메뉴 건너뛰기




Volumn 28, Issue 6, 2003, Pages 756-774

MRI-guided abdominal intervention

Author keywords

[No Author keywords available]

Indexed keywords

ALCOHOL;

EID: 0242299758     PISSN: 09428925     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00261-003-0048-4     Document Type: Review
Times cited : (7)

References (87)
  • 1
    • 0032620303 scopus 로고    scopus 로고
    • Interventional MR imaging: Percutaneous abdominal and skeletal biopsies and drainages of the abdomen
    • Adam G, Bucker A, Nolte-Ernsting C, et al. Interventional MR imaging: percutaneous abdominal and skeletal biopsies and drainages of the abdomen. Eur Radiol 1999;9:1471-1478
    • (1999) Eur Radiol , vol.9 , pp. 1471-1478
    • Adam, G.1    Bucker, A.2    Nolte-Ernsting, C.3
  • 2
    • 17144461306 scopus 로고    scopus 로고
    • Design and implementation of an interventional MR imaging suite
    • Silverman SG, Jolesz FA, Newman RW, et al. Design and implementation of an interventional MR imaging suite. AJR 1997;168: 1465-1471
    • (1997) AJR , vol.168 , pp. 1465-1471
    • Silverman, S.G.1    Jolesz, F.A.2    Newman, R.W.3
  • 3
    • 0028917177 scopus 로고
    • Interventional magnetic resonance therapy
    • Jolesz F, Silverman SG. Interventional magnetic resonance therapy. Semin Interv Radiol 1995;12:20-27
    • (1995) Semin Interv Radiol , vol.12 , pp. 20-27
    • Jolesz, F.1    Silverman, S.G.2
  • 4
    • 0032613739 scopus 로고    scopus 로고
    • Interventional MR: Interstitial therapy
    • Vogl TJ, Mack MG, Muller PK, et al. Interventional MR: interstitial therapy. Eur Radiol 1999;9:1479-1487
    • (1999) Eur Radiol , vol.9 , pp. 1479-1487
    • Vogl, T.J.1    Mack, M.G.2    Muller, P.K.3
  • 5
    • 0029114935 scopus 로고
    • Interactive biopsy in an open configuration MRI system
    • Silverman SG, Collick BD, Figueira MR, et al. Interactive biopsy in an open configuration MRI system. Radiology 1995;197:175-181
    • (1995) Radiology , vol.197 , pp. 175-181
    • Silverman, S.G.1    Collick, B.D.2    Figueira, M.R.3
  • 6
    • 0031808949 scopus 로고    scopus 로고
    • Interactive MR imaging-guided biopsy and aspiration with a modified clinical C-arm system
    • Lewin JS, Petersilge CA, Hatem S, et al. Interactive MR imaging-guided biopsy and aspiration with a modified clinical C-arm system. AJR 1998;170:1593-1601
    • (1998) AJR , vol.170 , pp. 1593-1601
    • Lewin, J.S.1    Petersilge, C.A.2    Hatem, S.3
  • 7
    • 0034435911 scopus 로고    scopus 로고
    • Interstitial thermo-ablation under MRI guidance for the treatment of fibroids
    • Law P, Regan L. Interstitial thermo-ablation under MRI guidance for the treatment of fibroids. Curr Opin Obstet Gynecol 2000;12: 277-282
    • (2000) Curr Opin Obstet Gynecol , vol.12 , pp. 277-282
    • Law, P.1    Regan, L.2
  • 8
    • 0030670848 scopus 로고    scopus 로고
    • Magnetic resonance imaging-guided abdominal interventional radiology: Laser induced thermotherapy of liver metastasis
    • Vogl TJ, Mack MG, Straub R, et al. Magnetic resonance imaging-guided abdominal interventional radiology: laser induced thermotherapy of liver metastasis. Endoscopy 1997;29:577-583
    • (1997) Endoscopy , vol.29 , pp. 577-583
    • Vogl, T.J.1    Mack, M.G.2    Straub, R.3
  • 9
    • 0033709620 scopus 로고    scopus 로고
    • MR imaging-guided percutaneous cryotherapy of liver tumors: Initial experience
