메뉴 건너뛰기




Volumn 7, Issue 5-6, 1998, Pages 300-307

Effects of window position on the air flow distribution in a cross-ventilated residential bedroom

Author keywords

Cross ventilation; Residences

Indexed keywords


EID: 0242316800     PISSN: 1420326X     EISSN: None     Source Type: Journal    
DOI: 10.1177/1420326X9800700507     Document Type: Article
Times cited : (6)

References (11)
  • 1
    • 0348038516 scopus 로고    scopus 로고
    • The philosophy behind ventilation: Past, present and future
    • Nagoya
    • Fanger PO: The philosophy behind ventilation: Past, present and future. Proc Indoor Air '96, Nagoya, 1996, vol 4, pp 3-12.
    • (1996) Proc Indoor Air '96 , vol.4 , pp. 3-12
    • Fanger, P.O.1
  • 3
    • 0001560771 scopus 로고
    • Empirical study on post-occupancy evaluation of housing indoor air environment in Taiwan
    • Chiang CM, Wang WA: Empirical study on post-occupancy evaluation of housing indoor air environment in Taiwan (in Chinese). J Housing Stud 1994;2:107-132.
    • (1994) J Housing Stud , vol.2 , pp. 107-132
    • Chiang, C.M.1    Wang, W.A.2
  • 5
    • 0000024889 scopus 로고    scopus 로고
    • A study of the impacts of outdoor air and living behavior pattern on indoor air quality - Case studies of apartments in Taiwan
    • Nagoya
    • Chiang CM, Chou PC, Wang WA, Chao NT: A study of the impacts of outdoor air and living behavior pattern on indoor air quality - Case studies of apartments in Taiwan. Proc Indoor Air '96, Nagoya, 1996, vol 3, pp 735-740.
    • (1996) Proc Indoor Air '96 , vol.3 , pp. 735-740
    • Chiang, C.M.1    Chou, P.C.2    Wang, W.A.3    Chao, N.T.4
  • 6
    • 2742534399 scopus 로고    scopus 로고
    • A study on the control strategies to improve indoor air quality with outdoor air - Demonstrated by a bathroom design
    • Nagoya
    • Chao NT, Chiang CM, Wang WA, Chou PC: A study on the control strategies to improve indoor air quality with outdoor air - Demonstrated by a bathroom design. Proc Indoor Air '96, Nagoya, 1996, vol 4, pp 387-390.
    • (1996) Proc Indoor Air '96 , vol.4 , pp. 387-390
    • Chao, N.T.1    Chiang, C.M.2    Wang, W.A.3    Chou, P.C.4
  • 7
    • 2742565055 scopus 로고    scopus 로고
    • The reports of the Directorate General of Budget, Accounting and Statistics, Executive Yuan, Taiwan
    • The reports of the Directorate General of Budget, Accounting and Statistics, Executive Yuan, Taiwan (http://www.dgbasey.gov.tw).
  • 8
    • 2742512245 scopus 로고    scopus 로고
    • The reports of the Central Weather Bureau, Taiwan
    • The reports of the Central Weather Bureau, Taiwan (http://www.cwb.gov.tw).
  • 9
    • 2742515594 scopus 로고    scopus 로고
    • PHOENICS-2.0, Concentration, Heat & Momentum Limited, Bakery House, 40 High Street, Wimbledon Village, London, SW19 5AU, UK
    • PHOENICS-2.0, Concentration, Heat & Momentum Limited, Bakery House, 40 High Street, Wimbledon Village, London, SW19 5AU, UK.
  • 11
    • 24244466877 scopus 로고    scopus 로고
    • A study for residential indoor environment index about local mean age and method of ventilation effective performance measurement
    • Chiang CM, Chuah YK: A study for residential indoor environment index about local mean age and method of ventilation effective performance measurement (in Chinese). National Science Council of ROC, NCS 86-2621-E-006-003, 1997.
    • (1997) National Science Council of ROC , vol.NCS 86-2621-E-006-003
    • Chiang, C.M.1    Chuah, Y.K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.