메뉴 건너뛰기




Volumn 35, Issue 5, 2003, Pages 246-249

Neuromonitoring in Thyroid Surgery: The View of the Laryngologist

Author keywords

Intraoperative monitoring; Laryngoscopy; Recurrent laryngeal nerve; Thyroidectomy

Indexed keywords

ACCIDENT PREVENTION; CONSERVATIVE TREATMENT; DIAGNOSTIC VALUE; DOCUMENTATION; ELECTROMYOGRAM; EQUIPMENT; FACIAL NERVE DISEASE; HUMAN; INCIDENCE; LARYNGOLOGIST; NERVE INJURY; NERVE STIMULATION; NEUROMONITORING; NEUROPHYSIOLOGY; PAROTID GLAND; PATIENT MONITORING; PEROPERATIVE CARE; POSTOPERATIVE PERIOD; RECURRENT LARYNGEAL NERVE; RECURRENT LARYNGEAL NERVE PALSY; REVIEW; RISK MANAGEMENT; SENSITIVITY ANALYSIS; SIGNAL DETECTION; STANDARD; SUPERIOR LARYNGEAL NERVE; SURGICAL TECHNIQUE; THYROID SURGERY; THYROIDECTOMY;

EID: 0242544077     PISSN: 16821769     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10353-003-0020-0     Document Type: Review
Times cited : (9)

References (17)
  • 2
    • 0029935617 scopus 로고    scopus 로고
    • Intraoperative electrophysiologic monitoring of recurrent laryngeal nerve
    • Eisele WE: Intraoperative electrophysiologic monitoring of recurrent laryngeal nerve. Laryngoscope 1996;106:443-449.
    • (1996) Laryngoscope , vol.106 , pp. 443-449
    • Eisele, W.E.1
  • 4
    • 0242619399 scopus 로고
    • Electrical stimulation of the human recurrent laryngeal nerve during thyroid operation
    • Flisberg K, Lindholm T: Electrical stimulation of the human recurrent laryngeal nerve during thyroid operation. Acta Otolaryngol 1970;87:330-333.
    • (1970) Acta Otolaryngol , vol.87 , pp. 330-333
    • Flisberg, K.1    Lindholm, T.2
  • 5
    • 0036269764 scopus 로고    scopus 로고
    • A critical estimation of intraoperative neuromonitoring (IONM) in thyroid surgery
    • Hamelmann WH, Meyer T, Timm S, Timmermann W: A critical estimation of intraoperative neuromonitoring (IONM) in thyroid surgery. Zentralbl Chir 2002;127:409-413.
    • (2002) Zentralbl Chir , vol.127 , pp. 409-413
    • Hamelmann, W.H.1    Meyer, T.2    Timm, S.3    Timmermann, W.4
  • 6
    • 0036154775 scopus 로고    scopus 로고
    • Laryngeal recurrent nerve injury in surgery for benign thyroid diseases: Effect of nerve dissection and impact of individual surgeon in more than 27,000 nerves at risk
    • Hermann M, Alk G, Roka R, Glaser K, Freissmuth M: Laryngeal recurrent nerve injury in surgery for benign thyroid diseases: effect of nerve dissection and impact of individual surgeon in more than 27,000 nerves at risk. Ann Surg 2002;235:261-268.
    • (2002) Ann Surg , vol.235 , pp. 261-268
    • Hermann, M.1    Alk, G.2    Roka, R.3    Glaser, K.4    Freissmuth, M.5
  • 7
    • 0021140657 scopus 로고
    • Endolaryngeal devices for perioperative identification and functional testing of the recurrent nerve
    • Hvidegaard T, Vase P, Dalsgaard SC, Jorgensen K: Endolaryngeal devices for perioperative identification and functional testing of the recurrent nerve. Otolaryngol Head Neck Surg 1984;92:292-294.
    • (1984) Otolaryngol Head Neck Surg , vol.92 , pp. 292-294
    • Hvidegaard, T.1    Vase, P.2    Dalsgaard, S.C.3    Jorgensen, K.4
  • 8
    • 0034184801 scopus 로고    scopus 로고
    • Die intraoperative elektromyographische Identifikation des Nervus laryngeus recurrens
    • Jonas J, Bähr R: Die intraoperative elektromyographische Identifikation des Nervus laryngeus recurrens. Chirurg 2000;71:534-538.
    • (2000) Chirurg , vol.71 , pp. 534-538
    • Jonas, J.1    Bähr, R.2
  • 9
    • 0036858442 scopus 로고    scopus 로고
    • Intraoperatives Neuromonitoring der Stimmbandnerven -Risikominderung für Recurrensparesen
    • Neumann HJ: Intraoperatives Neuromonitoring der Stimmbandnerven -Risikominderung für Recurrensparesen. Laryngorhinootologie 2002;81:795-796.
    • (2002) Laryngorhinootologie , vol.81 , pp. 795-796
    • Neumann, H.J.1
  • 10
    • 0025141618 scopus 로고
    • Intraoperative identification of recurrent laryngeal nerve and demonstration of its function
    • Premachandra DJ, Radcliffe GJ, Stearns MP: Intraoperative identification of recurrent laryngeal nerve and demonstration of its function. Laryngoscope 1990;100:94-96.
    • (1990) Laryngoscope , vol.100 , pp. 94-96
    • Premachandra, D.J.1    Radcliffe, G.J.2    Stearns, M.P.3
  • 11
    • 0025887575 scopus 로고
    • Intraoperative recurrent laryngeal nerve monitoring
    • Rice DH, Cone-Wesson B: Intraoperative recurrent laryngeal nerve monitoring. Otolaryngol Head Neck Surg 1991;105:372-375.
    • (1991) Otolaryngol Head Neck Surg , vol.105 , pp. 372-375
    • Rice, D.H.1    Cone-Wesson, B.2
  • 12
    • 0031809285 scopus 로고    scopus 로고
    • Use of a disposable electrode for recurrent laryngeal nerve monitoring
    • Srinivasan V, Premachandra DJ: Use of a disposable electrode for recurrent laryngeal nerve monitoring. J Laryngol Otol 1998;112:561-564.
    • (1998) J Laryngol Otol , vol.112 , pp. 561-564
    • Srinivasan, V.1    Premachandra, D.J.2
  • 16
    • 0036734801 scopus 로고    scopus 로고
    • Comparison of various methods of electromyographic monitoring of the recurrent laryngeal nerve in thyroid surgery
    • Tschopp KP, Gottardo C: Comparison of various methods of electromyographic monitoring of the recurrent laryngeal nerve in thyroid surgery. Ann Otol Rhinol Laryngol 2002;111:811-816.
    • (2002) Ann Otol Rhinol Laryngol , vol.111 , pp. 811-816
    • Tschopp, K.P.1    Gottardo, C.2
  • 17
    • 0034975443 scopus 로고    scopus 로고
    • Intraoperative pediatric laryngeal electromyography: Experience and caveats with monopolar electrodes
    • Wohl DL, Kilpatrick JK, Leshner RT, Shaia WT: Intraoperative pediatric laryngeal electromyography: experience and caveats with monopolar electrodes. Ann Otol Rhinol Laryngol 2001;110:524-531.
    • (2001) Ann Otol Rhinol Laryngol , vol.110 , pp. 524-531
    • Wohl, D.L.1    Kilpatrick, J.K.2    Leshner, R.T.3    Shaia, W.T.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.