메뉴 건너뛰기




Volumn 5089, Issue 2, 2003, Pages 991-1000

Implementation of serial amplifying fluorescent polymer arrays for enhanced chemical vapor sensing of landmines

Author keywords

Amplifying fluorescent polymers; Chemical sensing; Explosives detection; Landmines; Sensor array

Indexed keywords

AMPLIFICATION; CHEMICAL SENSORS; FLUORESCENCE; POLYMERS; QUENCHING; SENSOR DATA FUSION;

EID: 0242460356     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.487902     Document Type: Conference Paper
Times cited : (15)

References (10)
  • 1
    • 0033686690 scopus 로고    scopus 로고
    • Detection of Landmines by Amplified Fluorescence Quenching of Polymer Films: A Man Portable Chemical Sniffer for Detection of Ultratrace Concentrations of Explosives Emanating From Landmines
    • M. laGrone, C. Cumming, M. Fisher, M. Fox, S. Jacob, D. Reust, M. Rockley, and E. Towers, "Detection of Landmines by Amplified Fluorescence Quenching of Polymer Films: A Man Portable Chemical Sniffer for Detection of Ultratrace Concentrations of Explosives Emanating From Landmines", Proc. SPIE, Detection and Remediation Technologies for Mines and Minelike Targets V, vol. 4038, part 1, p. 553-562 (2000).
    • (2000) Proc. SPIE, Detection and Remediation Technologies for Mines and Minelike Targets V , vol.4038 , Issue.PART 1 , pp. 553-562
    • LaGrone, M.1    Cumming, C.2    Fisher, M.3    Fox, M.4    Jacob, S.5    Reust, D.6    Rockley, M.7    Towers, E.8
  • 6
    • 0032479021 scopus 로고    scopus 로고
    • Porous Shape Persistent Fluorescent Polymer Films: An Approach to TNT Sensory Materials
    • J.S. Yang, and T.M. Swager, "Porous Shape Persistent Fluorescent Polymer Films: An Approach to TNT Sensory Materials," J. Am. Chem. Soc., 120, 5321-5322 (1998).
    • (1998) J. Am. Chem. Soc. , vol.120 , pp. 5321-5322
    • Yang, J.S.1    Swager, T.M.2
  • 7
    • 0032567214 scopus 로고    scopus 로고
    • Fluorescent Porous Polymer Films as TNT Chemosensors: Electronic and Structural Effects
    • J.S. Yang, and T.M. Swager, "Fluorescent Porous Polymer Films as TNT Chemosensors: Electronic and Structural Effects", J. Am. Chem. Soc., 120, 11864-11873 (1998).
    • (1998) J. Am. Chem. Soc. , vol.120 , pp. 11864-11873
    • Yang, J.S.1    Swager, T.M.2
  • 8
    • 0033728846 scopus 로고    scopus 로고
    • Iptycene-ContainingPoly(aryleneethynylene)s
    • V. Williams, T.M. Swager, "Iptycene-ContainingPoly(aryleneethynylene)s", Macromolecules, 33, 4069-4073 (2000).
    • (2000) Macromolecules , vol.33 , pp. 4069-4073
    • Williams, V.1    Swager, T.M.2
  • 9
    • 0009883254 scopus 로고
    • Methodology for Enhancing the Sensitivity of Fluorescent Chemosensors: Energy Migration in Conjugated Polymers
    • Q. Zhou and T. Swager, "Methodology for Enhancing the Sensitivity of Fluorescent Chemosensors: Energy Migration in Conjugated Polymers", J. Am. Chem Soc., 117, p. 7017-7018 (1995).
    • (1995) J. Am. Chem Soc. , vol.117 , pp. 7017-7018
    • Zhou, Q.1    Swager, T.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.