    • Silverman SG, Tuncali K, Adams DF, et al. MR imaging-guided percutaneous cryotherapy of liver tumors: initial experience. Radiology 2000;217:657-664
    • (2000) Radiology , vol.217 , pp. 657-664
    • Silverman, S.G.1    Tuncali, K.2    Adams, D.F.3
  • 10
    • 6844266268 scopus 로고    scopus 로고
    • MR-guided Interstitial cryotherapy of the liver with a novel, nitrogen-cooled cryoprobe
    • Tacke J, Adam G, Speetzen R, et al. MR -guided Interstitial cryotherapy of the liver with a novel, nitrogen-cooled cryoprobe. Magn Reson Med 1998;39:354-360
    • (1998) Magn Reson Med , vol.39 , pp. 354-360
    • Tacke, J.1    Adam, G.2    Speetzen, R.3
  • 11
    • 0003263027 scopus 로고    scopus 로고
    • Percutaneous MR imaging-guided cryotherapy of liver metastases
    • Silverman SG, Tuncali K, Adams DF, et al. Percutaneous MR imaging-guided cryotherapy of liver metastases. Radiology 1999; 213(suppl):122
    • (1999) Radiology , vol.213 , Issue.SUPPL. , pp. 122
    • Silverman, S.G.1    Tuncali, K.2    Adams, D.F.3
  • 12
    • 0031934807 scopus 로고    scopus 로고
    • Interactive MRI-guided radiofrequency interstitial thermal ablation of abdominal tumors: Clinical trial for evaluation of safety and feasibility
    • Lewin JS, Connell CF, Duerek JL, et al. Interactive MRI-guided radiofrequency interstitial thermal ablation of abdominal tumors: clinical trial for evaluation of safety and feasibility. J Magn Reson Imaging 1998;8:40-47
    • (1998) J Magn Reson Imaging , vol.8 , pp. 40-47
    • Lewin, J.S.1    Connell, C.F.2    Duerek, J.L.3
  • 13
    • 0032216633 scopus 로고    scopus 로고
    • Stent placement with real time MRI guidance: Initial animal experiment experiences
    • Buecker A, Neuerburg JM, Adam G, et al. Stent placement with real time MRI guidance: initial animal experiment experiences. Rofo Fortschr Geb Roentgenstr 1998;169:655-657
    • (1998) Rofo Fortschr Geb Roentgenstr , vol.169 , pp. 655-657
    • Buecker, A.1    Neuerburg, J.M.2    Adam, G.3
  • 14
    • 0031036082 scopus 로고    scopus 로고
    • MR-guided intravascular procedures: Initial demonstration in a pig model
    • Wildermuth S, Debatin JF, Leung DA, et al. MR-guided intravascular procedures: initial demonstration in a pig model. Radiology 1997;202:578-583
    • (1997) Radiology , vol.202 , pp. 578-583
    • Wildermuth, S.1    Debatin, J.F.2    Leung, D.A.3
  • 15
    • 0023006852 scopus 로고
    • MR-guided aspiration biopsy: Needle design and clinical trials
    • Mueller PR, Stark DD, Simeone JF, et al. MR-guided aspiration biopsy: needle design and clinical trials. Radiology 1986;161:605-609
    • (1986) Radiology , vol.161 , pp. 605-609
    • Mueller, P.R.1    Stark, D.D.2    Simeone, J.F.3
  • 16
    • 0024524395 scopus 로고
    • Clinical use of a nonferromagnetic needle for magnetic resonance-guided biopsy
    • Mueller PR, Stark DD, Simeone JF, et al. Clinical use of a nonferromagnetic needle for magnetic resonance-guided biopsy. Gastrointest Radiol 1989;14:61-64
    • (1989) Gastrointest Radiol , vol.14 , pp. 61-64
    • Mueller, P.R.1    Stark, D.D.2    Simeone, J.F.3
  • 17
    • 0029005879 scopus 로고
    • Superconducting open configuration MR imaging system for image-guided therapy
    • Schenck JF, Jolesz FA, Roemer PB, et al. Superconducting open configuration MR imaging system for image-guided therapy. Radiology 1995;195:805-814
    • (1995) Radiology , vol.195 , pp. 805-814
    • Schenck, J.F.1    Jolesz, F.A.2    Roemer, P.B.3
