메뉴 건너뛰기




Volumn 23, Issue 5, 1999, Pages 237-244

Computer aided surgery with special focus on neuronavigation

Author keywords

Brain tumor; Computer aided surgery; Infrared optical digitizer; Interactive CT MR guided surgery; Navigable operating microscope; Neuronavigation

Indexed keywords

BRAIN; COMPUTERIZED TOMOGRAPHY; INFRARED DEVICES; INTERACTIVE COMPUTER SYSTEMS; MAGNETIC RESONANCE IMAGING; NEUROSURGERY;

EID: 0343517743     PISSN: 08956111     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0895-6111(99)00021-X     Document Type: Conference Paper
Times cited : (21)

References (29)
  • 1
    • 0023217523 scopus 로고
    • Three dimensional digitizer (neuro-navigator): A new equipment for CT guided stereotaxic surgery
    • Watanabe E., Watanabe T., Manaka S., et al. Three dimensional digitizer (neuro-navigator): a new equipment for CT guided stereotaxic surgery. Surg Neurol. 27:1987;543-547.
    • (1987) Surg Neurol , vol.27 , pp. 543-547
    • Watanabe, E.1    Watanabe, T.2    Manaka, S.3
  • 2
    • 0022505393 scopus 로고
    • A frameless stereotaxic integration of computerized tomographic imaging and the operating microscope
    • Roberts D.W., Strohbehn J.W., Hatch J.F., et al. A frameless stereotaxic integration of computerized tomographic imaging and the operating microscope. J Neurosurg. 65:1986;545-549.
    • (1986) J Neurosurg , vol.65 , pp. 545-549
    • Roberts, D.W.1    Strohbehn, J.W.2    Hatch, J.F.3
  • 3
    • 0342411458 scopus 로고
    • Computer aided surgery: Robotik für Hirnoperationen?
    • Reinhardt H., Meyer H., Amrein E. Computer aided surgery: Robotik für Hirnoperationen? Polyscope plus. 6:1986;1-6.
    • (1986) Polyscope Plus , vol.6 , pp. 1-6
    • Reinhardt, H.1    Meyer, H.2    Amrein, E.3
  • 4
    • 0019260540 scopus 로고
    • A computerized microstereotactic method to approach, 3-dimensionally reconstruct, remove and adjuvantly treat small CNS lesions
    • Jacques S., Shelden C.H., McCann G.D. A computerized microstereotactic method to approach, 3-dimensionally reconstruct, remove and adjuvantly treat small CNS lesions. Appl Neurophysiol. 43:1980;176-182.
    • (1980) Appl Neurophysiol , vol.43 , pp. 176-182
    • Jacques, S.1    Shelden, C.H.2    McCann, G.D.3
  • 5
    • 0343716620 scopus 로고
    • Computer assisted stereotactic laser microsurgery for the treatment of intracranial neoplasms
    • Kelly P.J., Alker G.J., Goerss S. Computer assisted stereotactic laser microsurgery for the treatment of intracranial neoplasms. Neurosurgery. 14:1982;172-177.
    • (1982) Neurosurgery , vol.14 , pp. 172-177
    • Kelly, P.J.1    Alker, G.J.2    Goerss, S.3
  • 6
    • 0024202442 scopus 로고
    • A new imaging method for intraoperative therapy control in skullbase surgery
    • Mösges R., Schloendorff G. A new imaging method for intraoperative therapy control in skullbase surgery. Neurosurg Rev. 11:1988;245-247.
    • (1988) Neurosurg Rev , vol.11 , pp. 245-247
    • Mösges, R.1    Schloendorff, G.2
  • 8
    • 0008314684 scopus 로고
    • Three-dimensional CT-interactive "surgical Localizer" for endoscopic sinus surgery and neurosurgery
    • Zinreich S.J., Dekel D., Legget B., et al. Three-dimensional CT-interactive "Surgical Localizer" for endoscopic sinus surgery and neurosurgery. Radiology. 177:1990;217.
    • (1990) Radiology , vol.177 , pp. 217
    • Zinreich, S.J.1    Dekel, D.2    Legget, B.3
  • 9
    • 0027423656 scopus 로고
