메뉴 건너뛰기




Volumn 27, Issue 16, 2003, Pages 53-57+86

Research on the voltage unbalance of DC capacitors of cascade STATCOM. Part one: Simulations and experiments

Author keywords

Cascade multilevel inverter; DC capacitor voltage unbalance; Simulation; Static synchronous compensator (STATCOM)

Indexed keywords

CAPACITORS; COMPUTER SIMULATION; DC MACHINERY; ELECTRIC POTENTIAL;

EID: 0242691207     PISSN: 10001026     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (58)

References (9)
  • 3
    • 0027539936 scopus 로고
    • Development of a large static VAR generator using self-commutated inverters for improving power system stability
    • Mori S, Matsuno K, Hasgawa T, et al. Development of a Large Static VAR Generator Using Self-commutated Inverters for improving Power System Stability. IEEE Trans on Power Systems, 1993, 8(1): 371-377
    • (1993) IEEE Trans. on Power Systems , vol.8 , Issue.1 , pp. 371-377
    • Mori, S.1    Matsuno, K.2    Hasgawa, T.3
  • 5
    • 0029345988 scopus 로고    scopus 로고
    • Development of a 100 Mvar static condenser for voltage control of transmission systems
    • Schauder C, Gernhardt M, Stacey E, et al. Development of a 100 Mvar Static Condenser for Voltage Control of Transmission Systems. IEEE Trans on Power Delivery, 1996, 10(3): 1486-1496
    • (1996) IEEE Trans. on Power Delivery , vol.10 , Issue.3 , pp. 1486-1496
    • Schauder, C.1    Gernhardt, M.2    Stacey, E.3
  • 6
    • 0032187658 scopus 로고    scopus 로고
    • AEP UPFC project, installation, commissioning and operation of the 160 Mvar STATCOM (Phase I)
    • Schauder C, Stacey E, Lund M, et al. AEP UPFC Project, Installation, Commissioning and Operation of the 160 Mvar STATCOM (Phase I). IEEE Trans on Power Delivery, 1998, 13(4): 1530-1535
    • (1998) IEEE Trans. on Power Delivery , vol.13 , Issue.4 , pp. 1530-1535
    • Schauder, C.1    Stacey, E.2    Lund, M.3
  • 7
    • 0039259230 scopus 로고    scopus 로고
    • Development of ±20 Mvar STATCOM employing GTO inverters
    • Liu Wenhua, Liang Xu, Jiang Qirong, et al. Development of ±20 Mvar STATCOM Employing GTO Inverters. Automation of Electric Power Systems, 2000, 24(23): 19-23
    • (2000) Automation of Electric Power Systems , vol.24 , Issue.23 , pp. 19-23
    • Liu, W.1    Liang, X.2    Jiang, Q.3
  • 8
    • 0031140759 scopus 로고    scopus 로고
    • Dynamic performance and control of a static VAR generator using cascade multilevel inverters
    • Peng F Z, Lai J S. Dynamic Performance and Control of a Static VAR Generator Using Cascade Multilevel Inverters. IEEE Trans on Industry Applications, 1997, 33(3): 748-755
    • (1997) IEEE Trans. on Industry Applications , vol.33 , Issue.3 , pp. 748-755
    • Peng, F.Z.1    Lai, J.S.2
  • 9
    • 0036087946 scopus 로고    scopus 로고
    • A STATCOM-based relocatable SVC project in the UK for national grid
    • New York: IEEE
    • Hanson D J, Horwill C, Gemmell B D, et al. A STATCOM-based Relocatable SVC Project in the UK for National Grid. In: Power Engineering Society Winter Meeting, 2002, Vol 1. New York: IEEE, 2002. 532-537
    • (2002) Power Engineering Society Winter Meeting , vol.1 , pp. 532-537
    • Hanson, D.J.1    Horwill, C.2    Gemmell, B.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.