메뉴 건너뛰기




Volumn 85, Issue SUPPL. 4, 2003, Pages 111-114

Effects of walking gait on ultra-high molecular weight polyethylene damage in unicompartmental knee systems: A finite element study

Author keywords

[No Author keywords available]

Indexed keywords

POLYETHYLENE;

EID: 0242664740     PISSN: 00219355     EISSN: None     Source Type: Journal    
DOI: 10.2106/00004623-200300004-00014     Document Type: Conference Paper
Times cited : (23)

References (10)
  • 1
    • 0031791833 scopus 로고    scopus 로고
    • The Oxford medial unicompartmental arthroplasty: A ten-year survival study
    • Murray DW, Goodfellow JW, O'Connor JJ. The Oxford medial unicompartmental arthroplasty: a ten-year survival study. J Bone Joint Surg Br. 1998;80:983-9.
    • (1998) J Bone Joint Surg Br , vol.80 , pp. 983-989
    • Murray, D.W.1    Goodfellow, J.W.2    O'Connor, J.J.3
  • 4
    • 0028671975 scopus 로고
    • Compressive stress relaxation behavior of irradiated ultra-high molecular weight polyethylene at 37 degrees C
    • Waldman SD, Bryant JT. Compressive stress relaxation behavior of irradiated ultra-high molecular weight polyethylene at 37 degrees C. J Appl Biomater. 1994;5:333-8.
    • (1994) J Appl Biomater , vol.5 , pp. 333-338
    • Waldman, S.D.1    Bryant, J.T.2
  • 6
    • 0037641149 scopus 로고    scopus 로고
    • The effects of articular geometry on delamination and pitting of UHMWPE tibial inserts: A finite element study
    • Morra EA, Postak PD, Greenwald AS. The effects of articular geometry on delamination and pitting of UHMWPE tibial inserts: a finite element study. Orthop Trans. 1996;20:66.
    • (1996) Orthop Trans , vol.20 , pp. 66
    • Morra, E.A.1    Postak, P.D.2    Greenwald, A.S.3
  • 7
    • 0242669446 scopus 로고    scopus 로고
    • The effects of articular geometry on delamination and pitting of UHMWPE tibial inserts II: A finite element study
    • Morra EA, Postak PD, Greenwald AS. The effects of articular geometry on delamination and pitting of UHMWPE tibial inserts II: a finite element study. Orthop Trans. 1997;21:217.
    • (1997) Orthop Trans , vol.21 , pp. 217
    • Morra, E.A.1    Postak, P.D.2    Greenwald, A.S.3
  • 8
    • 0242501037 scopus 로고    scopus 로고
    • The influence of mobile bearing knee geometry on the wear of UHMWPE tibial inserts: A finite element study
    • Mar 15-19; Orlando, FL
    • Morra EA, Postak PD, Greenwald AS. The influence of mobile bearing knee geometry on the wear of UHMWPE tibial inserts: a finite element study. Read at the Annual Meeting of the American Academy of Orthopaedic Surgeons; 2000 Mar 15-19; Orlando, FL. p 617.
    • (2000) Annual Meeting of the American Academy of Orthopaedic Surgeons , pp. 617
    • Morra, E.A.1    Postak, P.D.2    Greenwald, A.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.