Limitations Using the Vacuum-Assist Venous Drainage Technique during Cardiopulmonary Bypass Procedures

Author keywords

Cardiopulmonary bypass; Centrifugal; Hollow fiber membrane oxygenator

Indexed keywords

ARTICLE; BLOOD FLOW; BLOOD PUMP; CARDIOPULMONARY BYPASS; EXTRACORPOREAL OXYGENATION; HYDROSTATIC PRESSURE; INTERMETHOD COMPARISON; ORGAN PERFUSION; OXYGENATOR; PUMP DESIGN; SURGICAL TECHNIQUE; VACUUM ASSIST VENOUS DRAINAGE; VENOUS CIRCULATION;

EID: 0242440876     PISSN: 00221058     EISSN: 29698960     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (32)

References (12)
  • 1
    • 0008662827 scopus 로고    scopus 로고
    • Augmented venous return for minimally invasive open heart surgery with selective caval cannulation
    • Jegger D, Tevaearai HT, Horisberger J, et al. Augmented venous return for minimally invasive open heart surgery with selective caval cannulation. Europ J Cardio-Thorac Surg. 1999;16:312-6.
    • (1999) Europ J Cardio-Thorac Surg , vol.16 , pp. 312-316
    • Jegger, D.1    Tevaearai, H.T.2    Horisberger, J.3
  • 2
    • 85160904880 scopus 로고    scopus 로고
    • Limitations of Vacuum Assist Venous Drainage CPB Surgery: Microbubble Transgression from Gas to Liquid Compartment in the Oxygenator
    • Jegger H. Tevaearai, N. Pierrel, J. Horisberger, X. Mueller, L.K von Segesser. Limitations of Vacuum Assist Venous Drainage CPB Surgery: Microbubble Transgression from Gas to Liquid Compartment in the Oxygenator. Thorac Cardiovasc Surg. 2000;48(Suppl 1):110.
    • (2000) Thorac Cardiovasc Surg , vol.48 , Issue.SUPPL. 1 , pp. 110
    • Tevaearai, J.H.1    Pierrel, N.2    Horisberger, J.3    Mueller, X.4    Von Segesser, L.K.5
  • 3
    • 0033918194 scopus 로고    scopus 로고
    • Vacuum assisted cardiopulmonary bypass in minimally invasive cardiac surgery: Feasibility and effects on hemolysis
    • Shin H, Yozu R, Maehara T, et al. Vacuum assisted cardiopulmonary bypass in minimally invasive cardiac surgery: feasibility and effects on hemolysis. Artif Organs. 2000;24:450-3.
    • (2000) Artif Organs , vol.24 , pp. 450-453
    • Shin, H.1    Yozu, R.2    Maehara, T.3
  • 4
    • 0032722193 scopus 로고    scopus 로고
    • Venous air in the bypass circuit: A source of arterial line emboli exacerbated by vacuum assisted drainage
    • Willcox TW, Mitchell SJ, Gorman DF. Venous air in the bypass circuit: a source of arterial line emboli exacerbated by vacuum assisted drainage. Ann Thorac Surg. 1999;68:1285-9.
    • (1999) Ann Thorac Surg , vol.68 , pp. 1285-1289
    • Willcox, T.W.1    Mitchell, S.J.2    Gorman, D.F.3
  • 5
    • 0032464540 scopus 로고    scopus 로고
    • Assisted venous drainage, venous air, and gaseous microemboli transmission into the arterial line: An in-vitro study
    • Rider SP, Simon LV, Rice BJ, Poulton CC. Assisted venous drainage, venous air, and gaseous microemboli transmission into the arterial line: an in-vitro study. J Extra Corp Tech. 1998;30:160-5.
    • (1998) J Extra Corp Tech , vol.30 , pp. 160-165
    • Rider, S.P.1    Simon, L.V.2    Rice, B.J.3    Poulton, C.C.4
  • 6
    • 0033753087 scopus 로고    scopus 로고
    • Assisted venous drainage presents the risk of undetected air microembolism
    • LaPietra A, Grossi EA, Pua BB, et al. Assisted venous drainage presents the risk of undetected air microembolism. J Thorac Cardiovasc Surg. 2000;120:856-63.
    • (2000) J Thorac Cardiovasc Surg , vol.120 , pp. 856-863
    • LaPietra, A.1    Grossi, E.A.2    Pua, B.B.3
  • 7
    • 0029987008 scopus 로고    scopus 로고
    • Emboli generation by the Medtronic Maxima venous reservoir
    • Mitchell SJ, Willcox T, McDougall C, Gorman DF. Emboli generation by the Medtronic Maxima venous reservoir. Perfusion. 1996;11:145-55.
    • (1996) Perfusion , vol.11 , pp. 145-155
    • Mitchell, S.J.1    Willcox, T.2    McDougall, C.3    Gorman, D.F.4
  • 10
    • 0031984688 scopus 로고    scopus 로고
    • Air trapping ability of the Spiralgold® membrane oxygenator: An ex vivo study
    • Mueller XM, Tevaearai HT, van Ness K, et al. Air trapping ability of the Spiralgold® membrane oxygenator: an ex vivo study. Perfusion. 1998;13:53-7.
    • (1998) Perfusion , vol.13 , pp. 53-57
    • Mueller, X.M.1    Tevaearai, H.T.2    Van Ness, K.3
  • 11
    • 0032169972 scopus 로고    scopus 로고
    • In situ control of cardiotomy suction reduces blood trauma
    • Tevaearai HT, Mueller XM, Horisberger J, et al. In situ control of cardiotomy suction reduces blood trauma. ASAIO J. 1998;44: M380-3.
    • (1998) ASAIO J , vol.44
    • Tevaearai, H.T.1    Mueller, X.M.2    Horisberger, J.3
  • 12
    • 0033764185 scopus 로고    scopus 로고
    • Impact of hollow-fiber membrane surface area on oxygenator performance: Dideco D903 Avant vs. a prototype with larger surface area
    • Mueller XM, Tevaearai HT, Jegger D, Boone Y, Augstburger M, von Segesser LK. Impact of hollow-fiber membrane surface area on oxygenator performance: Dideco D903 Avant vs. a prototype with larger surface area. J Extra Corp Tech. 2000;32:152-7.
    • (2000) J Extra Corp Tech , vol.32 , pp. 152-157
    • Mueller, X.M.1    Tevaearai, H.T.2    Jegger, D.3    Boone, Y.4    Augstburger, M.5    Von Segesser, L.K.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.