets , vol.8 , pp. 159-162
    • Kirk, G.1    McLaren, M.2    Belch, J.F.3
  • 18
    • 0020539177 scopus 로고
    • An avidin-biotin microELISA for rapid measurement of total and allergen-specific human IgE
    • Subba Rao P.V., McCartney-Francis N.L., Metcalfe D.D. An avidin-biotin microELISA for rapid measurement of total and allergen-specific human IgE. J Immunol Methods. 57:1983;71-85.
    • (1983) J Immunol Methods , vol.57 , pp. 71-85
    • Subba Rao, P.V.1    McCartney-Francis, N.L.2    Metcalfe, D.D.3
  • 20
    • 0032959869 scopus 로고    scopus 로고
    • Heparin-coated cardiopulmonary bypass equipment. I. Biocompatibility markers and development of complications in a high-risk population
    • Videm V., Mollnes T.E., Fosse E., Mohr B., Bergh K., Hagve T.A., Aasen A.O., Svennevig J.L. Heparin-coated cardiopulmonary bypass equipment. I. Biocompatibility markers and development of complications in a high-risk population. J Thorac Cardiovasc Surg. 117:1999;794-802.
    • (1999) J Thorac Cardiovasc Surg , vol.117 , pp. 794-802
    • Videm, V.1    Mollnes, T.E.2    Fosse, E.3    Mohr, B.4    Bergh, K.5    Hagve, T.A.6    Aasen, A.O.7    Svennevig, J.L.8
  • 21
    • 0022918233 scopus 로고
    • Incidence and specificity of interference in two-site immunoassays
    • Boscato L.M., Stuart M.C. Incidence and specificity of interference in two-site immunoassays. Clin Chem. 32:1986;1491-1495.
    • (1986) Clin Chem , vol.32 , pp. 1491-1495
    • Boscato, L.M.1    Stuart, M.C.2
  • 23
    • 0021172835 scopus 로고
    • Detection of enhanced in vivo platelet alpha-granule release in different patient groups-comparison of beta-thromboglobulin, platelet factor 4 and thrombospondin assays
    • Lane D.A., Ireland H., Wolff S., Ranasinghe E., Dawes J. Detection of enhanced in vivo platelet alpha-granule release in different patient groups-comparison of beta-thromboglobulin, platelet factor 4 and thrombospondin assays. Thromb Haemost. 52:1984;183-187.
    • (1984) Thromb Haemost , vol.52 , pp. 183-187
    • Lane, D.A.1    Ireland, H.2    Wolff, S.3    Ranasinghe, E.4    Dawes, J.5
  • 24
    • 0025777345 scopus 로고
    • Effects of hemodialysis on platelet-derived thrombospondin
    • Gawaz M.P., Ward R.A. Effects of hemodialysis on platelet-derived thrombospondin. Kidney Int. 40:1991;257-265.
    • (1991) Kidney Int , vol.40 , pp. 257-265
    • Gawaz, M.P.1    Ward, R.A.2
  • 25
    • 0028230743 scopus 로고
    • Platelet factor 4, beta-thromboglobulin and thrombospondin levels in type I diabetes mellitus patients
    • Bayraktar M., Dundar S., Kirazli S., Teletar F. Platelet factor 4, beta-thromboglobulin and thrombospondin levels in type I diabetes mellitus patients. J Int Med Res. 22:1994;90-94.
    • (1994) J Int Med Res , vol.22 , pp. 90-94
    • Bayraktar, M.1    Dundar, S.2    Kirazli, S.3    Teletar, F.4
  • 27
    • 0028331571 scopus 로고
    • Assessment of coagulation factor activation during cardiopulmonary bypass with a new monoclonal antibody
    • Journois D., Mauriat P., Pouard P., Marchot P., Amiral J., Safran D. Assessment of coagulation factor activation during cardiopulmonary bypass with a new monoclonal antibody. J Cardiothorac Vasc Anesth. 8:1994;157-161.
    • (1994) J Cardiothorac Vasc Anesth , vol.8 , pp. 157-161
    • Journois, D.1    Mauriat, P.2    Pouard, P.3    Marchot, P.4    Amiral, J.5    Safran, D.6
  • 30
    • 0025911727 scopus 로고
    • Biocompatibility of extracorporeal circulation. In vitro comparison of heparin-coated and uncoated oxygenator circuits
    • Videm V., Mollnes T.E., Garred P., Svennevig J.L. Biocompatibility of extracorporeal circulation. In vitro comparison of heparin-coated and uncoated oxygenator circuits. J Thorac Cardiovasc Surg. 101:1991;654-660.
    • (1991) J Thorac Cardiovasc Surg , vol.101 , pp. 654-660
    • Videm, V.1    Mollnes, T.E.2    Garred, P.3    Svennevig, J.L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.