  • 18
    • 0024350285 scopus 로고
    • New possibilities and aspects of low-field magnetic resonance tomography
    • Gronemeyer DH, Kaufman L, Rothschild P, et al. New possibilities and aspects of low-field magnetic resonance tomography. Radiol Diagn 1989;30:519-527
    • (1989) Radiol Diagn , vol.30 , pp. 519-527
    • Gronemeyer, D.H.1    Kaufman, L.2    Rothschild, P.3
  • 19
    • 0030052284 scopus 로고    scopus 로고
    • Technique or MR-guided core biopsy of abdominal masses using an open low-field scanner: Feasibility and first clinical results
    • Frahm VC, Gehl HB, Robberg WA. Technique or MR-guided core biopsy of abdominal masses using an open low-field scanner: feasibility and first clinical results. Fortschr Ronigenstr 1996;164:1:62-67
    • (1996) Fortschr Ronigenstr , vol.164 , Issue.1 , pp. 62-67
    • Frahm, V.C.1    Gehl, H.B.2    Robberg, W.A.3
  • 20
    • 0031403387 scopus 로고    scopus 로고
    • MR-guided percutaneous ethanol ablation of liver tissue in a .2-T open MR system: Preliminary study in porcine model
    • Lu DSK, Sinha S, Lucas J, et al. MR-guided percutaneous ethanol ablation of liver tissue in a .2-T open MR system: preliminary study in porcine model. J Magn Reson Imaging 1997;7:303-308
    • (1997) J Magn Reson Imaging , vol.7 , pp. 303-308
    • Lu, D.S.K.1    Sinha, S.2    Lucas, J.3
  • 21
    • 0029933896 scopus 로고    scopus 로고
    • MR-guided biopsy using ultrafast T1- and T2-weighted reordered turbo fast low-angle shot sequences: Feasibility and preliminary clinical applications
    • Mahfouz AE, Rahmouni A, Zylbersztejn C, Mathieu D. MR-guided biopsy using ultrafast T1- and T2-weighted reordered turbo fast low-angle shot sequences: feasibility and preliminary clinical applications. AJR 1996;167:167-169
    • (1996) AJR , vol.167 , pp. 167-169
    • Mahfouz, A.E.1    Rahmouni, A.2    Zylbersztejn, C.3    Mathieu, D.4
  • 22
    • 0031884958 scopus 로고    scopus 로고
    • Remember true-FISP? A high SNR, near 1-second imaging method for T2-like contrast interventional MRI at 0.2 T
    • Duerk JL, Lewin JS, Wendt M, Petersilge C. Remember true-FISP? A high SNR, near 1-second imaging method for T2-like contrast interventional MRI at 0. 2 T. J Magn Reson Imaging 1998;8:203-208
    • (1998) J Magn Reson Imaging , vol.8 , pp. 203-208
    • Duerk, J.L.1    Lewin, J.S.2    Wendt, M.3    Petersilge, C.4
  • 24
    • 0006999749 scopus 로고
    • Anesthesia equipment in remote hospital locations
    • Ehrenwerth J, Eisenkraft JB, eds. St Louis: Mosby
    • Hughes CW, Bell C. Anesthesia equipment in remote hospital locations. In: Ehrenwerth J, Eisenkraft JB, eds. Anesthesia equipment: principles and applications. St Louis: Mosby, 1993:565-587
    • (1993) Anesthesia Equipment: Principles and Applications , pp. 565-587
    • Hughes, C.W.1    Bell, C.2
  • 25
    • 0029896023 scopus 로고    scopus 로고
    • Needle localization in MR guided biopsy and aspiration: Effect of field strength, sequence design, and magnetic field orientation
    • Lewin JS, Duerk JL, Jain JR, et al. Needle localization in MR guided biopsy and aspiration: effect of field strength, sequence design, and magnetic field orientation. AJR 1996;166:1337-1345
    • (1996) AJR , vol.166 , pp. 1337-1345
    • Lewin, J.S.1    Duerk, J.L.2    Jain, J.R.3
  • 26
    • 18744431817 scopus 로고    scopus 로고
    • Interventional magnetic resonance: Realistic prospect or wishful thinking?
