메뉴 건너뛰기




Volumn 25, Issue 6, 2000, Pages 703-708

Electrical thresholds for biomechanical response in the ankle to direct stimulation of spinal roots L4, L5, and S1: Implications for intraoperative pedicle screw testing

Author keywords

Ankle torque; Contraction force; Electrical stimulation; Electromyography; Lumbar spine; Pedicle screw; Spinal nerve roots

Indexed keywords

ANKLE; ARTICLE; BIOMECHANICS; BONE SCREW; CLINICAL ARTICLE; CONTROLLED STUDY; ELECTROMYOGRAM; ELECTROSTIMULATION; FENESTRATION; HUMAN; INTERVERTEBRAL DISK HERNIA; INTRAOPERATIVE PERIOD; LEG MUSCLE; MUSCLE ACTION POTENTIAL; NERVE ROOT COMPRESSION; PRIORITY JOURNAL; SPINAL ROOT; TORQUE;

EID: 0342313586     PISSN: 03622436     EISSN: None     Source Type: Journal    
DOI: 10.1097/00007632-200003150-00009     Document Type: Article
Times cited : (5)

References (17)
  • 1
    • 0018635554 scopus 로고
    • Microsurgical anatomy of lumbosacral spinal roots
    • d'Avella D, Mingrino S. Microsurgical anatomy of lumbosacral spinal roots. J Neurosurg 1979;51:819-23.
    • (1979) J Neurosurg , vol.51 , pp. 819-823
    • D'Avella, D.1    Mingrino, S.2
  • 2
    • 0028586882 scopus 로고
    • Stimulus-evoked EMG monitoring during transpedicular lumbosacral spine instrumentation
    • Calancie B, Madsen P, Lebwohl N. Stimulus-evoked EMG monitoring during transpedicular lumbosacral spine instrumentation. Spine 1994;24:2780-6.
    • (1994) Spine , vol.24 , pp. 2780-2786
    • Calancie, B.1    Madsen, P.2    Lebwohl, N.3
  • 3
    • 0029986628 scopus 로고    scopus 로고
    • Evoked and spontaneous electromyography to evaluate lumbosacral pedicle screw placement
    • Clements DH, Morledge DE, Martin WH, Betz RR. Evoked and spontaneous electromyography to evaluate lumbosacral pedicle screw placement. Spine 1996;21:600-4.
    • (1996) Spine , vol.21 , pp. 600-604
    • Clements, D.H.1    Morledge, D.E.2    Martin, W.H.3    Betz, R.R.4
  • 4
    • 0031410018 scopus 로고    scopus 로고
    • Continuous electromyographic monitoring to detect nerve root injury during thoracolumbar scoliosis surgery
    • Holland NR, Kostuik JP. Continuous electromyographic monitoring to detect nerve root injury during thoracolumbar scoliosis surgery. Spine 1997;22: 2547-50.
    • (1997) Spine , vol.22 , pp. 2547-2550
    • Holland, N.R.1    Kostuik, J.P.2
  • 5
    • 0032518249 scopus 로고    scopus 로고
    • Higher electrical stimulus intensities are required to activate chronically compressed nerve roots: Implications for intraoperative electromyographic pedicle screw testing
    • Holland NR, Lukaczyk TA, Riley LH, Kostuik JP. Higher electrical stimulus intensities are required to activate chronically compressed nerve roots: Implications for intraoperative electromyographic pedicle screw testing. Spine 1998;23: 224-7.
    • (1998) Spine , vol.23 , pp. 224-227
    • Holland, N.R.1    Lukaczyk, T.A.2    Riley, L.H.3    Kostuik, J.P.4
  • 6
    • 0029093114 scopus 로고
    • Triggered electromyographic threshold for accuracy of pedicle screw placement
    • Lenke LG, Padberg AM, Russo MH, Bridwell KH, Gelb DE. Triggered electromyographic threshold for accuracy of pedicle screw placement. Spine 1995; 20:1585-91.
    • (1995) Spine , vol.20 , pp. 1585-1591
    • Lenke, L.G.1    Padberg, A.M.2    Russo, M.H.3    Bridwell, K.H.4    Gelb, D.E.5
  • 7
    • 0026752648 scopus 로고
    • Determination of the segmental sensory and motor innervation of the lumbosacral spinal nerves: An electrophysiological study
