Volumn 22, Issue 2, 1997, Pages 121-125

Lateral scatter correction algorithm for percentage depth dose in a large-field photon beam

Author keywords

Dosimetry; Large field; Lateral scatter correction; TBI

Indexed keywords

ALGORITHM; ARTICLE; NONHUMAN; PHANTOM; PHOTON; PRIORITY JOURNAL; RADIATION DOSE; RADIATION FIELD; RADIATION SCATTERING; WHOLE BODY RADIATION;

EID: 0342275261     PISSN: 09583947     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0958-3947(97)00004-6     Document Type: Article
Times cited : (4)

References (14)
  • 1
    • 0003511488 scopus 로고
    • The physical aspects of total and half body photon irradiation
    • Task Group 29 of the Radiation Therapy Committee of the American Association of Physicists in Medicine
    • Van Dyk, J.; Galvin, J, M.; Glasgow, G.P.; Podgorsak, E.B. The physical aspects of total and half body photon irradiation. AAPM Report 17. Task Group 29 of the Radiation Therapy Committee of the American Association of Physicists in Medicine, 1989.
    • (1989) AAPM Report 17.
    • Van Dyk, J.1    Galvin, J.M.2    Glasgow, G.P.3    Podgorsak, E.B.4
  • 2
    • 0023188967 scopus 로고
    • Total body irradiation - Review of treatment techniques in europe
    • Quast, U. Total body irradiation - review of treatment techniques in Europe. Rad. Oncol. 9:91-106; 1987.
    • (1987) Rad. Oncol. , vol.9 , pp. 91-106
    • Quast, U.1
  • 4
    • 0028121015 scopus 로고
    • A translating-bed technique for total body irradiation
    • Gerig, L.H.; Szanto, J.; Bichay, T.; Genest, P. A translating-bed technique for total body irradiation. Phys. Med. Biol. 39:19-35; 1994.
    • (1994) Phys. Med. Biol. , vol.39 , pp. 19-35
    • Gerig, L.H.1    Szanto, J.2    Bichay, T.3    Genest, P.4
  • 6
    • 0023219204 scopus 로고
    • Dosimetry for total body irradiation
    • Van Dyk, J. Dosimetry for total body irradiation. Rad. Oncol. 9:107-118; 1987.
    • (1987) Rad. Oncol. , vol.9 , pp. 107-118
    • Van Dyk, J.1
  • 8
    • 0021016929 scopus 로고
    • Calculation and prescription of dose for total body irradiation
    • Galvin, J.M. Calculation and prescription of dose for total body irradiation. Int. J. Radiat. Oncol. Biol. Phys. 9:1919-1924; 1983.
    • (1983) Int. J. Radiat. Oncol. Biol. Phys. , vol.9 , pp. 1919-1924
    • Galvin, J.M.1
  • 9
    • 0021851522 scopus 로고
    • Physical treatment planning of total body irradiation: Patient translation and beam-zone method
    • Quast, U. Physical treatment planning of total body irradiation: patient translation and beam-zone method. Med. Phys. 12:567-574; 1985.
    • (1985) Med. Phys. , vol.12 , pp. 567-574
    • Quast, U.1
  • 10
    • 0021872440 scopus 로고
    • The influence of phantom size on output, peak scatter factor, and percentage depth dose in large-field photon irradiation
    • Podgorsak, E.B.; Pla, C.; Evans, M.D.C.; Pla, M. The influence of phantom size on output, peak scatter factor, and percentage depth dose in large-field photon irradiation. Med. Phys. 12:639-645; 1985.
    • (1985) Med. Phys. , vol.12 , pp. 639-645
    • Podgorsak, E.B.1    Pla, C.2    Evans, M.D.C.3    Pla, M.4
  • 14
    • 0031047465 scopus 로고    scopus 로고
    • A CT-aided PC-based physical treatment planning of TBI: A method for dose calculation
    • Sánchez-Nieto, B.; Sánchez-Doblado, F.; Terrón, J.A. A CT-aided PC-based physical treatment planning of TBI: a method for dose calculation. Radiother. Oncol.; 42:77-85, 1997.
    • (1997) Radiother. Oncol. , vol.42 , pp. 77-85
    • Sánchez-Nieto, B.1    Sánchez-Doblado, F.2    Terrón, J.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.