1
-
-
0029011227
-
European quality assurance network for radiotherapy: Dose measurement procedure
-
Derreumaux S, Chavaudra J, Bridier A, Rossetti V and Dutreix AA. European quality assurance network for radiotherapy: dose measurement procedure. Phys Med Biol 1995: 40; 1191-1209.
-
(1995)
Phys Med Biol
, vol.40
, pp. 1191-1209
-
-
Derreumaux, S.1
Chavaudra, J.2
Bridier, A.3
Rossetti, V.4
Dutreix, A.A.5
-
2
-
-
0034213481
-
The ESTRO-QUALity assurance network (EQUAL)
-
Ferreira IH, Dutreix A, Bridier A, Chavaudra J and Svensson H. The ESTRO-QUALity assurance network (EQUAL). Radiot & Oncol 2000: 55; 273-284.
-
(2000)
Radiot & Oncol
, vol.55
, pp. 273-284
-
-
Ferreira, I.H.1
Dutreix, A.2
Bridier, A.3
Chavaudra, J.4
Svensson, H.5
-
3
-
-
0002809464
-
The IAEA/WHO dosimetry service for radiotherapy centres 1969-1987
-
Svensson H, Hanson GP, Zsdanszky K. The IAEA/WHO dosimetry service for radiotherapy centres 1969-1987. SSDL Newsl 1989: 28; 3-21.
-
(1989)
SSDL Newsl
, vol.28
, pp. 3-21
-
-
Svensson, H.1
Hanson, G.P.2
Zsdanszky, K.3
-
5
-
-
0022343728
-
Italian national program of dosimetry standardization in radiotherapy
-
Scarpa G, Milano F, Renzi R. Italian national program of dosimetry standardization in radiotherapy. Radioter & Oncol 1985: 4; 309-312.
-
(1985)
Radioter & Oncol
, vol.4
, pp. 309-312
-
-
Scarpa, G.1
Milano, F.2
Renzi, R.3
-
6
-
-
0023275905
-
Dose intercomparicon at the radiotherapy centres in The Netherlands. 1. Photon beams under reference conditions and for prostatic cancer treatment
-
Wittkämper FW, Mijnheer BJ, Kleffens HJ. Dose intercomparicon at the radiotherapy centres in The Netherlands. 1. Photon beams under reference conditions and for prostatic cancer treatment. Radioter & Oncol 1987: 9; 33-44.
-
(1987)
Radioter & Oncol
, vol.9
, pp. 33-44
-
-
Wittkämper, F.W.1
Mijnheer, B.J.2
Kleffens, H.J.3
-
7
-
-
0026514193
-
A dosimetric intercomparison of mega-voltage photon beams in UK radiotherapy centres
-
Thwaites DI, Williams JR, Aird EG, Klevenhagen SC, Williams PC. A dosimetric intercomparison of mega-voltage photon beams in UK radiotherapy centres. Phys Med Biol 1992: 2; 445-461.
-
(1992)
Phys Med Biol
, vol.2
, pp. 445-461
-
-
Thwaites, D.I.1
Williams, J.R.2
Aird, E.G.3
Klevenhagen, S.C.4
Williams, P.C.5
-
8
-
-
0034534761
-
Energy correction factors of LiF powder TLDs irradiated in high energy electron beams and applied to mailed dosimetry for Quality Assurance Networks
-
Marre D, Ferreira IH, Bridier A, Björeland A, Svensson H, Dutreix A, Chavaudra J. Energy correction factors of LiF powder TLDs irradiated in high energy electron beams and applied to mailed dosimetry for Quality Assurance Networks. Phys Med Biol 2000: 44; 3657-3674.
-
(2000)
Phys Med Biol
, vol.44
, pp. 3657-3674
-
-
Marre, D.1
Ferreira, I.H.2
Bridier, A.3
Björeland, A.4
Svensson, H.5
Dutreix, A.6
Chavaudra, J.7
-
10
-
-
0033955780
-
The IAEA/WHO postal programme for radiotherapy hospitals
-
Izewska J, Andreo P. The IAEA/WHO postal programme for radiotherapy hospitals. Radiot & Oncol 2000: 54; 65-72.