    • Gunther RW, Bucher A, Adam G. Interventional magnetic resonance: realistic prospect or wishful thinking? Cardiovasc Interv Radiol 1999;22:187-195
    • (1999) Cardiovasc Interv Radiol , vol.22 , pp. 187-195
    • Gunther, R.W.1    Bucher, A.2    Adam, G.3
  • 27
    • 0031057511 scopus 로고    scopus 로고
    • Biopsy of hepatic dome lesions: Semi-real-time coronal MR guidance technique
    • Lu DSK, Lee H, Farahani K, et al. Biopsy of hepatic dome lesions: semi-real-time coronal MR guidance technique. AJR 1997;168: 737-739
    • (1997) AJR , vol.168 , pp. 737-739
    • Lu, D.S.K.1    Lee, H.2    Farahani, K.3
  • 28
    • 0031715089 scopus 로고    scopus 로고
    • MR-Guided needle aspiration biopsies of hepatic masses using a closed bore magnet
    • Rofsky NM, Yang BM, Scholssberg P, et al. MR-Guided needle aspiration biopsies of hepatic masses using a closed bore magnet. J Comput Assist Tomogr 1998;22:633-637
    • (1998) J Comput Assist Tomogr , vol.22 , pp. 633-637
    • Rofsky, N.M.1    Yang, B.M.2    Scholssberg, P.3
  • 29
    • 0027399141 scopus 로고
    • Real time position monitoring of invasive devices using magnetic resonance imaging
    • Dumoulin CL, Souza P, Darrow RD. Real time position monitoring of invasive devices using magnetic resonance imaging. Magn Reson Med 1993;29:411-415
    • (1993) Magn Reson Med , vol.29 , pp. 411-415
    • Dumoulin, C.L.1    Souza, P.2    Darrow, R.D.3
  • 30
    • 0030757897 scopus 로고    scopus 로고
    • MR-guided cholecystectomy: Assessment of biplanar, real-time needle tracking in three pigs
    • Göhnde SC, Pfammatter T, Steiner P, et al. MR-guided cholecystectomy: assessment of biplanar, real-time needle tracking in three pigs. Cardiovasc Interv Radiol 1997;20:295-299
    • (1997) Cardiovasc Interv Radiol , vol.20 , pp. 295-299
    • Göhnde, S.C.1    Pfammatter, T.2    Steiner, P.3
  • 33
    • 0028899205 scopus 로고
    • Intravascular MR tracking catheter: Preliminary experimental evaluation
    • Leung DA, Debatin JF, Wildermuth S, et al. Intravascular MR tracking catheter: preliminary experimental evaluation. AJR 1995; 164:1265-1270
    • (1995) AJR , vol.164 , pp. 1265-1270
    • Leung, D.A.1    Debatin, J.F.2    Wildermuth, S.3
  • 34
    • 0031934082 scopus 로고    scopus 로고
    • Shifted rotated keyhole imaging and active tip-tracking for interventional procedure guidance
    • Wendt M, Busch M, Wetzler R, et al. Shifted rotated keyhole imaging and active tip-tracking for interventional procedure guidance. J Magn Reson Imaging 1998;8:251-258
    • (1998) J Magn Reson Imaging , vol.8 , pp. 251-258
    • Wendt, M.1    Busch, M.2    Wetzler, R.3
  • 35
    • 0030854650 scopus 로고    scopus 로고
    • Catheter visualization suing locally induced actively controlled field inhomogeneities
    • Glovinski A, Adam G, Buecker A, et al. Catheter visualization suing locally induced actively controlled field inhomogeneities. Magn Reson Med 1997;38:251-258
    • (1997) Magn Reson Med , vol.38 , pp. 251-258
    • Glovinski, A.1    Adam, G.2    Buecker, A.3
  • 36
    • 0032173366 scopus 로고    scopus 로고
    • Device visualization for interventional MRI using local magnetic fields: Basic theory and its application to catheter visualization
    • Glowinski A, Kürsch J, Adam G, et al. Device visualization for interventional MRI using local magnetic fields: basic theory and its application to catheter visualization. IEEE Trans Med Imaging 1998;17:786-793
    • (1998) IEEE Trans Med Imaging , vol.17 , pp. 786-793
    • Glowinski, A.1    Kürsch, J.2    Adam, G.3
  • 37
    • 0029761898 scopus 로고    scopus 로고
    • A technique of MRI guided drainage with an open low field magnet
    • Gehl HB, Frahm C et al. A technique of MRI guided drainage with an open low field magnet. Fortschr Rontgenstr 1996;165:70-73
    • (1996) Fortschr Rontgenstr , vol.165 , pp. 70-73
    • Gehl, H.B.1    Frahm, C.2
