메뉴 건너뛰기




Volumn 3032, Issue , 1997, Pages 88-96

Radiographic imaging characteristics of a direct conversion detector using selenium and thin film transistor array

Author keywords

Digital; Electronic; Medical imaging; Radiography; Selenium; Thin film transistor array; X rays

Indexed keywords

AMORPHOUS SILICON; DETECTORS; ELECTRIC FIELDS; ELECTRIC SIGNAL SYSTEMS; IMAGE ANALYSIS; MICROMETERS; MODULATION; NONMETALS; PIXELS; RADIOGRAPHY; RADIOLOGY; SELENIUM; SEMICONDUCTING SELENIUM COMPOUNDS; SEMICONDUCTING SILICON COMPOUNDS; SEMICONDUCTOR QUANTUM DOTS; SENSORS; THICKNESS MEASUREMENT; THIN FILM DEVICES; THIN FILM TRANSISTORS; TRANSISTORS; X RAY RADIOGRAPHY;

EID: 0343132877     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.273973     Document Type: Conference Paper
Times cited : (32)

References (12)
  • 1
    • 0028921566 scopus 로고
    • Effects of undersamplmg on the proper interpretation of modulation transfer function, noise power spectra, and noise equivalent quanta of digital imaging systems
    • February
    • James T. Dobbins III, 'Effects of undersamplmg on the proper interpretation of modulation transfer function, noise power spectra, and noise equivalent quanta of digital imaging systems', Med. Phys. 22 (2), February 1995.
    • (1995) Med. Phys , vol.22 , Issue.2
    • Dobbins III, J.T.1
  • 2
    • 0023439378 scopus 로고
    • Fourier spectrum techniques for the characterization of spatial noise in imaging arrays
    • October
    • Glenn D. Boreman, 'Fourier spectrum techniques for the characterization of spatial noise in imaging arrays', Optical Engineering Vol. 26 No. 10 ,October 1987.
    • (1987) Optical Engineering , vol.26 , Issue.10
    • Boreman, G.D.1
  • 3
    • 0028020650 scopus 로고
    • An analytical edge spread function model for computer fitting and subsequent calculation of the LSF and MTF
    • October
    • John M. Boone, and J. Anthony Seibert, 'An analytical edge spread function model for computer fitting and subsequent calculation of the LSF and MTF', Med. Phys. 21 (10), October 1994.
    • (1994) Med. Phys , vol.21 , Issue.10
    • Boone, J.M.1    Anthony Seibert, J.2
  • 4
    • 0029458793 scopus 로고    scopus 로고
    • D. L. Lee, L. K. Cheung, and L. S. Jeromin, 'A New Digital Detector for Projection Radiography', SPIE, 2432, Physics of Medical Imaging, (1995) 237-
    • D. L. Lee, L. K. Cheung, and L. S. Jeromin, 'A New Digital Detector for Projection Radiography', SPIE, Vol. 2432, Physics of Medical Imaging, (1995) 237-
  • 5
    • 0029712682 scopus 로고    scopus 로고
    • A Discussion on Resolution and Dynamic Range of a Se-TFT Direct digital Radiography Detector
    • Denny L. Lee, Lawrence K. Cheung, Eugene F. Palecki, and Lothar Jeromin, 'A Discussion on Resolution and Dynamic Range of a Se-TFT Direct digital Radiography Detector', SPIE Vol. 2708 (1996) 511-522.
    • (1996) SPIE , vol.2708 , pp. 511-522
    • Lee, D.L.1    Cheung, L.K.2    Palecki, E.F.3    Jeromin, L.4
  • 6
    • 0018531706 scopus 로고    scopus 로고
    • J. L. Donovan, J. Appl. Phys., 'X-ray sensitivity of selenium', 50, No. 10, (October 1979) 6500-6504.
    • J. L. Donovan, J. Appl. Phys., 'X-ray sensitivity of selenium', Vol. 50, No. 10, (October 1979) 6500-6504.
  • 7
    • 0026697398 scopus 로고
    • X-ray imaging using amorphous selenium: Determination of x-ray sensitivity by pulse height spectroscopy
    • Jul/Aug
    • J. A. Rowlands, G. DeCrescenzo, N. Araj, 'X-ray imaging using amorphous selenium: Determination of x-ray sensitivity by pulse height spectroscopy', Med. Phys. 19(4), (Jul/Aug 1992) 1065-1069.
    • (1992) Med. Phys , vol.19 , Issue.4 , pp. 1065-1069
    • Rowlands, J.A.1    DeCrescenzo, G.2    Araj, N.3
  • 9
    • 0004288151 scopus 로고
    • See, Academic Press () by J. C. Dainty and R. Shaw
    • See Image Science, Academic Press (1974) by J. C. Dainty and R. Shaw page 156.
    • (1974) Image Science , pp. 156
  • 10
    • 0027199280 scopus 로고
    • The image quality characteristics of a novel ultra-high-resolution film/screen system
    • J. Beutel, D. J. Mickewich, S. L. Issler, and R. Shaw, 'The image quality characteristics of a novel ultra-high-resolution film/screen system', Phys. Med. Biol. 38 (1993) 1195-1206.
    • (1993) Phys. Med. Biol , vol.38 , pp. 1195-1206
    • Beutel, J.1    Mickewich, D.J.2    Issler, S.L.3    Shaw, R.4
  • 11
    • 0028840692 scopus 로고
    • DQE(f) of four generations of computed radiography acquisition devices
    • October
    • James T. Dobbins III, David L. Ergun, Lois Rutz, Dean A. Hinshaw, Hartwig Blume, Dwayne C. Clarke, DQE(f) of four generations of computed radiography acquisition devices, Med Phys. 22 (10), October 1995.
    • (1995) Med Phys , vol.22 , Issue.10
    • Dobbins III, J.T.1    Ergun, D.L.2    Rutz, L.3    Hinshaw, D.A.4    Blume, H.5    Clarke, D.C.6
  • 12
    • 0004288151 scopus 로고
    • See, Academic Press () by J. C. Dainty and R. Shaw
    • See Image Science, Academic Press (1974) by J. C. Dainty and R. Shaw page 312.
    • (1974) Image Science , pp. 312


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.