메뉴 건너뛰기




Volumn 93, Issue 1 SUPPL., 2000, Pages 40-44

New method for intraoperative determination of proper screw insertion or screw malposition

Author keywords

Pedicle; Screw fixation; Screw malposition; Spine injury

Indexed keywords

ADULT; ARTICLE; BONE SCREW; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; DIAGNOSTIC IMAGING; FEMALE; HUMAN; MALE; MATHEMATICAL ANALYSIS; PRIORITY JOURNAL; SPINE INJURY; SPINE STABILIZATION; SURGICAL TECHNIQUE; THORACOLUMBAR SPINE;

EID: 0343081625     PISSN: 00223085     EISSN: None     Source Type: Journal    
DOI: 10.3171/spi.2000.93.1.0040     Document Type: Article
Times cited : (16)

References (17)
  • 1
    • 0031417450 scopus 로고    scopus 로고
    • Anatomic relations of the thoracic pedicle to the adjacent neural structures
    • Ebraheim NA, Jabaly G, Xu R, et al: Anatomic relations of the thoracic pedicle to the adjacent neural structures, Spine 22: 1553-1557, 1997
    • (1997) Spine , vol.22 , pp. 1553-1557
    • Ebraheim, N.A.1    Jabaly, G.2    Xu, R.3
  • 2
    • 0031045340 scopus 로고    scopus 로고
    • Projection of the thoracic pedicle and its morphometric analysis
    • Ebraheim NA, Xu R, Ahmad M, et al: Projection of the thoracic pedicle and its morphometric analysis. Spine 22:233-238, 1997
    • (1997) Spine , vol.22 , pp. 233-238
    • Ebraheim, N.A.1    Xu, R.2    Ahmad, M.3
  • 3
    • 0031410282 scopus 로고    scopus 로고
    • Anatomic relations between the lumbar pedicle and the adjacent neural structures
    • Ebraheim NA, Xu R, Darwich M, et al: Anatomic relations between the lumbar pedicle and the adjacent neural structures. Spine 22:2338-2341, 1997
    • (1997) Spine , vol.22 , pp. 2338-2341
    • Ebraheim, N.A.1    Xu, R.2    Darwich, M.3
  • 4
    • 0029893644 scopus 로고    scopus 로고
    • Accuracy of pedicle screw placement in lumbar vertebrae
    • Castro WH, Hahn H, Jerosch J, et al: Accuracy of pedicle screw placement in lumbar vertebrae. Spine 21:1320-1324, 1996
    • (1996) Spine , vol.21 , pp. 1320-1324
    • Castro, W.H.1    Hahn, H.2    Jerosch, J.3
  • 5
    • 0026439770 scopus 로고
    • Transpedicular screw-rod fixation of the lumbar spine: Operative technique and outcome in 104 cases
    • Dickman CA, Fessier GR, MacMillan M, et al: Transpedicular screw-rod fixation of the lumbar spine: operative technique and outcome in 104 cases. J Neurosurg 77:860-870, 1992
    • (1992) J Neurosurg , vol.77 , pp. 860-870
    • Dickman, C.A.1    Fessier, G.R.2    MacMillan, M.3
  • 6
    • 0032532750 scopus 로고    scopus 로고
    • Fatal cardiac tamponade associated with posterior spinal instrumentation. A case report
    • Heini P, Scholl E, Wyler D, et al: Fatal cardiac tamponade associated with posterior spinal instrumentation. A case report. Spine 23:2226-2230, 1998
    • (1998) Spine , vol.23 , pp. 2226-2230
    • Heini, P.1    Scholl, E.2    Wyler, D.3
  • 7
    • 0029157802 scopus 로고
    • Application of frameless stereotaxy to pedicle screw fixation of the spine
    • Kalfas IH, Kormos DW, Murphy MA, et al: Application of frameless stereotaxy to pedicle screw fixation of the spine. J Neurosurg 83:641-647, 1995
    • (1995) J Neurosurg , vol.83 , pp. 641-647
    • Kalfas, I.H.1    Kormos, D.W.2    Murphy, M.A.3
  • 8
    • 0031426455 scopus 로고    scopus 로고
    • Multidirectional instability of the thoracic spine due to iatrogenic pedicle injuries during transpedicular fixation. A biomechanical investigation
    • Kothe R, Panjabi MM, Liu W: Multidirectional instability of the thoracic spine due to iatrogenic pedicle injuries during transpedicular fixation. A biomechanical investigation. Spine 22:1836-1842, 1997
    • (1997) Spine , vol.22 , pp. 1836-1842
    • Kothe, R.1    Panjabi, M.M.2    Liu, W.3