    • Liguori R, Krarup C, Trojaborg W. Determination of the segmental sensory and motor innervation of the lumbosacral spinal nerves: An electrophysiological study. Brain 1992;115:915-34.
    • (1992) Brain , vol.115 , pp. 915-934
    • Liguori, R.1    Krarup, C.2    Trojaborg, W.3
  • 8
    • 0028957058 scopus 로고
    • Evaluation of intrapedicular screw position using intraoperative evoked electromyography
    • Maguire J, Wallace S, Madiga R, Leppanen R, Draper V. Evaluation of intrapedicular screw position using intraoperative evoked electromyography. Spine 1995;20:1068-74.
    • (1995) Spine , vol.20 , pp. 1068-1074
    • Maguire, J.1    Wallace, S.2    Madiga, R.3    Leppanen, R.4    Draper, V.5
  • 9
    • 0031410020 scopus 로고    scopus 로고
    • Clinical and electrophysiologic characteristics of compressed lumbar nerve roots
    • Matsui H, Kanamori M, Kawaguchi Y, Kitagawa H, Nakamura H, Tsuji H. Clinical and electrophysiologic characteristics of compressed lumbar nerve roots. Spine 1997;22:2100-5.
    • (1997) Spine , vol.22 , pp. 2100-2105
    • Matsui, H.1    Kanamori, M.2    Kawaguchi, Y.3    Kitagawa, H.4    Nakamura, H.5    Tsuji, H.6
  • 10
    • 0019203648 scopus 로고
    • Variations of the lumbosacral myotomes with bony segmental anomalies
    • McCullogh JA, Waddell G. Variations of the lumbosacral myotomes with bony segmental anomalies. J Bone Joint Surg [Br] 1980;62:475-80.
    • (1980) J Bone Joint Surg [Br] , vol.62 , pp. 475-480
    • McCullogh, J.A.1    Waddell, G.2
  • 12
    • 0025888401 scopus 로고
    • Electrophysiologic mapping of the segmental anatomy of the muscles of the lower extremity
    • Phillips LH, Park TS. Electrophysiologic mapping of the segmental anatomy of the muscles of the lower extremity. Muscle Nerve 1991;14:1213-8.
    • (1991) Muscle Nerve , vol.14 , pp. 1213-1218
    • Phillips, L.H.1    Park, T.S.2
  • 13
    • 0031045592 scopus 로고    scopus 로고
    • Persistently electrified pedicle stimulation instruments in spinal instrumentation: Technique and protocol development
    • Rose RD, Welch WC, Balzer JR, Jacobs GB. Persistently electrified pedicle stimulation instruments in spinal instrumentation: Technique and protocol development. Spine 1997;22:334-43.
    • (1997) Spine , vol.22 , pp. 334-343
    • Rose, R.D.1    Welch, W.C.2    Balzer, J.R.3    Jacobs, G.B.4
  • 14
    • 0026928495 scopus 로고
    • Multielectrode spiral cuff for selective stimulation of nerve fibres
    • Rozman J, Trlep M. Multielectrode spiral cuff for selective stimulation of nerve fibres. J Med Eng Tech 1992;16:194-203.
    • (1992) J Med Eng Tech , vol.16 , pp. 194-203
    • Rozman, J.1    Trlep, M.2
  • 15
    • 0021086103 scopus 로고
    • Anatomy and significance of fixation of the lumbosacral nerve roots in sciatica
    • Spencer DL, Irwin GS, Miller JAA. Anatomy and significance of fixation of the lumbosacral nerve roots in sciatica. Spine 1983;8:672-9.
    • (1983) Spine , vol.8 , pp. 672-679
    • Spencer, D.L.1    Irwin, G.S.2    Miller, J.A.A.3
  • 16
    • 0001396183 scopus 로고
    • The myotomes L2-S2 in man
    • Thage O. The myotomes L2-S2 in man. Acta Neurol Scand 1965; 41(Suppl 13):241-3.
    • (1965) Acta Neurol Scand , vol.41 , Issue.13 SUPPL. , pp. 241-243
    • Thage, O.1
  • 17
    • 0017909052 scopus 로고
    • Functional electrical stimulation of extremities: Its basis, technology and role in rehabilitation
    • Trnkoczy A. Functional electrical stimulation of extremities: Its basis, technology and role in rehabilitation. Automedica 1978;2:59-100.
    • (1978) Automedica , vol.2 , pp. 59-100
    • Trnkoczy, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.