On clinical loading of osseointegrated implants: A methodological and clinical study
-
Glantz P-O, Rangert B, Svensson A, et al. On clinical loading of osseointegrated implants: A methodological and clinical study. Clin Oral Implants Res 1993; 4: 99-105.
-
(1993)
Clin Oral Implants Res
, vol.4
, pp. 99-105
-
-
Glantz, P.-O.1
Rangert, B.2
Svensson, A.3
-
2
-
-
0033630481
-
Biomaterials and biomechanics of oral and maxillofacial implants: Current status and future developments
-
Brunski JB, Puleo DA, Nanci A. Biomaterials and biomechanics of oral and maxillofacial implants: Current status and future developments. Int J Oral Maxillofac Implants 2000; 15: 15-46.
-
(2000)
Int J Oral Maxillofac Implants
, vol.15
, pp. 15-46
-
-
Brunski, J.B.1
Puleo, D.A.2
Nanci, A.3
-
3
-
-
0348025631
-
Biomechanical considerations for craniofacial implants
-
Brånemark P-I, Tolman DE (eds), Chicago: Quintessence
-
Brunski JB, Skalak R. Biomechanical considerations for craniofacial implants. In: Brånemark P-I, Tolman DE (eds). Osseointegration in Cranofacial Reconstruction. Chicago: Quintessence, 1998: 15-35.
-
(1998)
Osseointegration in Cranofacial Reconstruction
, pp. 15-35
-
-
Brunski, J.B.1
Skalak, R.2
-
4
-
-
0020776467
-
Biomechanical considerations in osseointegrated prostheses
-
Skalak R. Biomechanical considerations in osseointegrated prostheses. J Prosthet Dent 1983; 49: 843-848.
-
(1983)
J Prosthet Dent
, vol.49
, pp. 843-848
-
-
Skalak, R.1
-
5
-
-
0029361203
-
Force and bending moment distribution among osseointegrated dental implants
-
Morgan J, James DF. Force and bending moment distribution among osseointegrated dental implants. J Biomech 1995; 28: 1103-1109.
-
(1995)
J Biomech
, vol.28
, pp. 1103-1109
-
-
Morgan, J.1
James, D.F.2
-
8
-
-
0030238164
-
Effects of fabrication, finishing, and polishing procedures on preload in prostheses using conventional "gold" and plastic cylinders
-
Carr AB, Brunski JB, Hurley E. Effects of fabrication, finishing, and polishing procedures on preload in prostheses using conventional "gold" and plastic cylinders. Int J Oral Maxillofac Implants 1996; 11: 589-598.
-
(1996)
Int J Oral Maxillofac Implants
, vol.11
, pp. 589-598
-
-
Carr, A.B.1
Brunski, J.B.2
Hurley, E.3
-
9
-
-
0030237874
-
Prosthesis misfit and marginal bone loss in edentulous implant patients
-
Jemt T, Book K. Prosthesis misfit and marginal bone loss in edentulous implant patients. Int J Oral Maxillofac Implants 1996; 11: 620-625.
-
(1996)
Int J Oral Maxillofac Implants
, vol.11
, pp. 620-625
-
-
Jemt, T.1
Book, K.2
-
10
-
-
0030277405
-
The response of bone in primates around unloaded dental implants supporting prostheses with different levels of fit
-
Carr AB, Gerard DA, Larsen PE. The response of bone in primates around unloaded dental implants supporting prostheses with different levels of fit. J Prosthet Dent 1996; 76: 500-509.
-
(1996)
J Prosthet Dent
, vol.76
, pp. 500-509
-
-
Carr, A.B.1
Gerard, D.A.2
Larsen, P.E.3
-
11
-
-
0031132982
-
The relationship of some histologic parameters, radiographic evaluations, and Periotest measurements of oral implants: An experimental animal study
-
Caulier H, Naert I, Kalk W, Jansen JA. The relationship of some histologic parameters, radiographic evaluations, and Periotest measurements of oral implants: An experimental animal study. Int J Oral Maxillofac Implants 1997; 12: 380-386.