  • 9
    • 0030926450 scopus 로고    scopus 로고
    • Improved accuracy of pedicle screw insertion with computer-assisted surgery. A prospective clinical trial of 30 patients
    • Laine T, Schlenzka D, Makitalo K, et al: Improved accuracy of pedicle screw insertion with computer-assisted surgery. A prospective clinical trial of 30 patients. Spine 22:1254-1258, 1997
    • (1997) Spine , vol.22 , pp. 1254-1258
    • Laine, T.1    Schlenzka, D.2    Makitalo, K.3
  • 10
    • 0026700707 scopus 로고
    • Management of thoracolumbar fractures with accompanying neurological injury
    • Lemons VR, Wagner FC, Montesano PX: Management of thoracolumbar fractures with accompanying neurological injury. Neurosurgery 30:667-671, 1992
    • (1992) Neurosurgery , vol.30 , pp. 667-671
    • Lemons, V.R.1    Wagner, F.C.2    Montesano, P.X.3
  • 11
    • 0031750966 scopus 로고    scopus 로고
    • Efficacy of pedicle screw fixation in the treatment of spinal instability and failed back surgery: A 5-year review
    • Masferrer R, Gomez HG, Karahalios DG, et al: Efficacy of pedicle screw fixation in the treatment of spinal instability and failed back surgery: a 5-year review. J Neurosurg 89:371-377, 1998
    • (1998) J Neurosurg , vol.89 , pp. 371-377
    • Masferrer, R.1    Gomez, H.G.2    Karahalios, D.G.3
  • 12
    • 0030945156 scopus 로고    scopus 로고
    • Computer assisted spine surgery
    • Merloz P, Tonetti J, Eid A, et al: Computer assisted spine surgery. Clin Orthop 337:86-96, 1997
    • (1997) Clin Orthop , vol.337 , pp. 86-96
    • Merloz, P.1    Tonetti, J.2    Eid, A.3
  • 13
    • 0028920648 scopus 로고
    • Image-guided insertion of transpedicular screws. A laboratory set-up
    • Nolte LP, Zamorano LJ, Jiang Z, et al: Image-guided insertion of transpedicular screws. A laboratory set-up. Spine 20: 497-500, 1995
    • (1995) Spine , vol.20 , pp. 497-500
    • Nolte, L.P.1    Zamorano, L.J.2    Jiang, Z.3
  • 14
    • 0028600649 scopus 로고
    • Complications after transpedicular stabilization of the spine. A survivorship analysis of 163 cases
    • Ohlin A, Karlsson M, Düppe H, et al: Complications after transpedicular stabilization of the spine. A survivorship analysis of 163 cases. Spine 19:2774-2779, 1994
    • (1994) Spine , vol.19 , pp. 2774-2779
    • Ohlin, A.1    Karlsson, M.2    Düppe, H.3
  • 15
    • 0031016431 scopus 로고    scopus 로고
    • Selection criteria and outcome of operative approaches for thoracolumbar burst fractures with and without neurological deficit
    • Schnee CL, Ansell LV: Selection criteria and outcome of operative approaches for thoracolumbar burst fractures with and without neurological deficit. J Neurosurg 86:48-55, 1997
    • (1997) J Neurosurg , vol.86 , pp. 48-55
    • Schnee, C.L.1    Ansell, L.V.2
  • 16
    • 0027252714 scopus 로고
    • CT analysis of pedicle and screw tracts after implant removal in thoracolumbar fractures
    • Sjostrom L, Jacobsson O, Karlstrom G, et al: CT analysis of pedicle and screw tracts after implant removal in thoracolumbar fractures. J Spinal Disord 6:225-231, 1993
    • (1993) J Spinal Disord , vol.6 , pp. 225-231
    • Sjostrom, L.1    Jacobsson, O.2    Karlstrom, G.3
  • 17
    • 0342297668 scopus 로고    scopus 로고
    • Thoracic and lumbar fusion: Techniques for posterior stabilization
    • Menezes AH (ed): New York: McGraw-Hill
    • Stillerman CB, Gruen JP, Roy R: Thoracic and lumbar fusion: techniques for posterior stabilization, in Menezes AH (ed): Principles of Spinal Surgery. New York: McGraw-Hill, 1996, Vol 2, pp 1199-1225
    • (1996) Principles of Spinal Surgery , vol.2 , pp. 1199-1225
    • Stillerman, C.B.1    Gruen, J.P.2    Roy, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.