메뉴 건너뛰기




Volumn 29, Issue 10, 2003, Pages 1763-1769

Inability to predict outcome of acute respiratory distress syndrome in children when using high frequency oscillation

Author keywords

Acute respiratory distress syndrome; High frequency ventilation; Mechanical; Mechanical ventilation; Pediatrics; Respiratory failure; Ventilators

Indexed keywords

ADULT RESPIRATORY DISTRESS SYNDROME; ARTERIAL GAS; ARTICLE; ARTIFICIAL VENTILATION; CHILD; CLINICAL ARTICLE; HIGH FREQUENCY OSCILLATION; HUMAN; INFANT; INTENSIVE CARE; MORTALITY; MULTIPLE ORGAN FAILURE; NEWBORN; OXYGENATION; RESPIRATORY FAILURE; RETROSPECTIVE STUDY; SURVIVAL; TREATMENT OUTCOME;

EID: 0242509216     PISSN: 03424642     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00134-003-1928-3     Document Type: Article
Times cited : (10)

References (29)
  • 1
    • 0031942649 scopus 로고    scopus 로고
    • Ventilator-induced lung injury: Lessons from experimental studies
    • Dreyfuss D, Saumon G (1998) Ventilator-induced lung injury: lessons from experimental studies. Am J Respir Crit Care Med 157:294-323
    • (1998) Am J Respir Crit Care Med , vol.157 , pp. 294-323
    • Dreyfuss, D.1    Saumon, G.2
  • 3
    • 0343893748 scopus 로고    scopus 로고
    • Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome
    • The Acute Respiratory Distress Syndrome Network (2000) Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. N Engl J Med 342:1301-1308
    • (2000) N Engl J Med , vol.342 , pp. 1301-1308
  • 4
    • 0027949271 scopus 로고
    • Prospective, randomized comparison of high-frequency oscillatory ventilation and conventional mechanical ventilation in pediatric respiratory failure
    • Arnold JH, Hanson JH, Toro-Figuero LO, Gutierrez J, Berens RJ, Anglin DL (1994) Prospective, randomized comparison of high-frequency oscillatory ventilation and conventional mechanical ventilation in pediatric respiratory failure. Crit Care Med 22:1530-1539
    • (1994) Crit Care Med , vol.22 , pp. 1530-1539
    • Arnold, J.H.1    Hanson, J.H.2    Toro-Figuero, L.O.3    Gutierrez, J.4    Berens, R.J.5    Anglin, D.L.6
  • 5
    • 0029838134 scopus 로고    scopus 로고
    • Predicting outcome in children with severe acute respiratory failure treated with high-frequency ventilation
    • Sarnaik AP, Meert KL, Pappas MD, Simpson PM, Lieh-Lai MW, Heidemann SM. (1996) Predicting outcome in children with severe acute respiratory failure treated with high-frequency ventilation. Crit Care Med 24:1396-1402
    • (1996) Crit Care Med , vol.24 , pp. 1396-1402
    • Sarnaik, A.P.1    Meert, K.L.2    Pappas, M.D.3    Simpson, P.M.4    Lieh-Lai, M.W.5    Heidemann, S.M.6
  • 8
    • 0028223811 scopus 로고
    • Timing and predictors of death in pediatric patients with multiple organ system failure
    • Proulx F, Gauthier M, Nadeau D, Lacroix J, Farrell CA (1994) Timing and predictors of death in pediatric patients with multiple organ system failure. Crit Care Med 22:1025-1031
    • (1994) Crit Care Med , vol.22 , pp. 1025-1031
    • Proulx, F.1    Gauthier, M.2    Nadeau, D.3    Lacroix, J.4    Farrell, C.A.5
  • 9
    • 0029083676 scopus 로고
    • Predicting death in pediatric patients with acute respiratory failure
    • Timmons OD, Havens PL, Fackler JC, and the Pediatric Critical Care Study Group and the Extracorporeal Life Support Organization (1995) Predicting death in pediatric patients with acute respiratory failure. Chest 108:789-797
    • (1995) Chest , vol.108 , pp. 789-797
    • Timmons, O.D.1    Havens, P.L.2    Fackler, J.C.3
  • 10
    • 0018135917 scopus 로고
    • A method for comparing survival of burn patients to a standard survival curve
    • Flora JD (1978) A method for comparing survival of burn patients to a standard survival curve. J Trauma 18:701-705
    • (1978) J Trauma , vol.18 , pp. 701-705
    • Flora, J.D.1
  • 11
    • 0031834452 scopus 로고    scopus 로고
    • Multiple system organ failure: Is mechanical ventilation a contributing factor?
    • Slutsky AS, Tremblay LN (1998) Multiple system organ failure: is mechanical ventilation a contributing factor? Am J Respir Crit Care Med 157:1721-1725
    • (1998) Am J Respir Crit Care Med , vol.157 , pp. 1721-1725
    • Slutsky, A.S.1    Tremblay, L.N.2
  • 12
    • 0030902502 scopus 로고    scopus 로고
    • High-frequency oscillatory ventilation for adult respiratory distress syndrome: Let's get it right this time!
    • Froese AB (1997) High-frequency oscillatory ventilation for adult respiratory distress syndrome: let's get it right this time! Crit Care Med 24:906-908
    • (1997) Crit Care Med , vol.24 , pp. 906-908
    • Froese, A.B.1
  • 13
    • 0028231123 scopus 로고
    • High-frequency ventilation
    • Clark RH (1994) High-frequency ventilation. J Pediatr 124:661-670
    • (1994) J Pediatr , vol.124 , pp. 661-670
    • Clark, R.H.1
  • 14
    • 0031267683 scopus 로고    scopus 로고