-
(1997)
Int J Oral Maxillofac Implants
, vol.12
, pp. 380-386
-
-
Caulier, H.1
Naert, I.2
Kalk, W.3
Jansen, J.A.4
-
12
-
-
0030280566
-
A dynamic modal testing technique for noninvasive assessment of bone-dental implant interfaces
-
Elias JJ, Brunski JB, Scarton HA. A dynamic modal testing technique for noninvasive assessment of bone-dental implant interfaces. Int J Oral Maxillofac Implants 1996; 11: 728-734.
-
(1996)
Int J Oral Maxillofac Implants
, vol.11
, pp. 728-734
-
-
Elias, J.J.1
Brunski, J.B.2
Scarton, H.A.3
-
13
-
-
0031152189
-
The application of resonance frequency measurements to study the stability of titanium implants during healing in the rabbit tibia
-
Meredith N, Shagadi F, Alleyne D, Sennerby L, Cawley P. The application of resonance frequency measurements to study the stability of titanium implants during healing in the rabbit tibia. Clin Oral Implants Res 1997; 8: 234-243.
-
(1997)
Clin Oral Implants Res
, vol.8
, pp. 234-243
-
-
Meredith, N.1
Shagadi, F.2
Alleyne, D.3
Sennerby, L.4
Cawley, P.5
-
15
-
-
0001902639
-
Histologic and ultrastructural features of fracture healing
-
Brighton CT, Friedlander G, Lane JM (eds), Chicago: American Academy of Orthopedic Surgeons
-
Schenk R, Hunziker EB. Histologic and ultrastructural features of fracture healing. In: Brighton CT, Friedlander G, Lane JM (eds). Bone Formation and Repair. Chicago: American Academy of Orthopedic Surgeons, 1994: 117-146.
-
(1994)
Bone Formation and Repair
, pp. 117-146
-
-
Schenk, R.1
Hunziker, E.B.2
-
16
-
-
0345775217
-
Material considerations. Biomechanics of Endosseous Implants
-
Watzek G (ed), Chicago: Quintessence
-
Plenk H Jr, Zitter H. Material considerations. In: Watzek G (ed). Biomechanics of Endosseous Implants. Endosseous Implants: Scientific and Clinical Aspects. Chicago: Quintessence, 1996: 63-99.
-
(1996)
Endosseous Implants: Scientific and Clinical Aspects
, pp. 63-99
-
-
Plenk Jr, H.1
Zitter, H.2
-
17
-
-
0024198247
-
Bone tissue interface
-
Roberts WE. Bone tissue interface. J Dent Educ 1988; 52: 804-809.
-
(1988)
J Dent Educ
, vol.52
, pp. 804-809
-
-
Roberts, W.E.1
-
18
-
-
85016033318
-
Mechanical loading of Brånemark fixtures affects interfacial bone modeling and remodeling
-
Hoshaw SJ, Brunski JB, Cochran GVB. Mechanical loading of Brånemark fixtures affects interfacial bone modeling and remodeling. Int J Oral Maxillofac Implants 1994; 9: 345-360.
-
(1994)
Int J Oral Maxillofac Implants
, vol.9
, pp. 345-360
-
-
Hoshaw, S.J.1
Brunski, J.B.2
Cochran, G.V.B.3
-
20
-
-
0033140443
-
In vivo bone response to biomechanical loading at the bonedental implant interface
-
Brunski JB. In vivo bone response to biomechanical loading at the bonedental implant interface. Adv Dent Res 1999; 13: 99-119.
-
(1999)
Adv Dent Res
, vol.13
, pp. 99-119
-
-
Brunski, J.B.1
-
21
-
-
0029411943
-
Effect of surface topology on the osseointegration of implant materials in trabecular bone
-
Wong M, Eulenberger J, Schenk R, Hunziker E. Effect of surface topology on the osseointegration of implant materials in trabecular bone. J Biomed Mater Res 1995; 29: 1567-1576.
-
(1995)
J Biomed Mater Res
, vol.29
, pp. 1567-1576
-
-
Wong, M.1
Eulenberger, J.2
Schenk, R.3
Hunziker, E.4
-
22
-
-
9844263758
-
Mechanical and morphologic investigation of the tensile strength of a bone-hydroxyapatite interface
-
Edwards JT, Brunski JB, Higuchi KW. Mechanical and morphologic investigation of the tensile strength of a bone-hydroxyapatite interface. J Biomed Mater Res 1997; 36: 454-468.
