메뉴 건너뛰기




Volumn 200, Issue 1-2, 1997, Pages 145-153

Competitive flow injection enzyme immunoassay for steroids using a post-column reaction technique

Author keywords

amperometry; budesonide; cortisol; displacement assay; flow injection immunoassay; fluorescence

Indexed keywords

BUDESONIDE; HYDROCORTISONE; PROTEIN G;

EID: 0342618530     PISSN: 00221759     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0022-1759(96)00199-8     Document Type: Article
Times cited : (23)

References (17)
  • 2
    • 0018100061 scopus 로고
    • Thermometric enzyme linked immunosorbent assay in continuous flow system: Optimization and evaluation using human serum albumin as a model system
    • Borrebaeck, C., Börjesson, J. and Mattiasson, B. (1978) Thermometric enzyme linked immunosorbent assay in continuous flow system: optimization and evaluation using human serum albumin as a model system. Clin. Chim. Acta 86, 267.
    • (1978) Clin. Chim. Acta , vol.86 , pp. 267
    • Borrebaeck, C.1    Börjesson, J.2    Mattiasson, B.3
  • 3
    • 0019883215 scopus 로고
    • Synthesis of mono- and dinucleotide photoaffinity probes of ribonucleic acid polymerase
    • De Riemer, L.H. and Meares, C.F. (1981) Synthesis of mono- and dinucleotide photoaffinity probes of ribonucleic acid polymerase. Biochemistry 20, 1606.
    • (1981) Biochemistry , vol.20 , pp. 1606
    • De Riemer, L.H.1    Meares, C.F.2
  • 4
    • 0026734019 scopus 로고
    • Automated bioanalysis of drugs using coupled column liquid chromatography for sample pretreatment. Aspects of quality assurance and collaborative automated handling of data
    • Edholm, L.-E., Blomgren, A., Roos, C. and Ögren, L. (1992) Automated bioanalysis of drugs using coupled column liquid chromatography for sample pretreatment. Aspects of quality assurance and collaborative automated handling of data. Chemometrics and intelligent laboratory systems, Lab. Inf. Manage. 53, 233.
    • (1992) Chemometrics and Intelligent Laboratory Systems, Lab. Inf. Manage , vol.53 , pp. 233
    • Edholm, L.-E.1    Blomgren, A.2    Roos, C.3    Ögren, L.4
  • 5
    • 0002944256 scopus 로고
    • Current concepts and future developments
    • W.P. Collins (Ed.), Wiley, Chichester
    • Ekins, R.P. (1985) Current concepts and future developments. In: W.P. Collins (Ed.), Alternative Immunoassay. Wiley, Chichester, p. 219
    • (1985) Alternative Immunoassay , pp. 219
    • Ekins, R.P.1
  • 6
    • 0347156482 scopus 로고
    • Reaction detector with three dimensional coiled open tubes in HPLC
    • Engelhardt, H. and Neue, U.D. (1982) Reaction detector with three dimensional coiled open tubes in HPLC. Chromatographia 15, 403.
    • (1982) Chromatographia , vol.15 , pp. 403
    • Engelhardt, H.1    Neue, U.D.2
  • 7
    • 0027617019 scopus 로고
    • Theory of a sequential addition competitive binding immunoassay based on high-performance immunoaffinity chromatography
    • Hage, D.S., Thomas, D.H. and Beck, M.S. (1993) Theory of a sequential addition competitive binding immunoassay based on high-performance immunoaffinity chromatography. Anal. Chem. 65 and 1622.
    • (1993) Anal. Chem. , vol.65-1622
    • Hage, D.S.1    Thomas, D.H.2    Beck, M.S.3
  • 8
    • 0024436596 scopus 로고
    • Dual-column immunoassays using protein G affinity chromatography
    • Janis, L.J. and Regnier, F.E. (1989) Dual-column immunoassays using protein G affinity chromatography. Anal. Chem. 61, 1901.
    • (1989) Anal. Chem. , vol.61 , pp. 1901
    • Janis, L.J.1    Regnier, F.E.2
  • 9
    • 0027213061 scopus 로고
    • Determination of drugs in biosamples at picomolar concentrations using competitive ELISA with electrochemical detection: Application to steroids
    • Kronkvist, K., Lövgren, U., Edholm, L.-E. and Johansson, G. (1993) Determination of drugs in biosamples at picomolar concentrations using competitive ELISA with electrochemical detection: application to steroids. J. Pharm. Biomed. Anal. 11, 459.
    • (1993) J. Pharm. Biomed. Anal. , vol.11 , pp. 459
    • Kronkvist, K.1    Lövgren, U.2    Edholm, L.-E.3    Johansson, G.4
  • 11
    • 0009658432 scopus 로고
    • Enzyme-linked flow-injection immunoassay using immobilized secondary antibodies
    • Lee, I.H. and Meyerhoff, M.E. (1988) Enzyme-linked flow-injection immunoassay using immobilized secondary antibodies. Mikrochim. Acta 3, 207.
    • (1988) Mikrochim. Acta , vol.3 , pp. 207
    • Lee, I.H.1    Meyerhoff, M.E.2
  • 12
    • 0028218078 scopus 로고
    • Enzyme amplified immunoassay for steroids in biosamples at low picomolar concentrations
    • Lövgren, U., Kronkvist, K., Johansson, G. and Edholm, L.-E. (1994) enzyme amplified immunoassay for steroids in biosamples at low picomolar concentrations. Anal. Chim. Acta 288, 227.
    • (1994) Anal. Chim. Acta , vol.288 , pp. 227
    • Lövgren, U.1    Kronkvist, K.2    Johansson, G.3    Edholm, L.-E.4
  • 13
    • 0028865033 scopus 로고
    • Biocompatible sample pretreatment for immunochemical techniques using micellar liquid chromatography for separation of corticosteroids
    • Lövgren, U., Johansson, M., Kronkvist, K. and Edholm, L.-E. (1995) Biocompatible sample pretreatment for immunochemical techniques using micellar liquid chromatography for separation of corticosteroids. J. Chromatogr. B 672, 33.
    • (1995) J. Chromatogr. B , vol.672 , pp. 33
    • Lövgren, U.1    Johansson, M.2    Kronkvist, K.3    Edholm, L.-E.4
  • 14
    • 0002844282 scopus 로고
    • Flow injection immunoassay for theophylline using a protein A immunoreactor
    • Palmer, D.A., Edmonds, T.E. and Seare, N.J. (1992) Flow injection immunoassay for theophylline using a protein A immunoreactor. Anal. Proc. 29, 98.
    • (1992) Anal. Proc. , vol.29 , pp. 98
    • Palmer, D.A.1    Edmonds, T.E.2    Seare, N.J.3
  • 15
    • 0026427240 scopus 로고
    • Perfusion chromatography
    • Regnier, F.E. (1991) Perfusion Chromatography. Nature 350, 634.
    • (1991) Nature , vol.350 , pp. 634
    • Regnier, F.E.1
  • 16
    • 0020641647 scopus 로고
    • Kinetic and equilibrium studies of insulin immunoaffinity chromatography
    • Sportsman, J.R., Liddil, J.D. and Wilson, G.S. (1983) Kinetic and equilibrium studies of insulin immunoaffinity chromatography. Anal. Chem. 55, 771.
    • (1983) Anal. Chem. , vol.55 , pp. 771
    • Sportsman, J.R.1    Liddil, J.D.2    Wilson, G.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.