-
1
-
-
0023945852
-
Corneal topography using computer analyzed rasterstereographic images
-
Warnicki JW, Rehkopf PG, Curtin SA, et al: Corneal topography using computer analyzed rasterstereographic images. Applied Optics 1988; 27:1135-1140.
-
(1988)
Applied Optics
, vol.27
, pp. 1135-1140
-
-
Warnicki, J.W.1
Rehkopf, P.G.2
Curtin, S.A.3
-
4
-
-
0027536610
-
Accuracy of the PAR corneal topography system with spatial misalignment
-
Belin MW, Zloty P: Accuracy of the PAR Corneal Topography System with spatial misalignment. CLAO J 1993;19:64-68.
-
(1993)
CLAO J
, vol.19
, pp. 64-68
-
-
Belin, M.W.1
Zloty, P.2
-
5
-
-
0027176589
-
Intraoperative raster photogrammetry-the PAR corneal topography system
-
Belin MW: Intraoperative raster photogrammetry-the PAR Corneal Topography System. J Cataract Refract Surg 1993;19 (suppl):188-192.
-
(1993)
J Cataract Refract Surg
, vol.19
, Issue.SUPPL.
, pp. 188-192
-
-
Belin, M.W.1
-
6
-
-
0028784052
-
PAR corneal topography system (PAR CTS): The clinical application of close-range photogrammetry
-
Belin MW, Cambier JL, Nabors JR, Ratliff CD: PAR Corneal Topography System (PAR CTS): The clinical application of close-range photogrammetry. Optom Vis Sci 1995;72:828-837.
-
(1995)
Optom Vis Sci
, vol.72
, pp. 828-837
-
-
Belin, M.W.1
Cambier, J.L.2
Nabors, J.R.3
Ratliff, C.D.4
-
7
-
-
0024335622
-
Accuracy and precision of keratometry, photokeratoscopy, and corneal modeling on calibrated steel balls
-
Hannush SB, Crawford SL, Waring GO, et al: Accuracy and precision of keratometry, photokeratoscopy, and corneal modeling on calibrated steel balls. Arch Ophthalmol 1989;107:1235-1239.
-
(1989)
Arch Ophthalmol
, vol.107
, pp. 1235-1239
-
-
Hannush, S.B.1
Crawford, S.L.2
Waring, G.O.3
-
8
-
-
0025305331
-
Reproducibility of normal corneal power measurements with a keratometer, photokeratoscope, and video imaging system
-
Hannush SB, Crawford SL, Waring GO, et al: Reproducibility of normal corneal power measurements with a keratometer, photokeratoscope, and video imaging system. Arch Ophthalmol 1990;108: 539-544.
-
(1990)
Arch Ophthalmol
, vol.108
, pp. 539-544
-
-
Hannush, S.B.1
Crawford, S.L.2
Waring, G.O.3
-
9
-
-
0024957297
-
The EyeSys corneal analysis system accuracy and reproducibility of first-generation prototype
-
Koch DD, Foulks G, Moran C, Wakil J: The EyeSys corneal analysis system accuracy and reproducibility of first-generation prototype. Refract Corneal Surg 1989;5:424-429.
-
(1989)
Refract Corneal Surg
, vol.5
, pp. 424-429
-
-
Koch, D.D.1
Foulks, G.2
Moran, C.3
Wakil, J.4
-
10
-
-
0026332985
-
Comparison of keratometric readings as obtained by Javal ophthalmometer and corneal analysis system (EyeSys)
-
Tsilimbaris MK, Vlachonikolis IG, Siganos D, et al: Comparison of keratometric readings as obtained by Javal ophthalmometer and corneal analysis system (EyeSys). Refract Corneal Surg 1991;7:368-373.
-
(1991)
Refract Corneal Surg
, vol.7
, pp. 368-373
-
-
Tsilimbaris, M.K.1
Vlachonikolis, I.G.2
Siganos, D.3
-
11
-
-
0026970445
-
Comparison of the accuracy and reproducibility of the keratometer and the EyoSys corneal analysis system model I
-
Koch DD, Wakil JS, Samuelson SW, Haft EA: Comparison of the accuracy and reproducibility of the keratometer and the EyoSys corneal analysis system model I. J Cataract Refract Surg 1992;18:342-347.
-
(1992)
J Cataract Refract Surg
, vol.18
, pp. 342-347
-
-
Koch, D.D.1
Wakil, J.S.2
Samuelson, S.W.3
Haft, E.A.4
-
12
-
-
0026565702
-
Accuracy and precision cf the comeal analysis system and the topographic modeling system
-
Wilson SE, Verity SM, Conger DL: Accuracy and precision cf the comeal analysis system and the topographic modeling system. Cornea 1992;11:28-35.
-
(1992)
Cornea
, vol.11
, pp. 28-35
-
-
Wilson, S.E.1
Verity, S.M.2
Conger, D.L.3
-
13
-
-
84908219488
-
Statistical methods for assessing agreenent between two methods of clinical measurement
-
Bland JM, Altman DG: Statistical methods for assessing agreenent between two methods of clinical measurement. The Lancet 1986; 8: 307-310.
-
(1986)
The Lancet
, vol.8
, pp. 307-310
-
-
Bland, J.M.1
Altman, D.G.2
-
14
-
-
0030908672
-
Comparison of keratometric values of healthy and diseased eyes measured by Javal keratometer, EyeSys, and PAR
-
Varssano D, Rapuano CJ, Luchs JI: Comparison of keratometric values of healthy and diseased eyes measured by Javal keratometer, EyeSys, and PAR. J Cataract Refract Surg 1997; 23: 419-422.
-
(1997)
J Cataract Refract Surg
, vol.23
, pp. 419-422
-
-
Varssano, D.1
Rapuano, C.J.2
Luchs, J.I.3
-
15
-
-
0027202698
-
Preliminary results of a new intraoperative corneal topography technique
-
Thall EH, Lange SR: Preliminary results of a new intraoperative corneal topography technique. J Cataract Refract Surg 1993; 19 (suppl): 193-197.
-
(1993)
J Cataract Refract Surg
, vol.19
, Issue.SUPPL.
, pp. 193-197
-
-
Thall, E.H.1
Lange, S.R.2
-
16
-
-
0028905209
-
Videokeratography
-
Binder PS: Videokeratography (Review). CLAO J 1995; 21 133-144.
-
(1995)
CLAO J
, vol.21
, pp. 133-144
-
-
Binder, P.S.1
-
17
-
-
0027943021
-
The accuracy of 'power' maps to display curvature data in corneal topography systems
-
Roberts C: The accuracy of 'power' maps to display curvature data in corneal topography systems. Invest Ophthalmol Vis Sci 1994; 35: 3525-3532.
-
(1994)
Invest Ophthalmol Vis Sci
, vol.35
, pp. 3525-3532
-
-
Roberts, C.1
|