  • 38
    • 0023726472 scopus 로고
    • A wire-sheath system for MR-guided biopsy and drainage: Laboratory studies and experience in 10 patients
    • vanSonnenberg E, Hajek P, Gylys-Morin V, et al. A wire-sheath system for MR-guided biopsy and drainage: laboratory studies and experience in 10 patients. AJR 1988;151:815-817
    • (1988) AJR , vol.151 , pp. 815-817
    • Van Sonnenberg, E.1    Hajek, P.2    Gylys-Morin, V.3
  • 39
    • 0035019764 scopus 로고    scopus 로고
    • Real-time MR guidance for inferior vena cava filter placement
    • Buecker A, Neuerburg JM, Adam G, et al. Real-time MR guidance for inferior vena cava filter placement. J Vasc Interv Radiol 2001; 12:753-756
    • (2001) J Vasc Interv Radiol , vol.12 , pp. 753-756
    • Buecker, A.1    Neuerburg, J.M.2    Adam, G.3
  • 40
    • 0033819206 scopus 로고    scopus 로고
    • Real-time MR fluoroscopy for MR-guided iliac artery stent placement
    • Buecker A, Neuerburg JM, Adam GB, et al. Real-time MR fluoroscopy for MR-guided iliac artery stent placement. J Magn Reson Imaging 2000;12:616-622
    • (2000) J Magn Reson Imaging , vol.12 , pp. 616-622
    • Buecker, A.1    Neuerburg, J.M.2    Adam, G.B.3
  • 41
    • 0033934446 scopus 로고    scopus 로고
    • RF transmit power limit for the barewire loopless catheter antenna
    • Yeung CJ, Ataslar E. RF transmit power limit for the barewire loopless catheter antenna. J Magn Reson Imaging 2000;12:86-91
    • (2000) J Magn Reson Imaging , vol.12 , pp. 86-91
    • Yeung, C.J.1    Ataslar, E.2
  • 42
    • 0034070037 scopus 로고    scopus 로고
    • Reduction of resonant RF heating in intravascular catheters using coaxial chokes
    • Ladd ME, Quick HH. Reduction of resonant RF heating in intravascular catheters using coaxial chokes. Magn Reson Med 2000;43: 615-619
    • (2000) Magn Reson Med , vol.43 , pp. 615-619
    • Ladd, M.E.1    Quick, H.H.2
  • 44
    • 0029302084 scopus 로고
    • Percutaneous ablation therapy for hepatocellular carcinomas
    • D'Agostino HB, Solinas A. Percutaneous ablation therapy for hepatocellular carcinomas. AJR 1995;164:1165-1167
    • (1995) AJR , vol.164 , pp. 1165-1167
    • D'Agostino, H.B.1    Solinas, A.2
  • 45
    • 0031469805 scopus 로고    scopus 로고
    • Cryosurgical ablation of hepatic tumors
    • Crews KA, Kuhn JA, McCarty TM, et al. Cryosurgical ablation of hepatic tumors. Am J Surg 1997;114:614-618
    • (1997) Am J Surg , vol.114 , pp. 614-618
    • Crews, K.A.1    Kuhn, J.A.2    McCarty, T.M.3
  • 46
    • 0024390441 scopus 로고
    • Resection of hepatic metastases from colorectal cancer: Biologic perspectives
    • Steele G Jr, Ravikumar TS. Resection of hepatic metastases from colorectal cancer: biologic perspectives. Ann Surg 1989;210:127-138
    • (1989) Ann Surg , vol.210 , pp. 127-138
    • Steele G., Jr.1    Ravikumar, T.S.2
  • 49
    • 0031397655 scopus 로고    scopus 로고
    • Phase imaging on a 0.2T MR scanner: Applications to temperature monitoring during ablation procedures
    • Sinha S, Oshiro T, Sinha U, Lufkin R. Phase imaging on a 0.2T MR scanner: applications to temperature monitoring during ablation procedures. J Magn Reson Imaging 1997;7:918-928
    • (1997) J Magn Reson Imaging , vol.7 , pp. 918-928
    • Sinha, S.1    Oshiro, T.2    Sinha, U.3    Lufkin, R.4
  • 50
    • 0031823998 scopus 로고    scopus 로고
    • Monitoring and visualization for MR-guided laser ablations in an open MR system
    • Kettenbach J, Silverman SG, Hata N, et al. Monitoring and visualization for MR-guided laser ablations in an open MR system. J Magn Reson Imaging 1998;8:933-943
    • (1998) J Magn Reson Imaging , vol.8 , pp. 933-943
    • Kettenbach, J.1    Silverman, S.G.2    Hata, N.3
  • 51
    • 0001682236 scopus 로고    scopus 로고
    • Paramagnetic liposomes as thermosensitive probes for MRI in vitro feasibility studies
    • KnowledgeAccess International, Toronto