    • Use of a frameless, armless stereotactic wand for brain tumor localization with 2-D and 3-D neuroimaging
    • Barnett G.H., Kormos D.W., Steiner C.P., et al. Use of a frameless, armless stereotactic wand for brain tumor localization with 2-D and 3-D neuroimaging. Neurosurgery. 33:1993;674-678.
    • (1993) Neurosurgery , vol.33 , pp. 674-678
    • Barnett, G.H.1    Kormos, D.W.2    Steiner, C.P.3
  • 10
    • 0027509182 scopus 로고
    • Ultrasonic stereometry in microsurgical procedures for deep seated brain tumors and vascular malformations
    • Reinhardt H.F., Horstmann G.A., Gratzl O. Ultrasonic stereometry in microsurgical procedures for deep seated brain tumors and vascular malformations. Neurosurgery. 32:1993;51-57.
    • (1993) Neurosurgery , vol.32 , pp. 51-57
    • Reinhardt, H.F.1    Horstmann, G.A.2    Gratzl, O.3
  • 11
    • 0025735799 scopus 로고
    • A frameless, armless navigational system for computer assisted neurosurgery
    • Kato A., Yoshimine T., Hayakawa T., Tomita Y., et al. A frameless, armless navigational system for computer assisted neurosurgery. J Neurosurg. 74:1991;845-849.
    • (1991) J Neurosurg , vol.74 , pp. 845-849
    • Kato, A.1    Yoshimine, T.2    Hayakawa, T.3    Tomita, Y.4
  • 12
    • 0027886352 scopus 로고
    • Intraoperative localization using a three dimensional optical digitizer
    • Bucholz R.D., Smith K.R., Henderson J. Intraoperative localization using a three dimensional optical digitizer. SPIE. 1993;312-322.
    • (1993) SPIE , pp. 312-322
    • Bucholz, R.D.1    Smith, K.R.2    Henderson, J.3
  • 17
    • 0001287782 scopus 로고
    • The viewing wand: A new system for three-dimensional computer tomography-correlated intraoperative localization
    • Leggett W.B., Greenberg M.M., Gannon W.E., et al. The viewing wand: a new system for three-dimensional computer tomography-correlated intraoperative localization. Curr Surg. 48:1991;674-678.
    • (1991) Curr Surg , vol.48 , pp. 674-678
    • Leggett, W.B.1    Greenberg, M.M.2    Gannon, W.E.3
  • 18
    • 0018751133 scopus 로고
    • A computerized tomography-computer graphics approach to stereotaxic localization
    • Brown R.A. A computerized tomography-computer graphics approach to stereotaxic localization. J Neurosurg. 50:1979;715-720.
    • (1979) J Neurosurg , vol.50 , pp. 715-720
    • Brown, R.A.1
  • 19
    • 0343716615 scopus 로고
    • An adapter for computerized tomography-guided stereotaxis
    • Laitinen L.V., Liliequist B., Fagerlund M., et al. An adapter for computerized tomography-guided stereotaxis. Surg Neurol. 34:1985;101-105.
    • (1985) Surg Neurol , vol.34 , pp. 101-105
    • Laitinen, L.V.1    Liliequist, B.2    Fagerlund, M.3
  • 20
    • 0030119410 scopus 로고    scopus 로고
    • Computerunterstützte Chirurgie der Nasennebenhöhlen mit einem optoelektronischen Ortungssystem
    • Hauser R., Westermann B., Reinhardt H., et al. Computerunterstützte Chirurgie der Nasennebenhöhlen mit einem optoelektronischen Ortungssystem. Laryngo-Rhino-Otol. 75:1996;199-207.
    • (1996) Laryngo-Rhino-Otol , vol.75 , pp. 199-207
    • Hauser, R.1    Westermann, B.2    Reinhardt, H.3
  • 21
    • 0001843963 scopus 로고
    • Image registration based on anatomic surface matching
    • R.J. et al. Maciunas. Chigago, IL: American Association of Neurological Surgeons
