Indexed keywords
ARTIFICIAL INTELLIGENCE;
DOSIMETRY;
FUZZY CONTROL;
PATIENT TREATMENT;
INTENSITY-MODULATED RADIATION THERAPY (IMRT);
RADIOTHERAPY;
ALGORITHM;
ANALYTIC METHOD;
ANALYTICAL PARAMETERS;
ARTICLE;
ARTIFICIAL INTELLIGENCE;
AUTOMATION;
COMPUTER AIDED DESIGN;
COMPUTER SIMULATION;
CONTROLLED STUDY;
DOSIMETRY;
EMPIRICISM;
HISTOGRAM;
HUMAN;
ONLINE SYSTEM;
PRIORITY JOURNAL;
PROCESS OPTIMIZATION;
RADIATION DOSE DISTRIBUTION;
RADIOTHERAPY;
TREATMENT PLANNING;
ALGORITHMS;
ARTIFICIAL INTELLIGENCE;
BODY BURDEN;
COMPUTER SIMULATION;
FEASIBILITY STUDIES;
FUZZY LOGIC;
HUMANS;
MODELS, BIOLOGICAL;
QUALITY CONTROL;
RADIATION PROTECTION;
RADIOMETRY;
RADIOTHERAPY DOSAGE;
RADIOTHERAPY PLANNING, COMPUTER-ASSISTED;
RADIOTHERAPY, CONFORMAL;
REPRODUCIBILITY OF RESULTS;
SENSITIVITY AND SPECIFICITY;
SPINAL NEOPLASMS;
1
0031967470
Optimization of intensity modulated beams with volume constraints using two methods: Cost function minimization and projections onto convex sets
Cho P S and Lee S 1998 Optimization of intensity modulated beams with volume constraints using two methods: cost function minimization and projections onto convex sets Med. Phys. 25 435-43
(1998)
Med. Phys.
, vol.25
, pp. 435-443
Cho, P.S.1
Lee, S.2
2
0031886970
A continuous penalty function method for inverse treatment planning
Hristov D H and Fallone B G 1998 A continuous penalty function method for inverse treatment planning Med. Phys. 25 208-23
(1998)
Med. Phys.
, vol.25
, pp. 208-223
Hristov, D.H.1
Fallone, B.G.2
3
0030699173
Inverse radiation treatment planning using the dynamically penalized likelihood method
Llacer J 1997 Inverse radiation treatment planning using the dynamically penalized likelihood method Med. Phys. 24 1751-64
(1997)
Med. Phys.
, vol.24
, pp. 1751-1764
Llacer, J.1
4
0033994713
Optimization of inverse treatment planning using a fuzzy weight function
Li R P and Yin F F 2000 Optimization of inverse treatment planning using a fuzzy weight function Med. Phys. 27 691-700
(2000)
Med. Phys.
, vol.27
, pp. 691-700
Li, R.P.1
Yin, F.F.2
6
0033021924
Variation method for inverse treatment
Liu Y, Yin F F and Gao Q 1999 Variation method for inverse treatment Med. Phys. 26 356-63
(1999)
Med. Phys.
, vol.26
, pp. 356-363
Liu, Y.1
Yin, F.F.2
Gao, Q.3
7
0025825231
Treatment plan optimization using linear programming
Rosen I and Lane R G 1991 Treatment plan optimization using linear programming Med. Phys. 18 141-52
(1991)
Med. Phys.
, vol.18
, pp. 141-152
Rosen, I.1
Lane, R.G.2
8
0031895424
A gradient inverse planning algorithm with dose-volume constraints
Spirou S V and Chui C S 1998 A gradient inverse planning algorithm with dose-volume constraints Med. Phys. 25 321-33
(1998)
Med. Phys.
, vol.25
, pp. 321-333
Spirou, S.V.1
Chui, C.S.2
10
0024417873
Optimization of conformal radiotherapy dose distributions by simulated annealing
Webb S 1989 Optimization of conformal radiotherapy dose distributions by simulated annealing Phys. Med. Biol. 34 1349-70
(1989)
Phys. Med. Biol.
, vol.34
, pp. 1349-1370
Webb, S.1
12
0034003282
Algorithms and functionality of an intensity modulated radiotherapy optimization system
Wu Q and Mohan R 2000 Algorithms and functionality of an intensity modulated radiotherapy optimization system Med. Phys. 27 701-11
(2000)
Med. Phys.
, vol.27
, pp. 701-711
Wu, Q.1
Mohan, R.2
13
0035055483
An optimization method for importance factors and beam weights based on genetic algorithms for radiotherapy treatment planning
Wu X G and Zhu Y P 2001 An optimization method for importance factors and beam weights based on genetic algorithms for radiotherapy treatment planning Phys. Med. Biol. 46 1085-99
(2001)
Phys. Med. Biol.
, vol.46
, pp. 1085-1099
Wu, X.G.1
Zhu, Y.P.2
14
0032859241
Optimization of importance factors in inverse planning
Xing L and Li J 1999a Optimization of importance factors in inverse planning Phys. Med. Biol. 44 2525-36
(1999)
Phys. Med. Biol.
, vol.44
, pp. 2525-2536
Xing, L.1
Li, J.2
15
0032692577
Estimation theory and model parameter selection for therapeutic treatment plan optimization
Xing L and Li J 1999b Estimation theory and model parameter selection for therapeutic treatment plan optimization Med. Phys. 26 2348-58
(1999)
Med. Phys.
, vol.26
, pp. 2348-2358
Xing, L.1
Li, J.2
16
0142025627
Fuzzy logic guided inverse treatment planning
Yan H, Yin F F, Guan H Q and Kim J H 2003 Fuzzy logic guided inverse treatment planning Med. Phys. 30 2675-85
(2003)
Med. Phys.
, vol.30
, pp. 2675-2685
Yan, H.1
Yin, F.F.2
Guan, H.Q.3
Kim, J.H.4