메뉴 건너뛰기




Volumn 43, Issue 11, 2003, Pages 1611-1614

Weakening or loss of antibody reactivity after prewarm technique

Author keywords

[No Author keywords available]

Indexed keywords

AUTOANTIBODY;

EID: 0242523646     PISSN: 00411132     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1537-2995.2003.00563.x     Document Type: Article
Times cited : (7)

References (11)
  • 1
    • 0028033355 scopus 로고
    • Misidentification of anti-Vel due to inappropriate use of prewarming and adsorption techniques
    • Storry JR, Mallory D. Misidentification of anti-Vel due to inappropriate use of prewarming and adsorption techniques. Immunohematology 1994;10:83-6.
    • (1994) Immunohematology , vol.10 , pp. 83-86
    • Storry, J.R.1    Mallory, D.2
  • 2
    • 0242572962 scopus 로고
    • Failure to detect potentially significant antibodies in prewarmed tests
    • Judd WJ, Steiner EA, Knafl P, Davenport RD. Failure to detect potentially significant antibodies in prewarmed tests. Transfusion 1995;35:68S.
    • (1995) Transfusion , vol.35
    • Judd, W.J.1    Steiner, E.A.2    Knafl, P.3    Davenport, R.D.4
  • 3
    • 0242488809 scopus 로고
    • Prewarming technique with a polyethylene glycol additive solution
    • Champagne K, Spruell P, Chen J, Moulds M. Prewarming technique with a polyethylene glycol additive solution. Transfusion 1995;35:67S.
    • (1995) Transfusion , vol.35
    • Champagne, K.1    Spruell, P.2    Chen, J.3    Moulds, M.4
  • 4
    • 0028881586 scopus 로고
    • Controversies in transfusion medicine. Prewarmed tests: Pro-why, when, and how-not if
    • Mallory D. Controversies in transfusion medicine. Prewarmed tests: pro-why, when, and how-not if. Transfusion 1995;35:268-70.
    • (1995) Transfusion , vol.35 , pp. 268-270
    • Mallory, D.1
  • 5
    • 0028859253 scopus 로고
    • Controversies in transfusion medicine. Prewarmed tests: Con
    • Judd WJ. Controversies in transfusion medicine. Prewarmed tests: con. Transfusion 1995;35:271-5.
    • (1995) Transfusion , vol.35 , pp. 271-275
    • Judd, W.J.1
  • 6
    • 4244023874 scopus 로고    scopus 로고
    • Comparison of prewarmed techniques: With and without enhancements
    • Kilsby MA. Comparison of prewarmed techniques: with and without enhancements. Transfusion 1999;39:104S.
    • (1999) Transfusion , vol.39
    • Kilsby, M.A.1
  • 7
    • 25044455508 scopus 로고    scopus 로고
    • Sensitivity of prewarmed tests in pretransfusion testing
    • Hundric-Haspl Z, Jurakovic-Loncar N, Tomicic M, et al. Sensitivity of prewarmed tests in pretransfusion testing. Vox Sang 2000;78(Suppl 1):P099.
    • (2000) Vox Sang , vol.78 , Issue.SUPPL. 1
    • Hundric-Haspl, Z.1    Jurakovic-Loncar, N.2    Tomicic, M.3
  • 8
    • 0003809510 scopus 로고    scopus 로고
    • Bethesda, MD: American Association of Blood Banks
    • Brecher ME, ed. Technical manual, 14th ed. Bethesda, MD: American Association of Blood Banks, 2002.
    • (2002) Technical Manual, 14th Ed.
    • Brecher, M.E.1
  • 9
    • 0002435877 scopus 로고
    • Autoimmune hemolytic anemia
    • Garratty G, ed. New York: Dekker
    • Garratty G. Autoimmune hemolytic anemia. In: Garratty G, ed. Immunobiology of transfusion medicine. New York: Dekker, 1994:493-521.
    • (1994) Immunobiology of Transfusion Medicine , pp. 493-521
    • Garratty, G.1
  • 11
    • 0023340673 scopus 로고
    • Polyethylene glycol. A new potentiator of red blood cell antigen-antibody reactions
    • Nance SJ, Garratty G. Polyethylene glycol. A new potentiator of red blood cell antigen-antibody reactions. Am J Clin Pathol 1987;87:633-5.
    • (1987) Am J Clin Pathol , vol.87 , pp. 633-635
    • Nance, S.J.1    Garratty, G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.