메뉴 건너뛰기




Volumn 44, Issue 8, 2003, Pages 968-978

Evaluation of remedial alternatives for a petroleum contaminated unconfined aquifer with fluctuating groundwater level

Author keywords

Air sparging; Bioventing; Korea; Petroleum; Pump and treat; Remedial alternatives

Indexed keywords

CONTAMINATION; CRUDE PETROLEUM; GROUNDWATER; HYDROGEOLOGY; LEAKAGE (FLUID); RISK ASSESSMENT; SOILS; TOLUENE;

EID: 0242709440     PISSN: 09430105     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00254-003-0840-z     Document Type: Article
Times cited : (4)

References (17)
  • 1
    • 85007174968 scopus 로고
    • Standard guide for risk-based corrective action applied at petroleum release sites. E1739-95
    • Philadelphia
    • ASTM (1995) Standard guide for risk-based corrective action applied at petroleum release sites. E1739-95, Annual Book of ASTM Standards, Philadelphia
    • (1995) Annual Book of ASTM Standards
  • 5
    • 0035395128 scopus 로고    scopus 로고
    • Attenuation of petroleum hydrocarbons in smear zones: A case study
    • Lee CH, Lee JY, Cheon JY, Lee KK (2001a) Attenuation of petroleum hydrocarbons in smear zones: a case study. J Environ Eng 127:639-647
    • (2001) J Environ Eng , vol.127 , pp. 639-647
    • Lee, C.H.1    Lee, J.Y.2    Cheon, J.Y.3    Lee, K.K.4
  • 6
    • 0034820351 scopus 로고    scopus 로고
    • Statistical evaluation of geochemical parameters distribution in a ground water system contaminated with petroleum hydrocarbons
    • Lee JY, Cheon JY, Lee KK, Lee SY, Lee MH (2001b) Statistical evaluation of geochemical parameters distribution in a ground water system contaminated with petroleum hydrocarbons. J Environ Qual 35:1548-1563
    • (2001) J Environ Qual , vol.35 , pp. 1548-1563
    • Lee, J.Y.1    Cheon, J.Y.2    Lee, K.K.3    Lee, S.Y.4    Lee, M.H.5
  • 7
    • 0034980526 scopus 로고    scopus 로고
    • Factors affecting the distribution of hydrocarbon contaminants and hydrogeochemical parameters in a shallow sand aquifer
    • Lee JY, Cheon JY, Lee KK, Lee SY, Lee MH (2001c) Factors affecting the distribution of hydrocarbon contaminants and hydrogeochemical parameters in a shallow sand aquifer. J Cont Hydrol 50:139-158
    • (2001) J Cont Hydrol , vol.50 , pp. 139-158
    • Lee, J.Y.1    Cheon, J.Y.2    Lee, K.K.3    Lee, S.Y.4    Lee, M.H.5
  • 8
    • 0034853105 scopus 로고    scopus 로고
    • Soil vapor extraction and bioventing pilot tests in a petroleum contaminated site in Korea
    • Lee JY, Lee CH, Lee KK, Choi SI (2001d) Soil vapor extraction and bioventing pilot tests in a petroleum contaminated site in Korea. Soil Sediment Cont 10: 439-458
    • (2001) Soil Sediment Cont , vol.10 , pp. 439-458
    • Lee, J.Y.1    Lee, C.H.2    Lee, K.K.3    Choi, S.I.4
  • 9
    • 0036504723 scopus 로고    scopus 로고
    • Evaluation of air injection and extraction tests in a petroleum contaminated site, Korea
    • Lee CH, Lee JY, Jang WY, Jeon YH, Lee KK (2002) Evaluation of air injection and extraction tests in a petroleum contaminated site, Korea. Water Air Soil Pollut 135:65-91
    • (2002) Water Air Soil Pollut , vol.135 , pp. 65-91
    • Lee, C.H.1    Lee, J.Y.2    Jang, W.Y.3    Jeon, Y.H.4    Lee, K.K.5
  • 10
    • 0030150261 scopus 로고    scopus 로고
    • LNAPL thickness in monitoring wells considering hysteresis and entrapmemt
    • Marinelli F, Durnford DS (1996) LNAPL thickness in monitoring wells considering hysteresis and entrapmemt. Ground Water 34:405-414
    • (1996) Ground Water , vol.34 , pp. 405-414
    • Marinelli, F.1    Durnford, D.S.2
  • 12
    • 0242614531 scopus 로고
    • Guidance on remedial actions for contaminated ground water at Superfund sites EPA/540/G-99/003, OSWER Directive 9283.1-2, US EPA, Washington, DC
    • USEPA (Environmental Protection Agency) (1988) Guidance on remedial actions for contaminated ground water at Superfund sites. EPA/540/G-99/003, OSWER Directive 9283.1-2, US EPA, Washington, DC
    • (1988)
  • 13
    • 0242529886 scopus 로고
    • Risk assessment guidance for Superfund. EPA/540/1-89/002, OSWER, US EPA, Washington, DC
    • USEPA (Environmental Protection Agency) (1989) Risk assessment guidance for Superfund. EPA/540/1-89/002, OSWER, US EPA, Washington, DC
    • (1989)
  • 14
    • 0242614533 scopus 로고
    • Bioventing principles and practice. EPA/540/R-95/534a, OSWER, US EPA, Washington, DC
    • USEPA (Environmental Protection Agency) (1995) Bioventing principles and practice. EPA/540/R-95/534a, OSWER, US EPA, Washington, DC
    • (1995)
  • 15
    • 0242614532 scopus 로고    scopus 로고
    • Design guidelines for conventional pump-and-treat systems. EPA/540/ S-97/504, OSWER, US EPA, Washington, DC
    • USEPA (Environmental Protection Agency) (1997) Design guidelines for conventional pump-and-treat systems. EPA/540/ S-97/504, OSWER, US EPA, Washington, DC
    • (1997)
  • 17
    • 84987553238 scopus 로고
    • Reply to discussion of analysis of ground-water remedial alternatives at a Superfund site
    • Zheng C, Bennett GD, Andrews CB (1992) Reply to discussion of analysis of ground-water remedial alternatives at a Superfund site. Ground Water 30:440-442
    • (1992) Ground Water , vol.30 , pp. 440-442
    • Zheng, C.1    Bennett, G.D.2    Andrews, C.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.