    • Fosshelm S, Ilyasov K, Wiggen U, et al. Paramagnetic liposomes as thermosensitive probes for MRI in vitro feasibility studies. In: Proceedings of the ISMRM. KnowledgeAccess International, Toronto, 1999:725
    • (1999) Proceedings of the ISMRM , pp. 725
    • Fosshelm, S.1    Ilyasov, K.2    Wiggen, U.3
  • 52
    • 10044229149 scopus 로고    scopus 로고
    • Spin transition molecular materials: Intelligent contrast agents for magnetic resonance thermometry
    • KnowledgeAccess International, Toronto
    • Bartholet A, Goudemant J, Laurent S, et al. Spin transition molecular materials: intelligent contrast agents for magnetic resonance thermometry. In: Proceedings of the ISMRM. KnowledgeAccess International, Toronto, 2000
    • (2000) Proceedings of the ISMRM
    • Bartholet, A.1    Goudemant, J.2    Laurent, S.3
  • 53
    • 0025732622 scopus 로고
    • Liver metastases: Results of percutaneous ethanol injection in 14 patients
    • Livraghi T, Vettori C, Lazzaroni S, et al. Liver metastases: results of percutaneous ethanol injection in 14 patients. Radiology 1991; 179:709-712
    • (1991) Radiology , vol.179 , pp. 709-712
    • Livraghi, T.1    Vettori, C.2    Lazzaroni, S.3
  • 54
    • 0031038472 scopus 로고    scopus 로고
    • MR appearance and spectral features of injected ethanol in the liver: Implication for fast MR-guided percutaneous ethanol injection therapy
    • Shinmoto H, Mulkern RV, Oshio SG, et al. MR appearance and spectral features of injected ethanol in the liver: implication for fast MR-guided percutaneous ethanol injection therapy. J Comput Assist Tomogr 1997;21:82-88
    • (1997) J Comput Assist Tomogr , vol.21 , pp. 82-88
    • Shinmoto, H.1    Mulkern, R.V.2    Oshio, S.G.3
  • 55
    • 0021056966 scopus 로고
    • Phototherapy of tumors
    • Bown SG. Phototherapy of tumors. World J Surg 1983;7:700-709
    • (1983) World J Surg , vol.7 , pp. 700-709
    • Bown, S.G.1
  • 56
    • 0024360231 scopus 로고
    • Interstitial laser hyperthermia: A new approach to local destruction of tumours
    • Steger AC, Lees WR, Walmsley K, Brown SG. Interstitial laser hyperthermia: a new approach to local destruction of tumours. BMJ 1989;299:362-365
    • (1989) BMJ , vol.299 , pp. 362-365
    • Steger, A.C.1    Lees, W.R.2    Walmsley, K.3    Brown, S.G.4
  • 57
    • 0029070217 scopus 로고
    • Malignant liver tumors treated with imaging guided laser induced thermotherapy, technique and prospective results
    • Vogl TJ, Müller PK, Hammerrstingl R, et al. Malignant liver tumors treated with imaging guided laser induced thermotherapy, technique and prospective results. Radiology 1995;196:257-265
    • (1995) Radiology , vol.196 , pp. 257-265
    • Vogl, T.J.1    Müller, P.K.2    Hammerrstingl, R.3
  • 58
    • 0027212010 scopus 로고
    • Liver tumor ablation by interstitial laser photocoagulation review of experimental and clinical studies
    • Amin Z, Bown SG, Lees WR. Liver tumor ablation by interstitial laser photocoagulation review of experimental and clinical studies. Semin Interv Radiol 1993;10:88-100
    • (1993) Semin Interv Radiol , vol.10 , pp. 88-100
    • Amin, Z.1    Bown, S.G.2    Lees, W.R.3
  • 59
    • 0027260607 scopus 로고
    • Local treatment of colorectal liver metastases: A comparison of interstitial laser photocoagulation (ILP) and percutaneous alcohol injection (PAI)
    • Amin Z, Bown SG, Lees WR. Local treatment of colorectal liver metastases: a comparison of interstitial laser photocoagulation (ILP) and percutaneous alcohol injection (PAI). Clin Radiol 1993;48: 166-171
    • (1993) Clin Radiol , vol.48 , pp. 166-171
    • Amin, Z.1    Bown, S.G.2    Lees, W.R.3
  • 60
    • 0027213517 scopus 로고
    • Interstitial laser photocoagulation: Evaluation of a 1320nm Nd-Yag and an 805nm diode laser: The significance of charring the fibre tip