-
(1997)
J Biomed Mater Res
, vol.36
, pp. 454-468
-
-
Edwards, J.T.1
Brunski, J.B.2
Higuchi, K.W.3
-
23
-
-
0026921680
-
Fixture design and overload influence marginal bone loss and fixture success in the Brånemark implant system
-
Quirynen M, Naert I, van Steenberghe D. Fixture design and overload influence marginal bone loss and fixture success in the Brånemark implant system. Clin Oral Implants Res 1992; 3: 104-111.
-
(1992)
Clin Oral Implants Res
, vol.3
, pp. 104-111
-
-
Quirynen, M.1
Naert, I.2
van Steenberghe, D.3
-
25
-
-
0032088918
-
Biological factors contributing to failures of osseointegrated oral implants. II. Etiopathogenesis
-
Esposito M, Hirsch J-M, Lekholm U, Thomsen P. Biological factors contributing to failures of osseointegrated oral implants. II. Etiopathogenesis. Eur J Oral Sci 1998; 106: 721-764.
-
(1998)
Eur J Oral Sci
, vol.106
, pp. 721-764
-
-
Esposito, M.1
Hirsch, J.-M.2
Lekholm, U.3
Thomsen, P.4
-
26
-
-
0031061799
-
Histological evaluation of peri-implant bone at implants subjected to occlusal overload or plaque accumulation
-
Isidor F. Histological evaluation of peri-implant bone at implants subjected to occlusal overload or plaque accumulation. Clin Oral Implants Res 1997; 8: 1-9.
-
(1997)
Clin Oral Implants Res
, vol.8
, pp. 1-9
-
-
Isidor, F.1
-
27
-
-
0025908495
-
The "law of bone transformation": A case of crying "Wolff"?
-
Bertram JEA, Swartz SM. The "law of bone transformation": A case of crying "Wolff"? Biol Rev 1991; 66: 245-273.
-
(1991)
Biol Rev
, vol.66
, pp. 245-273
-
-
Bertram, J.E.A.1
Swartz, S.M.2
-
28
-
-
0002128019
-
The law of adaptive bone remodeling: A case for crying Newton?
-
Odgaard A, Weinans H (eds), Singapore: World Scientific
-
Huiskes R. The law of adaptive bone remodeling: A case for crying Newton? In: Odgaard A, Weinans H (eds). Bone Structure and Remodeling. Singapore: World Scientific, 1995: 15-24.
-
(1995)
Bone Structure and Remodeling
, pp. 15-24
-
-
Huiskes, R.1
-
29
-
-
0002382880
-
The validation of algorithms used to explain adaptive bone remodeling in bone
-
Odgaard A, Weinans H (eds), Singapore: World Scientific
-
Currey JD. The validation of algorithms used to explain adaptive bone remodeling in bone. In: Odgaard A, Weinans H (eds). Bone Structure and Remodeling. Singapore: World Scientific, 1995: 9-13.
-
(1995)
Bone Structure and Remodeling
, pp. 9-13
-
-
Currey, J.D.1
-
30
-
-
0027575141
-
The mechanism of bone remodeling and resorption around press-fitted THA stems
-
van Rietbergen B, Huiskes R, Weinans H, et al. The mechanism of bone remodeling and resorption around press-fitted THA stems. J Biomech 1993; 26: 369-382.
-
(1993)
J Biomech
, vol.26
, pp. 369-382
-
-
van Rietbergen, B.1
Huiskes, R.2
Weinans, H.3
-
31
-
-
0032229511
-
The influence of bone mechanical properties and implant fixation upon bone loading around oral implants
-
van Oosterwyck H, Duyck J, Vandersloten J, et al. The influence of bone mechanical properties and implant fixation upon bone loading around oral implants. Clin Oral Implants Res 1998; 9: 407-418.
-
(1998)
Clin Oral Implants Res
, vol.9
, pp. 407-418
-
-
van Oosterwyck, H.1
Duyck, J.2
Vandersloten, J.3
|