    • Elective high-frequency oscillatory ventilation versus conventional ventilation in preterm infants with pulmonary dysfunction: Systematic review and meta-analysis
    • Cited 25 April 2001
    • Bhuta T, Henderson-Smart DJ (1997) Elective high-frequency oscillatory ventilation versus conventional ventilation in preterm infants with pulmonary dysfunction: systematic review and meta-analysis. Pediatrics 100 (5): e6. Available online at: http://www.pediatrics.org/cgi/content/ full/100/5/e6. Cited 25 April 2001
    • (1997) Pediatrics , vol.100 , Issue.5
    • Bhuta, T.1    Henderson-Smart, D.J.2
  • 16
    • 0027435436 scopus 로고
    • High frequency ventilation for acute pediatric respiratory failure
    • Rosenberg RB, Broner CW, Peters KJ, Anglin DL (1993) High frequency ventilation for acute pediatric respiratory failure. Chest 104:1216-1221
    • (1993) Chest , vol.104 , pp. 1216-1221
    • Rosenberg, R.B.1    Broner, C.W.2    Peters, K.J.3    Anglin, D.L.4
  • 17
    • 0027418672 scopus 로고
    • High-frequency oscillatory ventilation in pediatric respiratory failure
    • Arnold JH, Truog RD, Thompson JE, Fackler JC (1993) High-frequency oscillatory ventilation in pediatric respiratory failure. Crit Care Med 21:272-278
    • (1993) Crit Care Med , vol.21 , pp. 272-278
    • Arnold, J.H.1    Truog, R.D.2    Thompson, J.E.3    Fackler, J.C.4
  • 19
    • 0027221884 scopus 로고
    • Adult respiratory distress syndrome in children: Associated disease, clinical course and predictors of death
    • Davis SL, Furman DP, Costarino AT (1993) Adult respiratory distress syndrome in children: associated disease, clinical course and predictors of death. J Pediatr 123:35-45
    • (1993) J Pediatr , vol.123 , pp. 35-45
    • Davis, S.L.1    Furman, D.P.2    Costarino, A.T.3
  • 20
    • 0026663012 scopus 로고
    • Acute hypoxemic respiratory failure in infants and children: Clinical and pathologic characteristics
    • DeBruin W, Notterman DA, Magid M, Godwin T, Johnston S (1992) Acute hypoxemic respiratory failure in infants and children: clinical and pathologic characteristics. Crit Care Med 20:1223-1234
    • (1992) Crit Care Med , vol.20 , pp. 1223-1234
    • DeBruin, W.1    Notterman, D.A.2    Magid, M.3    Godwin, T.4    Johnston, S.5
  • 21
    • 0034604129 scopus 로고    scopus 로고
    • The acute respiratory distress syndrome
    • Ware LB, Matthay MA (2000) The acute respiratory distress syndrome. N Engl J Med 342:1334-1349
    • (2000) N Engl J Med , vol.342 , pp. 1334-1349
    • Ware, L.B.1    Matthay, M.A.2
  • 22
    • 0029151333 scopus 로고
    • New concepts in the treatment of children with acute respiratory distress syndrome
    • Paulson TE, Spear RM, Peterson BM (1995) New concepts in the treatment of children with acute respiratory distress syndrome. J Pediatr 127:163-175
    • (1995) J Pediatr , vol.127 , pp. 163-175
    • Paulson, T.E.1    Spear, R.M.2    Peterson, B.M.3
  • 23
    • 0033510729 scopus 로고    scopus 로고
    • Nitric oxide in acute hypoxic respiratory failure: From the bench to the bedside and back again
    • Bohn D (1999) Nitric oxide in acute hypoxic respiratory failure: from the bench to the bedside and back again. J Pediatr 134:387-389
    • (1999) J Pediatr , vol.134 , pp. 387-389
    • Bohn, D.1
  • 25
    • 0028798336 scopus 로고
    • Improved survival of patients with acute respiratory distress syndrome (ARDS): 1983-1993
    • Milberg JA, Davis DR, Steinberg KP, Hudson LD (1995) Improved survival of patients with acute respiratory distress syndrome (ARDS): 1983-1993. JAMA 273:306-309
    • (1995) JAMA , vol.273 , pp. 306-309
    • Milberg, J.A.1    Davis, D.R.2    Steinberg, K.P.3    Hudson, L.D.4
  • 27
    • 0032880553 scopus 로고    scopus 로고
    • The open lung during small tidal volume ventilation: Concepts of recruitment and "optimal" positive end-expiratory pressure
    • Rimensberger PC, Cox PN, Frndova H, Bryan C (1999) The open lung during small tidal volume ventilation: concepts of recruitment and "optimal" positive end-expiratory pressure. Crit Care Med 27:1946-1952
    • (1999) Crit Care Med , vol.27 , pp. 1946-1952
    • Rimensberger, P.C.1    Cox, P.N.2    Frndova, H.3    Bryan, C.4
  • 28
    • 0033939423 scopus 로고    scopus 로고
    • Lung recruitment and lung volume maintenance: A strategy for improving oxygenation and preventing lung injury during both conventional mechanical ventilation and high-frequency oscillation
    • Rimensberger PC, Pache JC, McKerlie C, Frndova H, Cox P (2000) Lung recruitment and lung volume maintenance: a strategy for improving oxygenation and preventing lung injury during both conventional mechanical ventilation and high-frequency oscillation. Intensive Care Med 26:745-755
    • (2000) Intensive Care Med , vol.26 , pp. 745-755
    • Rimensberger, P.C.1    Pache, J.C.2    McKerlie, C.3    Frndova, H.4    Cox, P.5