    • Amin Z, Buonaccorsi G, Mills T, et al. Interstitial laser photocoagulation: evaluation of a 1320nm Nd-Yag and an 805nm diode laser: the significance of charring the fibre tip. Lasers Med Sci 1993;8:113-120
    • (1993) Lasers Med Sci , vol.8 , pp. 113-120
    • Amin, Z.1    Buonaccorsi, G.2    Mills, T.3
  • 61
    • 0027159220 scopus 로고
    • Hepatic metastases: Interstitial laser photocoagulation with real-time US monitoring and dynamic CT evaluation treatment
    • Amin Z, Donald J, Masters A, et al. Hepatic metastases: interstitial laser photocoagulation with real-time US monitoring and dynamic CT evaluation treatment. Radiology 1993;187:339-347
    • (1993) Radiology , vol.187 , pp. 339-347
    • Amin, Z.1    Donald, J.2    Masters, A.3
  • 62
    • 0032055869 scopus 로고    scopus 로고
    • Cryosurgery as a treatment for advanced stage hepatocellular carcinoma
    • Wong WS, Patel SC, Cruz FS, et al. Cryosurgery as a treatment for advanced stage hepatocellular carcinoma. Cancer 1998;82:1268-1278
    • (1998) Cancer , vol.82 , pp. 1268-1278
    • Wong, W.S.1    Patel, S.C.2    Cruz, F.S.3
  • 63
    • 0031910092 scopus 로고    scopus 로고
    • Intraoperative monitoring and postoperative imaging of hepatic cryosurgery
    • Brewer WH, Austin RS, Capps GW, et al. Intraoperative monitoring and postoperative imaging of hepatic cryosurgery. Semin Surg Oncol 1998;14:129-155
    • (1998) Semin Surg Oncol , vol.14 , pp. 129-155
    • Brewer, W.H.1    Austin, R.S.2    Capps, G.W.3
  • 64
    • 0031960682 scopus 로고    scopus 로고
    • Hepatic cryoablation: US monitoring of extent of necrosis in normal pig liver
    • Weber SM, Lee FT, Warner TF, et al. Hepatic cryoablation: US monitoring of extent of necrosis in normal pig liver. Radiology 1998;207:73-77
    • (1998) Radiology , vol.207 , pp. 73-77
    • Weber, S.M.1    Lee, F.T.2    Warner, T.F.3
  • 65
    • 1842409596 scopus 로고    scopus 로고
    • Hepatic cryosurgery with intraoperative US guidance
    • Lee FT, Mahve DM, Chosy SG et al. Hepatic cryosurgery with intraoperative US guidance. Radiology 1997;202:624-632
    • (1997) Radiology , vol.202 , pp. 624-632
    • Lee, F.T.1    Mahve, D.M.2    Chosy, S.G.3
  • 66
    • 0028337304 scopus 로고
    • Cryoablation in hepatic surgery
    • Steele G Jr. Cryoablation in hepatic surgery. Semin Liver Dis 1994;14:120-125
    • (1994) Semin Liver Dis , vol.14 , pp. 120-125
    • Steele G., Jr.1
  • 68
    • 0027664848 scopus 로고
    • Monitoring of laser and freezing-induced ablation in the liver with T1-weighted MR imaging
    • Matsumoto R, Oshio K, Jolesz FA. Monitoring of laser and freezing-induced ablation in the liver with T1-weighted MR imaging. J Magn Reson Imaging 1993;3:770-776
    • (1993) J Magn Reson Imaging , vol.3 , pp. 770-776
    • Matsumoto, R.1    Oshio, K.2    Jolesz, F.A.3
  • 69
    • 0035133730 scopus 로고    scopus 로고
    • Percutaneous tumor ablation with magnetic resonance imaging guidance
    • Shingleton BW, Sewell PE. Percutaneous tumor ablation with magnetic resonance imaging guidance. J Urol 2001;165:773-776
    • (2001) J Urol , vol.165 , pp. 773-776
    • Shingleton, B.W.1    Sewell, P.E.2
  • 70
    • 0033979118 scopus 로고    scopus 로고
    • Thermal ablation therapy for focal malignancy: A unified approach to underlying principles, techniques, and diagnostic imaging guidance
    • Goldberg SN, Gazelle GS, Mueller PR. Thermal ablation therapy for focal malignancy: a unified approach to underlying principles, techniques, and diagnostic imaging guidance. AJR 2000;174:323-331
    • (2000) AJR , vol.174 , pp. 323-331
    • Goldberg, S.N.1    Gazelle, G.S.2    Mueller, P.R.3
  • 71
    • 0029294873 scopus 로고
    • Tissue ablation with radiofrequency: Effect of probe size, gauge, duration, and temperature on lesion volume
    • Goldberg S, Gazelle G, Dawson S, et al. Tissue ablation with radiofrequency: effect of probe size, gauge, duration, and temperature on lesion volume. Acad Radiol 1995;2:399-404
