Volumn 47, Issue 5-6, 1996, Pages 535-541

Dependence of photon interaction depth on linear attenuation coefficient in high pure germanium detectors

Author keywords

[No Author keywords available]

Indexed keywords

CALCULATIONS; CRYSTALS; GAMMA RAY SPECTROMETERS; GAMMA RAYS; GERMANIUM;

EID: 0343183032     PISSN: 09698043     EISSN: None     Source Type: Journal    
DOI: 10.1016/0969-8043(95)00325-8     Document Type: Article
Times cited : (10)

References (11)
  • 1
    • 0006197085 scopus 로고
    • A technique of γ-ray detector absolute efficiency calibration for extended sources
    • CONF-780421, Mayaguez, Puerto Rico
    • Cline J. E. (1979) A technique of γ-ray detector absolute efficiency calibration for extended sources. In Proc. Am. Nucl. Soc. Topical Conf. Computers Activat. Analysis γ-ray Spectrosc. CONF-780421, p. 185. Mayaguez, Puerto Rico.
    • (1979) Proc. Am. Nucl. Soc. Topical Conf. Computers Activat. Analysis γ-ray Spectrosc , pp. 185
    • Cline, J.E.1
  • 2
    • 0343722760 scopus 로고
    • A method for absolute calibration of Ge(Li) detectors using effective interaction depth
    • Crisler D. F., Jarmer J. J. and Eldridge H. B. (1971) A method for absolute calibration of Ge(Li) detectors using effective interaction depth. Nucl. Instrum. Meth. 94, 285.
    • (1971) Nucl. Instrum. Meth. , vol.94 , pp. 285
    • Crisler, D.F.1    Jarmer, J.J.2    Eldridge, H.B.3
  • 4
    • 0018293171 scopus 로고
    • Coincidence summing corrections in Ge(Li)-spectrometry at low source-to-detector distances
    • Debertin K. and Schötzig U. (1979) Coincidence summing corrections in Ge(Li)-spectrometry at low source-to-detector distances. Nucl. Instrum. Meth. 158, 471.
    • (1979) Nucl. Instrum. Meth. , vol.158 , pp. 471
    • Debertin, K.1    Schötzig, U.2
  • 5
    • 0017322823 scopus 로고
    • Efficiency calibration of semiconductor spectrometers-techniques and accuracies
    • Ann Arbor, MI. (edited by Griffin H. C.), CONF-760539 National Technical Information Service, Springfield, VA
    • Debertin K., Schötzig U., Walz K. F. and WeiB H. H. (1976) Efficiency calibration of semiconductor spectrometers-techniques and accuracies. In Proc. ERDA Symp. X-and γ-Ray Sources Applic. Ann Arbor, MI. (edited by Griffin H. C.), CONF-760539 p. 59. National Technical Information Service, Springfield, VA.
    • (1976) Proc. ERDA Symp. X-and γ-ray Sources Applic , pp. 59
    • Debertin, K.1    Schötzig, U.2    Walz, K.F.3    WeiB, H.H.4
  • 6
    • 33646278008 scopus 로고
    • New method for calibrating a Ge detector by using only zero to four efficiency points
    • Gunnink R. (1990) New method for calibrating a Ge detector by using only zero to four efficiency points. Nucl. Instrum. Meth. Phys. Res. A299, 372.
    • (1990) Nucl. Instrum. Meth. Phys. Res. , vol.A299 , pp. 372
    • Gunnink, R.1
  • 7
    • 0020165477 scopus 로고
    • Efficiency calibration of a Ge detector for 30-2800 keV γ-rays
    • Helmer R. G. (1982) Efficiency calibration of a Ge detector for 30-2800 keV γ-rays. Nucl. Instrum. Meth. 199, 521.
    • (1982) Nucl. Instrum. Meth. , vol.199 , pp. 521
    • Helmer, R.G.1
  • 8
    • 0017322196 scopus 로고
    • Germanium detector efficiency calibration with nbs standards
    • Ann Arbor, MI. (edited by Griffin H. C.), CONF-760539, National Technical Information Service, Springfield, VA
    • Hirshfeld A. T., Hoppes D. D. and Schima F. J. (1976) Germanium detector efficiency calibration with NBS standards. In Proc. ERDA Symp. X-and γ-Ray Sources Applic. Ann Arbor, MI. (edited by Griffin H. C.), CONF-760539, p. 90. National Technical Information Service, Springfield, VA.
    • (1976) Proc. ERDA Symp. X-and γ-ray Sources Applic. , pp. 90
    • Hirshfeld, A.T.1    Hoppes, D.D.2    Schima, F.J.3
  • 9
    • 0020213666 scopus 로고
    • Photon mass attenuation and energy absorption coefficients from 1 keV to 20 MeV
    • Hubbel J. H. (1982) Photon mass attenuation and energy absorption coefficients from 1 keV to 20 MeV. Int. J. Appl. Radiat. Isot. 33, 1269.
    • (1982) Int. J. Appl. Radiat. Isot. , vol.33 , pp. 1269
    • Hubbel, J.H.1
  • 10
    • 0000052857 scopus 로고
    • The Ge(Li) spectrometer as a point detector
    • Notea A. (1971) The Ge(Li) spectrometer as a point detector. Nucl. Instrum. Meth. 91, 513.
    • (1971) Nucl. Instrum. Meth. , vol.91 , pp. 513
    • Notea, A.1
  • 11
    • 0023104912 scopus 로고
    • The efficiencies of different photon detectors. A review covering work done between 1975 and 1985
    • Rieppo R. (1987) The efficiencies of different photon detectors. A review covering work done between 1975 and 1985. Appl. Radiat. Isot. 38, 1.
    • (1987) Appl. Radiat. Isot. , vol.38 , pp. 1
    • Rieppo, R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.