메뉴 건너뛰기




Volumn 43, Issue 1, 1997, Pages 89-91

Chronic left ventricular assist in calves with a pulsatile impeller pump

Author keywords

[No Author keywords available]

Indexed keywords

BEARINGS (MACHINE PARTS); CARDIOVASCULAR SYSTEM; LIVING SYSTEMS STUDIES; PHYSIOLOGICAL MODELS; PUMPS;

EID: 0342711172     PISSN: 10582916     EISSN: None     Source Type: Journal    
DOI: 10.1097/00002480-199743010-00015     Document Type: Article
Times cited : (14)

References (14)
  • 1
    • 0024511589 scopus 로고
    • The realization of a pulsatile implantable impeller pump with low hemolysis
    • Qian KX, Fei Q, Lin KD, et al: The realization of a pulsatile implantable impeller pump with low hemolysis. Artif Organs 13: 162-169, 1989.
    • (1989) Artif Organs , vol.13 , pp. 162-169
    • Qian, K.X.1    Fei, Q.2    Lin, K.D.3
  • 2
    • 0024017539 scopus 로고
    • Haemolysis test of non-pulsatile and pulsatile impeller blood pumps
    • Qian KX, Fei Q: Haemolysis test of non-pulsatile and pulsatile impeller blood pumps. Clin Phys Physio Meas 9: 107-112, 1988.
    • (1988) Clin Phys Physio Meas , vol.9 , pp. 107-112
    • Qian, K.X.1    Fei, Q.2
  • 3
    • 0023750296 scopus 로고
    • A new impeller blood pump design: In vitro and in vivo studies
    • Qian KX, Jin YA, Lin KD, et al: A new impeller blood pump design: In vitro and in vivo studies. Perfusion 3: 233-240, 1988.
    • (1988) Perfusion , vol.3 , pp. 233-240
    • Qian, K.X.1    Jin, Y.A.2    Lin, K.D.3
  • 4
    • 0028928070 scopus 로고
    • In vivo studies of pulsatile implantable impeller assist and total hearts
    • Qian KX, Wang SS, Chu SH: In vivo studies of pulsatile implantable impeller assist and total hearts. Artif Organs 19: 328-333, 1995.
    • (1995) Artif Organs , vol.19 , pp. 328-333
    • Qian, K.X.1    Wang, S.S.2    Chu, S.H.3
  • 5
    • 0029125412 scopus 로고
    • In vivo testing of a pulsatile implantable impeller pump as a left ventricular assist device used in calves
    • Qian KX, Wang SS, Chu SH: In vivo testing of a pulsatile implantable impeller pump as a left ventricular assist device used in calves. Perfusion 10: 257-263, 1995.
    • (1995) Perfusion , vol.10 , pp. 257-263
    • Qian, K.X.1    Wang, S.S.2    Chu, S.H.3
  • 6
    • 0028472578 scopus 로고
    • Haematological variations in pigs during experimental left ventricular assistance with a pulsatile impeller pump
    • Qian KX, Wang SS, Chu SH: Haematological variations in pigs during experimental left ventricular assistance with a pulsatile impeller pump. Med Eng Phys 16: 348-350, 1994.
    • (1994) Med Eng Phys , vol.16 , pp. 348-350
    • Qian, K.X.1    Wang, S.S.2    Chu, S.H.3
  • 7
    • 0024764154 scopus 로고
    • Low haemolysis pulsatile impeller pump: Design concepts and experimental results
    • Qian KX: Low haemolysis pulsatile impeller pump: Design concepts and experimental results. J Biomed Eng 11: 478-481, 1989.
    • (1989) J Biomed Eng , vol.11 , pp. 478-481
    • Qian, K.X.1
  • 8
    • 0025144791 scopus 로고
    • Haemodynamic approach to reducing thrombosis and haemolysis in an impeller pump
    • Qian KX: Haemodynamic approach to reducing thrombosis and haemolysis in an impeller pump. J Biomed Eng 12: 533-535, 1990.
    • (1990) J Biomed Eng , vol.12 , pp. 533-535
    • Qian, K.X.1
  • 9
    • 0030052416 scopus 로고    scopus 로고
    • Pulsatile implantable impeller heart: A viable alternative to problematic diaphragm heart
    • Qian KX: Pulsatile implantable impeller heart: A viable alternative to problematic diaphragm heart. Med Eng Phys 18: 57-66, 1996.
    • (1996) Med Eng Phys , vol.18 , pp. 57-66
    • Qian, K.X.1
  • 10
    • 0343485906 scopus 로고
    • Design of a long-term implantable magnetically suspended continuous flow ventricular assist device
    • Olsen D: Design of a long-term implantable magnetically suspended continuous flow ventricular assist device (Abstract). Book of ASAIO, 1995.
    • (1995) Book of ASAIO
    • Olsen, D.1
  • 11
    • 0029079971 scopus 로고
    • Seal-less centrifugal blood pump with magnetically suspended rotor: Rot-a-Flot
    • Mendler N, Podechtl F, Feil G, et al: Seal-less centrifugal blood pump with magnetically suspended rotor: Rot-a-Flot. Artif Organs 19: 620-624, 1995.
    • (1995) Artif Organs , vol.19 , pp. 620-624
    • Mendler, N.1    Podechtl, F.2    Feil, G.3
  • 12
    • 0029159808 scopus 로고
    • Design of a centrifugal blood pump with magnetic suspension
    • Yamane T, Ikeda T, Orita T, et al: Design of a centrifugal blood pump with magnetic suspension. Artif Organs 19: 625-630, 1995.
    • (1995) Artif Organs , vol.19 , pp. 625-630
    • Yamane, T.1    Ikeda, T.2    Orita, T.3
  • 13
    • 0029142494 scopus 로고
    • Recent studies of the centrifugal blood pump with a magnetically suspended impeller
    • Akamatsu T, Tsukiya T, Nishimura K, et al: Recent studies of the centrifugal blood pump with a magnetically suspended impeller. Artif Organs 19: 631-634, 1995.
    • (1995) Artif Organs , vol.19 , pp. 631-634
    • Akamatsu, T.1    Tsukiya, T.2    Nishimura, K.3
  • 14
    • 0029146303 scopus 로고
    • An implantable seal-less centrifugal pump with integrated double-disk motor
    • Schima H, Schmallegger H, Huber L, et al: An implantable seal-less centrifugal pump with integrated double-disk motor. Artif Organs 19: 639-643, 1995.
    • (1995) Artif Organs , vol.19 , pp. 639-643
    • Schima, H.1    Schmallegger, H.2    Huber, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.