메뉴 건너뛰기




Volumn 175, Issue 4, 2003, Pages 532-535

Accuracy of the sonographic determination of the splenic weight in comparison with the weight at autopsy;Genauigkeit der sonographischen milzgewichtsbestimmung am lebenden im vergleich zum pathologischen korrelat

Author keywords

Autopsy; Sonography; Spleen, measurements; Spleen, weight; Splenectomy

Indexed keywords

ACCURACY; ARTICLE; AUTOPSY; CALCULATION; CORRELATION ANALYSIS; ECHOGRAPHY; HUMAN; MAJOR CLINICAL STUDY; MORPHOMETRICS; PRIORITY JOURNAL; SPLEEN; SPLEEN WEIGHT; SPLENECTOMY;

EID: 0242417557     PISSN: 14389029     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-2003-38435     Document Type: Article
Times cited : (10)

References (16)
  • 1
    • 0022558351 scopus 로고
    • Diagnostische maßnahmen bei splenomegalie
    • Schölmerich J. Diagnostische Maßnahmen bei Splenomegalie. Dtsch Med Wochenschr 1986; 111 (23): 903-905
    • (1986) Dtsch Med Wochenschr , vol.111 , Issue.23 , pp. 903-905
    • Schölmerich, J.1
  • 2
    • 0032771694 scopus 로고    scopus 로고
    • Spleen sizing by ultrasound scan and risk of pneumococcal infection in patients with chronic GVHD: Preliminary observations
    • Picardi M, Selleri C, Rotoli B. Spleen sizing by ultrasound scan and risk of pneumococcal infection in patients with chronic GVHD: preliminary observations. Bone Marrow Transplant 1999; 24 (2): 173-177
    • (1999) Bone Marrow Transplant , vol.24 , Issue.2 , pp. 173-177
    • Picardi, M.1    Selleri, C.2    Rotoli, B.3
  • 3
    • 0032906733 scopus 로고    scopus 로고
    • Sonographic measurement of splenic length: Correlation with measurement at autopsy
    • Loftus WK, Chow LT, Metreweli C. Sonographic measurement of splenic length: correlation with measurement at autopsy. J Clin Ultrasound 1999; 27 (2): 71-74
    • (1999) J Clin Ultrasound , vol.27 , Issue.2 , pp. 71-74
    • Loftus, W.K.1    Chow, L.T.2    Metreweli, C.3
  • 4
    • 0033644794 scopus 로고    scopus 로고
    • Ultrasonographic study on the growth and dimensions of healthy children and adults organs
    • Capaccioli L, Stecco A, Vanzi E, Brizzi E. Ultrasonographic study on the growth and dimensions of healthy children and adults organs. Ital J Anat Embryol 2000; 105 (1): 1-50
    • (2000) Ital J Anat Embryol , vol.105 , Issue.1 , pp. 1-50
    • Capaccioli, L.1    Stecco, A.2    Vanzi, E.3    Brizzi, E.4
  • 5
    • 0021173797 scopus 로고
    • Sonographische milzgrößenbestimmung und milzgewichtsschätzung
    • Frank K, Linhart P, Bettendorf U, Christl HL. Sonographische Milzgrößenbestimmung und Milzgewichtsschätzung. Ultraschall Med 1984; 5 (3): 104-107
    • (1984) Ultraschall Med , vol.5 , Issue.3 , pp. 104-107
    • Frank, K.1    Linhart, P.2    Bettendorf, U.3    Christl, H.L.4
  • 7
    • 0018365528 scopus 로고
    • Correlation between sectional area of the spleen by ultrasonic tomography and actual volume of the removed spleen
    • Koga T. Correlation between sectional area of the spleen by ultrasonic tomography and actual volume of the removed spleen. J Clin Ultrasound 1979; 7 (2): 119-120
    • (1979) J Clin Ultrasound , vol.7 , Issue.2 , pp. 119-120
    • Koga, T.1
  • 9
    • 0022727403 scopus 로고
    • Sonographische milzgrößenbestimmung: Normalmaße beim milzgesunden erwachsenen
    • Frank K, Linhart P, Kortsik C, Wohlenberg H. Sonographische Milzgrößenbestimmung: Normalmaße beim milzgesunden Erwachsenen. Ultraschall Med 1986; 7 (3): 134-137
    • (1986) Ultraschall Med , vol.7 , Issue.3 , pp. 134-137
    • Frank, K.1    Linhart, P.2    Kortsik, C.3    Wohlenberg, H.4
  • 11
    • 0031933935 scopus 로고    scopus 로고
    • Ultrasound assessment of mild splenomegaly: Spleen/kidney ratio
    • Loftus WK, Metreweli C. Ultrasound assessment of mild splenomegaly: spleen/kidney ratio. Pediatr Radiol 1998; 28 (2): 98-100
    • (1998) Pediatr Radiol , vol.28 , Issue.2 , pp. 98-100
    • Loftus, W.K.1    Metreweli, C.2
  • 13
    • 0016639709 scopus 로고
    • Ultrasonographic determination of the splenic size and its clinical usefulness in various liver diseases
    • Koga T, Morikawa Y. Ultrasonographic determination of the splenic size and its clinical usefulness in various liver diseases. Radiology 1975; 115 (1): 157-161
    • (1975) Radiology , vol.115 , Issue.1 , pp. 157-161
    • Koga, T.1    Morikawa, Y.2
  • 15
    • 0031298642 scopus 로고    scopus 로고
    • Automatic detection of ground glass opacities on lung HRCT using multiple neural networks
    • Heitmann KR, Kauczor H, Mildenberger P, Uthmann T, Perl J, Thelen M. Automatic detection of ground glass opacities on lung HRCT using multiple neural networks. Eur Radiol 1997; 7 (9): 1463-1472
    • (1997) Eur Radiol , vol.7 , Issue.9 , pp. 1463-1472
    • Heitmann, K.R.1    Kauczor, H.2    Mildenberger, P.3    Uthmann, T.4    Perl, J.5    Thelen, M.6
  • 16
    • 0035408214 scopus 로고    scopus 로고
    • Discriminatory power of 3.5 MHz convex and 7.5 MHz linear ultrasound probes for the imaging of traumatic splenic lesions: A feasibility study
    • Stengel D, Bauwens K, Sehouli J, Nantke J, Ekkernkamp A. Discriminatory power of 3.5 MHz convex and 7.5 MHz linear ultrasound probes for the imaging of traumatic splenic lesions: a feasibility study. J Trauma 2001; 51 (1): 37-43
    • (2001) J Trauma , vol.51 , Issue.1 , pp. 37-43
    • Stengel, D.1    Bauwens, K.2    Sehouli, J.3    Nantke, J.4    Ekkernkamp, A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.