메뉴 건너뛰기




Volumn 48, Issue 6, 2003, Pages 1269-1274

A New Method for Collection and Identification of Gunshot Residues from the Hands of Shooters

Author keywords

Antimony; Barium; Collection; Forensic science; Gunshot residues; Inductively coupled plasma mass spectrometry; Lead

Indexed keywords

ANTIMONY; BARIUM; EDETIC ACID; GUNPOWDER; LEAD; NITRIC ACID; WATER;

EID: 0242610969     PISSN: 00221198     EISSN: None     Source Type: Journal    
DOI: 10.1520/jfs2002441     Document Type: Article
Times cited : (30)

References (29)
  • 1
    • 0030793488 scopus 로고    scopus 로고
    • Gunshot residue analysis - A review
    • Meng HH, Caddy B. Gunshot residue analysis-a review. J Forensic Sci 1997;42(4):553-70.
    • (1997) J Forensic Sci , vol.42 , Issue.4 , pp. 553-570
    • Meng, H.H.1    Caddy, B.2
  • 2
    • 0035876938 scopus 로고    scopus 로고
    • Identification of gunshot residue: A critic review
    • Romolo FS, Margot P. Identification of gunshot residue: a critic review. Forensic Sci Int 2001;119:195-211.
    • (2001) Forensic Sci Int , vol.119 , pp. 195-211
    • Romolo, F.S.1    Margot, P.2
  • 4
    • 0020044187 scopus 로고
    • Formation of gunshot residues
    • Basu S. Formation of gunshot residues. J Forensic Sci 1982;27(1):72-91.
    • (1982) J Forensic Sci , vol.27 , Issue.1 , pp. 72-91
    • Basu, S.1
  • 5
    • 0029931924 scopus 로고    scopus 로고
    • A survey of gunshot residue analysis methods
    • Singer RL, Davis D, Houck MM. A survey of gunshot residue analysis methods. J Forensic Sci 1996;41(2):195-8.
    • (1996) J Forensic Sci , vol.41 , Issue.2 , pp. 195-198
    • Singer, R.L.1    Davis, D.2    Houck, M.M.3
  • 6
    • 0025045729 scopus 로고
    • Survey of gunshot residue analysis in forensic science laboratories
    • DeGaetano D, Siegel JA. Survey of gunshot residue analysis in forensic science laboratories. J Forensic Sci 1990;35(5):1087-95.
    • (1990) J Forensic Sci , vol.35 , Issue.5 , pp. 1087-1095
    • DeGaetano, D.1    Siegel, J.A.2
  • 7
    • 0023194954 scopus 로고
    • Analysis of gunshot primer residue collection swabs using flameless atomic absorption spectrophotometry: A reexamination of extraction and instrument procedures
    • Koons RD, Havekost DG, Peters CA. Analysis of gunshot primer residue collection swabs using flameless atomic absorption spectrophotometry: a reexamination of extraction and instrument procedures. J Forensic Sci 1987;32(4):846-65.
    • (1987) J Forensic Sci , vol.32 , Issue.4 , pp. 846-865
    • Koons, R.D.1    Havekost, D.G.2    Peters, C.A.3
  • 8
    • 0015050521 scopus 로고
    • Rapid detection of firearms discharge residues by atomic absorption and neutron activation analysis
    • Krishnan SS. Rapid detection of firearms discharge residues by atomic absorption and neutron activation analysis. J Forensic Sci 1971;16:144-51.
    • (1971) J Forensic Sci , vol.16 , pp. 144-151
    • Krishnan, S.S.1
  • 9
    • 0019503335 scopus 로고
    • Rapid determination of antimony, barium, and lead in gunshot residue via automated atomic absorption spectrophotometry
    • Newton JT. Rapid determination of antimony, barium, and lead in gunshot residue via automated atomic absorption spectrophotometry. J Forensic Sci 1981;26:302-12.
    • (1981) J Forensic Sci , vol.26 , pp. 302-312
    • Newton, J.T.1
  • 10
    • 0023837185 scopus 로고    scopus 로고
    • Determination of barium in gunshot residue collection swabs using inductively coupled plasma-atomic emission spectrometry
    • Koons RD, Havekost DG, Peters CA. Determination of barium in gunshot residue collection swabs using inductively coupled plasma-atomic emission spectrometry. J Forensic Sci 1988;33(1):3541.
    • (1988) J Forensic Sci , vol.33 , Issue.1 , pp. 3541
    • Koons, R.D.1    Havekost, D.G.2    Peters, C.A.3
  • 12
    • 0023153512 scopus 로고
    • Automated gunshot residue particle search and characterization
    • Tillman WL. Automated gunshot residue particle search and characterization. J Forensic Sci 1987;32(1):62-7.
    • (1987) J Forensic Sci , vol.32 , Issue.1 , pp. 62-67
    • Tillman, W.L.1
  • 13
    • 0028789778 scopus 로고
    • Casework experience of GSR detection in Israel, on samples from hands, hair, and clothing using an autosearch SEM/EDX system
    • Zeichner A, Levin N. Casework experience of GSR detection in Israel, on samples from hands, hair, and clothing using an autosearch SEM/EDX system. J Forensic Sci 1995;40(6):1082-5.
    • (1995) J Forensic Sci , vol.40 , Issue.6 , pp. 1082-1085
    • Zeichner, A.1    Levin, N.2
  • 14
    • 0025755821 scopus 로고
