메뉴 건너뛰기




Volumn 28, Issue 5, 2003, Pages 125-130

Is Fibre-optical Hepatovenous Oxymetry Useful in Patients Undergoing Elective Partial Liver Resection?;Eignet sich die Fiberoptische Lebervenenoxymetrie als Zusätzliches Monitoring bei Patienten mit Elektiven Leberteilresektionen?

Author keywords

Clamping of the hilus; Hepatic venous oxygen saturation; Ischemia, early detection; Liver

Indexed keywords

ACCURACY; ADULT; AGED; ARTICLE; ARTIFACT; BALANCED ANESTHESIA; CLINICAL ARTICLE; CONTROLLED STUDY; FEMALE; FIBER OPTICS; HEPATIC VEIN; HUMAN; ISCHEMIA; MALE; OXIMETRY; PARTIAL HEPATECTOMY; PATIENT MONITORING; VENOUS BLOOD;

EID: 0242330654     PISSN: 03234983     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (1)

References (19)
  • 1
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland, J.M., Altman, D.G.: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet I, 307-310, 1986
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 4
    • 4243393203 scopus 로고
    • Perioperative decrease in hepatic venous oxygen saturation affects serum transaminases after liver surgery
    • Kainuma, M., Kimura, N., Nakashima, K., Shimada, Y.: Perioperative decrease in hepatic venous oxygen saturation affects serum transaminases after liver surgery. Anesthesiology 73, A428, 1990
    • (1990) Anesthesiology , vol.73
    • Kainuma, M.1    Kimura, N.2    Nakashima, K.3    Shimada, Y.4
  • 5
  • 8
    • 0029022003 scopus 로고
    • Hepatic, venous catheterization in patients undergoing positive end-expiratory pressure ventilation after OLT: Technique and clinical impact
    • Kaisers, U., Langrehr, J.M., Haack, M., Mohnhaupt, A., Neuhaus, P., Rossaint, R.: Hepatic, venous catheterization in patients undergoing positive end-expiratory pressure ventilation after OLT: technique and clinical impact. Clin. Transplant. 9, 301-306, 1995
    • (1995) Clin. Transplant. , vol.9 , pp. 301-306
    • Kaisers, U.1    Langrehr, J.M.2    Haack, M.3    Mohnhaupt, A.4    Neuhaus, P.5    Rossaint, R.6
  • 10
    • 0032862437 scopus 로고    scopus 로고
    • Thermodiffusion for continuous quantification of hepatic microcirculation - Validation and potential in liver transplantation
    • Klar, E., Kraus, T., Bleyl, J., Newman W.H., Bowman, H.F., Hofman, W.J., von Kummer, R., Bredt, M., Herfarth, C.: Thermodiffusion for continuous quantification of hepatic microcirculation - validation and potential in liver transplantation. Microvasc. Res. 58, 156-166, 1999
    • (1999) Microvasc. Res. , vol.58 , pp. 156-166
    • Klar, E.1    Kraus, T.2    Bleyl, J.3    Newman, W.H.4    Bowman, H.F.5    Hofman, W.J.6    Von Kummer, R.7    Bredt, M.8    Herfarth, C.9
  • 11
    • 0034781644 scopus 로고    scopus 로고
    • Procalcitonin following elective partial liver resection - Origin from the liver?
    • Kretzschmar, M., Krüger, A., Schirrmeister, W.: Procalcitonin following elective partial liver resection - origin from the liver? Acta Anaesthesiol. Scand. 45, 1162-1167, 2001
    • (2001) Acta Anaesthesiol. Scand. , vol.45 , pp. 1162-1167
    • Kretzschmar, M.1    Krüger, A.2    Schirrmeister, W.3
  • 12
    • 0036828719 scopus 로고    scopus 로고
    • Anaesthesia for elective liver resection: Some points should be revisited
    • Lentschener, C., Ozier, Y.: Anaesthesia for elective liver resection: some points should be revisited. Eur J Anaesthesiol 19, 780-788, 2002
    • (2002) Eur. J. Anaesthesiol. , vol.19 , pp. 780-788
    • Lentschener, C.1    Ozier, Y.2
  • 14
    • 0005095221 scopus 로고    scopus 로고
    • Oxygen saturation of hepatic vein reflects the changes in hepatic energy charge in rats
    • Nakashima, K., Kainuma, M., Kimura, N., Kurokawa, T., Shimada, Y.: Oxygen saturation of hepatic vein reflects the changes in hepatic energy charge in rats. Anesthesiology 73, A429, 1999
    • (1999) Anesthesiology , vol.73
    • Nakashima, K.1    Kainuma, M.2    Kimura, N.3    Kurokawa, T.4    Shimada, Y.5
  • 17
    • 0242336491 scopus 로고    scopus 로고
    • Monitoring der zerebralen Oxygenierung
    • Jantzen, J.P., Pieck, J., Burchardi, H. systemed-Verlag Lünen
    • Unterberg, A.W.: Monitoring der zerebralen Oxygenierung. In: Jantzen, J.P., Pieck, J., Burchardi, H.: SHT-Manual. systemed-Verlag Lünen, 136-145, 1998
    • (1998) SHT-Manual , pp. 136-145
    • Unterberg, A.W.1
  • 18
    • 0022397627 scopus 로고
    • Die kontinuierliche Messung der gemischt-venösen Sauerstoffsättigung in der Pulmonalarterie mit der Katheter-Oxymetrie
    • Vettermann, J., Steuer, A.: Die kontinuierliche Messung der gemischt-venösen Sauerstoffsättigung in der Pulmonalarterie mit der Katheter-Oxymetrie. Anästh. Intensivmed. 26, 392-397, 1985
    • (1985) Anästh. Intensivmed. , vol.26 , pp. 392-397
    • Vettermann, J.1    Steuer, A.2
  • 19
    • 0037283813 scopus 로고    scopus 로고
    • Anästhesiologisches Management bei Leberresektion und Kryochirurgie der Leber
    • Zalunardo, M.P.: Anästhesiologisches Management bei Leberresektion und Kryochirurgie der Leber. Anaesthesist 52, 89-97, 2003
    • (2003) Anaesthesist , vol.52 , pp. 89-97
    • Zalunardo, M.P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.