Compact compliance chamber design for the study of cardiac performance in microgravity

Author keywords

[No Author keywords available]

Indexed keywords

CARDIOVASCULAR SYSTEM; EQUIPMENT TESTING; GRAVITATIONAL EFFECTS; STIFFNESS; WEIGHTLESSNESS;

EID: 0343118771     PISSN: 10582916     EISSN: None     Source Type: Journal    
DOI: 10.1097/00002480-199743040-00010     Document Type: Article
Times cited : (13)

References (9)
  • 1
    • 0343188680 scopus 로고
    • Mock circulation to test pumps designed for permanent replacement of damaged hearts
    • Kolff WJ: Mock circulation to test pumps designed for permanent replacement of damaged hearts. Cleve Clin Q 26: 223-226, 1959.
    • (1959) Cleve Clin Q , vol.26 , pp. 223-226
    • Kolff, W.J.1
  • 2
    • 0343624261 scopus 로고
    • Hydrospace Research Corporation: Final report on the mock circulatory system
    • Hydrospace Research Corporation: Final report on the mock circulatory system. NIH Contract PH-43-64-78, 1967.
    • (1967) NIH Contract PH-43-64-78
  • 3
    • 0019799237 scopus 로고
    • Design and evaluation of the Pennsylvania State University mock circulatory system
    • Rosenberg G, Phillips WM, Landis DL, Pierce WS: Design and evaluation of the Pennsylvania State University mock circulatory system. ASAIO J 4: 41-49, 1981.
    • (1981) ASAIO J , vol.4 , pp. 41-49
    • Rosenberg, G.1    Phillips, W.M.2    Landis, D.L.3    Pierce, W.S.4
  • 4
    • 0345029793 scopus 로고
    • Echocardiographic Changes Related to Space Travel
    • Schapira JN, Harold JG (eds), William & Wilkins, Baltimore
    • Bungo MW: Echocardiographic Changes Related to Space Travel, in Schapira JN, Harold JG (eds), Two-Dimensional Echocardiography and Cardiac Doppler, 2nd ed, William & Wilkins, Baltimore, 1990, pp. 524-529.
    • (1990) Two-Dimensional Echocardiography and Cardiac Doppler, 2nd Ed , pp. 524-529
    • Bungo, M.W.1
  • 6
    • 0016617573 scopus 로고
    • Design of a hydraulic analog of the circulatory system for evaluating artificial hearts
    • Donovan FM Jr: Design of a hydraulic analog of the circulatory system for evaluating artificial hearts. Biomater Med Devices Artif Organs 3: 439, 1975.
    • (1975) Biomater Med Devices Artif Organs , vol.3 , pp. 439
    • Donovan Jr., F.M.1
  • 7
    • 0019799237 scopus 로고
    • Design and evaluation of the Pennsylvania State University mock circulatory system
    • Rosenberg G, Phillips WM, Landis DL, Pierce WS: Design and evaluation of the Pennsylvania State University mock circulatory system. ASAIO J 4: 41-49, 1981.
    • (1981) ASAIO J , vol.4 , pp. 41-49
    • Rosenberg, G.1    Phillips, W.M.2    Landis, D.L.3    Pierce, W.S.4
  • 8
    • 0343624259 scopus 로고
    • Spring
    • McMaster-Carr Supply Company, McMaster-Carr Catalog, Spring 1993, pp. 2632-2635.
    • (1993) McMaster-Carr Catalog , pp. 2632-2635
  • 9
    • 0343624258 scopus 로고
    • Total artificial heart development at the University of Utah: The Utah-100 and electrohydraulic cardiac replacement devices
    • S Quaal (ed): Mosby-Year Book
    • White RK, Pantalos GM, Olson DB: Total artificial heart development at the University of Utah: the Utah-100 and electrohydraulic cardiac replacement devices, in S Quaal (ed): Cardiac Mechanical Assistance Beyond Balloon Pumping. Mosby-Year Book, 1992, pp. 181-193.
    • (1992) Cardiac Mechanical Assistance Beyond Balloon Pumping , pp. 181-193
    • White, R.K.1    Pantalos, G.M.2    Olson, D.B.3