    • Pelizzari C.A., Levin D.N., Chen G.T.Y., et al. Image registration based on anatomic surface matching. Maciunas R.J., et al. Interactive image-guided neurosurgery. 1993;47-62 American Association of Neurological Surgeons, Chigago, IL.
    • (1993) Interactive Image-guided Neurosurgery , pp. 47-62
    • Pelizzari, C.A.1    Levin, D.N.2    Chen, G.T.Y.3
  • 22
    • 0002375331 scopus 로고    scopus 로고
    • Registration for computer integrated surgery: Methodology, state of the art
    • R. et al. Taylor. Cambridge, MA: MIT Press
    • Lavallèe S., et al. Registration for computer integrated surgery: methodology, state of the art. Taylor R., et al. Computer integrated surgery. 1996;77-97 MIT Press, Cambridge, MA.
    • (1996) Computer Integrated Surgery , pp. 77-97
    • Lavallèe, S.1
  • 23
    • 0028822099 scopus 로고
    • Optically navigable operating microscope for image guided minimally invasive neurosurgery
    • Westermann B., Trippel M., Reinhardt H.F. Optically navigable operating microscope for image guided minimally invasive neurosurgery. Minim Invas Neurosurg. 38:1995;112-116.
    • (1995) Minim Invas Neurosurg , vol.38 , pp. 112-116
    • Westermann, B.1    Trippel, M.2    Reinhardt, H.F.3
  • 24
    • 0342411453 scopus 로고
    • Development of ultrasound guided brain tumour surgery
    • D.G.T. Thomas. Edinburgh, UK: Churchill Livingstone
    • Koivukangas J. Development of ultrasound guided brain tumour surgery. Thomas D.G.T. Stereotactic and image directed surgery of brain tumours. 1993;111-124 Churchill Livingstone, Edinburgh, UK.
    • (1993) Stereotactic and Image Directed Surgery of Brain Tumours , pp. 111-124
    • Koivukangas, J.1
  • 25
    • 0024603605 scopus 로고
    • Surgery of brain neoplasms using 32-P tumour marker
    • Reinhardt H.F. Surgery of brain neoplasms using 32-P tumour marker. Acta Neurochir (Wien). 97:1989;89-94.
    • (1989) Acta Neurochir (Wien) , vol.97 , pp. 89-94
    • Reinhardt, H.F.1
  • 26
    • 0020694242 scopus 로고
    • Computed tomographic guidance stereotaxis in the management of intracranial mass lesions
    • Apuzzo M.L.J., Sabshin J.K. Computed tomographic guidance stereotaxis in the management of intracranial mass lesions. Neurosurgery. 12:1983;277-285.
    • (1983) Neurosurgery , vol.12 , pp. 277-285
    • Apuzzo, M.L.J.1    Sabshin, J.K.2
  • 27
    • 0020875561 scopus 로고
    • Computed tomography guided stereotactic systems
    • Heilbrun M.P. Computed tomography guided stereotactic systems. Clin Neurosurg. 31:1984;564-581.
    • (1984) Clin Neurosurg , vol.31 , pp. 564-581
    • Heilbrun, M.P.1
  • 28
    • 0342846382 scopus 로고
    • Intraoperative imaging with a therapeutic computed tomographic scanner
    • Lunsford L.D., Parish R., Albright L. Intraoperative imaging with a therapeutic computed tomographic scanner. Neurosurgery. 7:1980;376-381.
    • (1980) Neurosurgery , vol.7 , pp. 376-381
    • Lunsford, L.D.1    Parish, R.2    Albright, L.3
  • 29
    • 0002038290 scopus 로고    scopus 로고
    • The vision of image-guided computerized surgery: The hi-tech operating room
    • R. et al. Taylor. Cambridge, MA: MIT Press
    • Jolesz F.A., Kikinis R., Shtern F., et al. The vision of image-guided computerized surgery: the hi-tech operating room. Taylor R., et al. Computer integrated surgery. 1996;717-721 MIT Press, Cambridge, MA.
    • (1996) Computer Integrated Surgery , pp. 717-721
    • Jolesz, F.A.1    Kikinis, R.2    Shtern, F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.