메뉴 건너뛰기




Volumn 109 PART 2, Issue , 2003, Pages 463-474

Removing variable heat rate effects from borehole tests

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHMS; BOREHOLES; ESTIMATION; HEAT EXCHANGERS; SOILS; THERMAL CONDUCTIVITY;

EID: 0242543986     PISSN: 00012505     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (35)

References (18)
  • 1
    • 0242628916 scopus 로고    scopus 로고
    • Minimum duration of in-situ tests on vertical boreholes
    • Beier, R.A., and M.D. Smith. 2003. Minimum duration of in-situ tests on vertical boreholes. ASHRAE Transactions 109(2).
    • (2003) ASHRAE Transactions , vol.109 , Issue.2
    • Beier, R.A.1    Smith, M.D.2
  • 2
    • 0036459594 scopus 로고    scopus 로고
    • Borehole thermal resistance from line-source model of in-situ tests
    • Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • Beier, R.A., and M.D. Smith. 2002. Borehole thermal resistance from line-source model of in-situ tests. ASHRAE Transactions 108(2). Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • (2002) ASHRAE Transactions , vol.108 , Issue.2
    • Beier, R.A.1    Smith, M.D.2
  • 3
    • 0008927852 scopus 로고
    • Pressure drawdown and buildup in the presence of radial discontinuities
    • Bixel, H.C., and H.K. van Poollen. 1967. Pressure drawdown and buildup in the presence of radial discontinuities. SPE Journal 7(3): 301-309.
    • (1967) SPE Journal , vol.7 , Issue.3 , pp. 301-309
    • Bixel, H.C.1    Van Poollen, H.K.2
  • 4
    • 0001002697 scopus 로고
    • Use of pressure derivative in well-test interpretation
    • Bourdet, D., J.A. Ayoub, and Y.M. Pirard. 1989. Use of pressure derivative in well-test interpretation. SPE Formation Evaluation 4(2): 293-302.
    • (1989) SPE Formation Evaluation , vol.4 , Issue.2 , pp. 293-302
    • Bourdet, D.1    Ayoub, J.A.2    Pirard, Y.M.3
  • 7
    • 0032725998 scopus 로고    scopus 로고
    • Analysis of pressure/flow-rate data with the pressure-history-recovery method
    • Gilly, P., and R.N. Horne. 1999. Analysis of pressure/flow-rate data with the pressure-history-recovery method. SPE Reservoir Evaluation and Engineering 2(4): 314-324.
    • (1999) SPE Reservoir Evaluation and Engineering , vol.2 , Issue.4 , pp. 314-324
    • Gilly, P.1    Horne, R.N.2
  • 8
    • 0032305923 scopus 로고    scopus 로고
    • Development of an equivalent diameter expression for vertical U-tubes used in ground-coupled heat pumps
    • Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • Gu, Y., and D.L. O'Neal. 1998. Development of an equivalent diameter expression for vertical U-tubes used in ground-coupled heat pumps. ASHRAE Transactions 104(2): 347-355. Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • (1998) ASHRAE Transactions , vol.104 , Issue.2 , pp. 347-355
    • Gu, Y.1    O'Neal, D.L.2
  • 10
    • 0242618876 scopus 로고
    • Reservoir limit test on gas wells
    • Jones, P. 1962. Reservoir limit test on gas wells. Journal of Petroleum Technology 14(6): 613-619.
    • (1962) Journal of Petroleum Technology , vol.14 , Issue.6 , pp. 613-619
    • Jones, P.1
  • 11
    • 0033713436 scopus 로고    scopus 로고
    • Field test for ground thermal properties - Methods and impact on ground-source heat pump design
    • Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • Kavanaugh, S.P. 2000. Field test for ground thermal properties - Methods and impact on ground-source heat pump design. ASHRAE Transactions 106(1): 851-855. Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • (2000) ASHRAE Transactions , vol.106 , Issue.1 , pp. 851-855
    • Kavanaugh, S.P.1
  • 12
    • 0025398991 scopus 로고
    • Numerical deconvolution of wellbore pressure and flow rate
    • Kuchuk, F.J., R.G. Carter, and L. Ayestran. 1990. Numerical deconvolution of wellbore pressure and flow rate. SPE Formation Evaluation 5(1): 53-59.
    • (1990) SPE Formation Evaluation , vol.5 , Issue.1 , pp. 53-59
    • Kuchuk, F.J.1    Carter, R.G.2    Ayestran, L.3
  • 13
    • 0242703015 scopus 로고    scopus 로고
    • Numerical Laplace transformation of sampled data for well-test analysis
    • Onur, M., and A.C. Reynolds. 1998. Numerical Laplace transformation of sampled data for well-test analysis. SPE Reservoir Evaluation and Engineering 1(3): 268-277.
    • (1998) SPE Reservoir Evaluation and Engineering , vol.1 , Issue.3 , pp. 268-277
    • Onur, M.1    Reynolds, A.C.2
  • 15
    • 0032654162 scopus 로고    scopus 로고
    • Determining effective soil formation thermal properties from field data using a parameter estimation technique
    • Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • Shonder, J.A., and J.V. Beck. 1999. Determining effective soil formation thermal properties from field data using a parameter estimation technique. ASHRAE Transactions 105(1): 458-466. Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • (1999) ASHRAE Transactions , vol.105 , Issue.1 , pp. 458-466
    • Shonder, J.A.1    Beck, J.V.2
  • 16
    • 0033684567 scopus 로고    scopus 로고
    • Field test of a new method for determining soil formation thermal conductivity and borehole resistance
    • Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • Shonder, J.A., and J.V. Beck. 2000. Field test of a new method for determining soil formation thermal conductivity and borehole resistance. ASHRAE Transactions 106(1): 843-850. Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • (2000) ASHRAE Transactions , vol.106 , Issue.1 , pp. 843-850
    • Shonder, J.A.1    Beck, J.V.2
  • 17
    • 84976835846 scopus 로고
    • Algorithm 368, numerical inversion of Laplace transforms [D5]
    • Stehfast, H. 1970. Algorithm 368, numerical inversion of Laplace transforms [D5]. Communications of the ACM 13(1): 47-49.
    • (1970) Communications of the ACM , vol.13 , Issue.1 , pp. 47-49
    • Stehfast, H.1
  • 18
    • 0033309869 scopus 로고    scopus 로고
    • A short time step response factor model for vertical ground loop heat exchangers
    • Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • Yavuzturk, C., and J.D. Spitler 1999. A short time step response factor model for vertical ground loop heat exchangers. ASHRAE Transactions 105(2): 475-485. Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • (1999) ASHRAE Transactions , vol.105 , Issue.2 , pp. 475-485
    • Yavuzturk, C.1    Spitler, J.D.2