-
(2000)
Radiot & Oncol
, vol.54
, pp. 65-72
-
-
Izewska, J.1
Andreo, P.2
-
11
-
-
0034658537
-
Transferability of ASTM/NIST alanine/polyethylene recipe at ISS
-
De Angelis C, Fattibene P, Onori S, Petetti E, Bartolotta A, Sansone Santamaria A. Transferability of ASTM/NIST alanine/polyethylene recipe at ISS. Appl Radiat Isot 2000: 52; 1197-1201.
-
(2000)
Appl Radiat Isot
, vol.52
, pp. 1197-1201
-
-
De Angelis, C.1
Fattibene, P.2
Onori, S.3
Petetti, E.4
Bartolotta, A.5
Sansone Santamaria, A.6
-
12
-
-
0034657422
-
Accuracy considerations in EPR dosimetry
-
Nagy V. Accuracy considerations in EPR dosimetry. Appl Radiat Isot 2000: 52; 1039-1050.
-
(2000)
Appl Radiat Isot
, vol.52
, pp. 1039-1050
-
-
Nagy, V.1
-
13
-
-
0030293959
-
Progress towards an alanine/ESR therapy level reference dosimetry service at NPL
-
Sharpe PHG, Rajendran K, Sephton JP. Progress towards an alanine/ESR therapy level reference dosimetry service at NPL. Appl Radiat Isot, 1996: 47; 1171-1175.
-
(1996)
Appl Radiat Isot
, vol.47
, pp. 1171-1175
-
-
Sharpe, P.H.G.1
Rajendran, K.2
Sephton, J.P.3
-
14
-
-
0242273830
-
Comitato per la Standardizzazione della Dosimetria in Radidioterapia. Protocollo per la dosimetria di base nella radioterapia con fasci di fotoni ed elettroni con Ernax da 1 MeV a 40 MeV
-
AIFB (Associazione Italiana di Fisica Biomedica). Comitato per la Standardizzazione della Dosimetria in Radidioterapia. Protocollo per la dosimetria di base nella radioterapia con fasci di fotoni ed elettroni con Ernax da 1 MeV a 40 MeV. Notiziario AIFB 1988: VI; 2
-
(1988)
Notiziario AIFB
, vol.6
, pp. 2
-
-
-
16
-
-
0003806122
-
High-dose dosimetry programme of the IAEA
-
Mehta K. High-dose dosimetry programme of the IAEA. IAEA-TECDOC-1070 1999; 11-18.
-
(1999)
IAEA-TECDOC-1070
, pp. 11-18
-
-
Mehta, K.1
-
17
-
-
0242337157
-
e-Calibrations: Using the internet to deliver calibration services in real time at lower cost
-
Avignon, France. IMRP190, V-A1 237
-
th International Meeting on Radiation Processing, Avignon, France. IMRP190, V-A1 237, 2001 (for more details see the web site http://www.mel.nist.gov/namt/projects/radpro/radproov.htm).
-
(2001)
th International Meeting on Radiation Processing
-
-
Desrosiers, M.1
Nagy, V.2
Puhl, J.3
-
18
-
-
0242337158
-
Alanine dosimetry at NPL - The development of a mailed reference dosimetry service at radiotherapy dose levels
-
Sharpe PHG, Sephton JP. Alanine dosimetry at NPL - The development of a mailed reference dosimetry service at radiotherapy dose levels. IAEA-TECDOC-1070: 1999; 183-189 (for more details see the web site http://www.npl.co.uk/npl/rad/services/mail.html).
-
(1999)
IAEA-TECDOC-1070
, pp. 183-189
-
-
Sharpe, P.H.G.1
Sephton, J.P.2
|