    • Evaluation of instrumental parameters for automated scanning electron microscopy/gunshot residue particle analysis
    • Germani M. Evaluation of instrumental parameters for automated scanning electron microscopy/gunshot residue particle analysis. J Forensic Sci 1991;36(2):331-42.
    • (1991) J Forensic Sci , vol.36 , Issue.2 , pp. 331-342
    • Germani, M.1
  • 15
    • 0025800388 scopus 로고
    • Gunshot residue particles formed by using different types of ammunition in the same firearm
    • Zeichner A, Levin N, Springer E. Gunshot residue particles formed by using different types of ammunition in the same firearm. J Forensic Sci 1991;36(4):1020-6.
    • (1991) J Forensic Sci , vol.36 , Issue.4 , pp. 1020-1026
    • Zeichner, A.1    Levin, N.2    Springer, E.3
  • 16
    • 0023837185 scopus 로고    scopus 로고
    • Determination of barium in gunshot residue collection swabs using inductively coupled plasma-atomic emission spectrometry
    • Koons RD, Havekost DG, Peters CA. Determination of barium in gunshot residue collection swabs using inductively coupled plasma-atomic emission spectrometry. J Forensic Sci 1998;33(1):35-41.
    • (1998) J Forensic Sci , vol.33 , Issue.1 , pp. 35-41
    • Koons, R.D.1    Havekost, D.G.2    Peters, C.A.3
  • 17
    • 0004369301 scopus 로고
    • Inductively coupled plasma-mass spectrometry, spectrochim
    • Date AR. Inductively coupled plasma-mass spectrometry, spectrochim. Acta Rev 1991;14(1/2):3-32.
    • (1991) Acta Rev , vol.14 , Issue.1-2 , pp. 3-32
    • Date, A.R.1
  • 19
    • 0031902526 scopus 로고    scopus 로고
    • Analysis of gunshot primer residue collection swabs by inductively coupled plasma-mass spectrometry
    • Koons RD. Analysis of gunshot primer residue collection swabs by inductively coupled plasma-mass spectrometry. J Forensic Sci 1998;43(4):748-54.
    • (1998) J Forensic Sci , vol.43 , Issue.4 , pp. 748-754
    • Koons, R.D.1
  • 20
    • 0027235595 scopus 로고
    • Collection efficiency of gunshot (GSR) particles from hair and hands using double-side adhesive tape
    • Zeichner A, Levin N. Collection efficiency of gunshot (GSR) particles from hair and hands using double-side adhesive tape. J Forensic Sci 1993;38(3):571-84.
    • (1993) J Forensic Sci , vol.38 , Issue.3 , pp. 571-584
    • Zeichner, A.1    Levin, N.2
  • 21
    • 0029911047 scopus 로고    scopus 로고
    • An update on the use of the sodium rhodizonate test for the detection of lead originating from firearm discharges
    • Bartsch MR, Kobus HJ, Wainwright KP. An update on the use of the sodium rhodizonate test for the detection of lead originating from firearm discharges. J Forensic Sci 1996;41(6):1046-51.
    • (1996) J Forensic Sci , vol.41 , Issue.6 , pp. 1046-1051
    • Bartsch, M.R.1    Kobus, H.J.2    Wainwright, K.P.3
  • 24
    • 0000273877 scopus 로고    scopus 로고
    • Determination of antimony species with high-performance liquid chromatography using element specific detection
    • Lintschinger J, Koch I, Serves S, Feldmann J, Cullen WR. Determination of antimony species with high-performance liquid chromatography using element specific detection. Fresenius J Anal Chem 1997;359:484-91.
    • (1997) Fresenius J Anal Chem , vol.359 , pp. 484-491
    • Lintschinger, J.1    Koch, I.2    Serves, S.3    Feldmann, J.4    Cullen, W.R.5
  • 25
    • 0034575978 scopus 로고    scopus 로고
    • Extraction of antimony and arsenic from freshdried plant samples as determined by HG-AAS
    • Krachler M, Emons H. Extraction of antimony and arsenic from freshdried plant samples as determined by HG-AAS. Fresenius J Anal Chem 2000;368:702-7.
    • (2000) Fresenius J Anal Chem , vol.368 , pp. 702-707
    • Krachler, M.1    Emons, H.2
  • 26
    • 0028496738 scopus 로고
    • Performance characteristic of inductively coupled plasma mass spectrometry with high mass resolution
    • Feldmann I, Tittes W, Jakubowsky N, Stuewer D. Performance characteristic of inductively coupled plasma mass spectrometry with high mass resolution. J Anal At Spec 1994;9:1007-14.
    • (1994) J Anal At Spec , vol.9 , pp. 1007-1014
    • Feldmann, I.1    Tittes, W.2    Jakubowsky, N.3    Stuewer, D.4
  • 27
    • 0025051109 scopus 로고
    • Barium and antimony distribution on the hands of non-shooters
    • Havekost DG, Peters CA, Koons RD. Barium and antimony distribution on the hands of non-shooters. J Forensic Sci 1990;35(5):1096-114.
    • (1990) J Forensic Sci , vol.35 , Issue.5 , pp. 1096-1114
    • Havekost, D.G.1    Peters, C.A.2    Koons, R.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.