    • (1995) Acad Radiol , vol.2 , pp. 399-404
    • Goldberg, S.1    Gazelle, G.2    Dawson, S.3
  • 72
    • 0027430278 scopus 로고
    • Percutaneous ultrasound-guided radiofrequency electrocautery for the treatment of small hepatocellular carcinoma
    • Rossi S, Fornari F, Buscarini L. Percutaneous ultrasound-guided radiofrequency electrocautery for the treatment of small hepatocellular carcinoma. J Interv Radiol 1993;8:97-103
    • (1993) J Interv Radiol , vol.8 , pp. 97-103
    • Rossi, S.1    Fornari, F.2    Buscarini, L.3
  • 73
    • 0031030127 scopus 로고    scopus 로고
    • Saline-enhanced radiofrequency tissue ablation in the treatment of liver metastases
    • Livraghi T, Goldberg S, Monti F, et al. Saline-enhanced radiofrequency tissue ablation in the treatment of liver metastases. Radiology 1997;202:205-210
    • (1997) Radiology , vol.202 , pp. 205-210
    • Livraghi, T.1    Goldberg, S.2    Monti, F.3
  • 74
    • 0029294873 scopus 로고
    • Tissue ablation with radiofrequency: Effect of probe size, gauge, and temperature on lesion volume
    • Goldberg S, Gazelle S, Dawson S, et al. Tissue ablation with radiofrequency: effect of probe size, gauge, and temperature on lesion volume. Acad Radiol 1995;2:399-404
    • (1995) Acad Radiol , vol.2 , pp. 399-404
    • Goldberg, S.1    Gazelle, S.2    Dawson, S.3
  • 75
    • 0029298735 scopus 로고
    • MR monitoring of focused ultrasonic surgery of renal cortex: Experimental and simulation studies
    • Hynynen K, Damainou CA, Colucci Y, et al. MR monitoring of focused ultrasonic surgery of renal cortex: experimental and simulation studies. J Magn Reson Imaging 1995;5:259-266
    • (1995) J Magn Reson Imaging , vol.5 , pp. 259-266
    • Hynynen, K.1    Damainou, C.A.2    Colucci, Y.3
  • 76
    • 0026407998 scopus 로고
    • High-intensity focused ultrasound in the treatment of experimental liver cancer
    • Yang R, Reilly CR, Rescoria FJ, et al. High-intensity focused ultrasound in the treatment of experimental liver cancer. Arch Surg 1991;126:1002-1010
    • (1991) Arch Surg , vol.126 , pp. 1002-1010
    • Yang, R.1    Reilly, C.R.2    Rescoria, F.J.3
  • 77
    • 0026673145 scopus 로고
    • Extracorporeal liver ablation using sonography-guided high-intensity focused ultrasound
    • Yang R, Sanghvi NT, Rescorla FJ, et al. Extracorporeal liver ablation using sonography-guided high-intensity focused ultrasound. Invest Radiol 1992;27:796-803
    • (1992) Invest Radiol , vol.27 , pp. 796-803
    • Yang, R.1    Sanghvi, N.T.2    Rescorla, F.J.3
  • 78
    • 0035352897 scopus 로고    scopus 로고
    • Pathological study of extracorporeally ablated hepatocellular carcinoma with high-intensity focused ultrasound
    • Wu F, Wang Z, Chen W. Pathological study of extracorporeally ablated hepatocellular carcinoma with high-intensity focused ultrasound. Zhonghua Zhong Liu Za Zhi 2001;23:237-239
    • (2001) Zhonghua Zhong Liu Za Zhi , vol.23 , pp. 237-239
    • Wu, F.1    Wang, Z.2    Chen, W.3
  • 82
    • 0030870878 scopus 로고    scopus 로고
    • An adjustment to the 1997 estimate for new prostate cancer cases
    • Wingo PA, Landio S, Reis LAG. An adjustment to the 1997 estimate for new prostate cancer cases. CA Cancer J Clin 1997;47: 239-242
    • (1997) CA Cancer J Clin , vol.47 , pp. 239-242
    • Wingo, P.A.1    Landio, S.2    Reis, L.A.G.3
  • 83
    • 0032518601 scopus 로고    scopus 로고
    • A survey of current clinical practice of permanent prostate brachytherapy in the United States
    • Prestidge BR, Prete JJ, Bucholtz TA, et al. A survey of current clinical practice of permanent prostate brachytherapy in the United States. Int J Radiat Oncol Biol Phys 1998;40:461-465
    • (1998) Int J Radiat Oncol Biol Phys , vol.40 , pp. 461-465
    • Prestidge, B.R.1    Prete, J.J.2    Bucholtz, T.A.3
  • 84
    • 0031012183 scopus 로고    scopus 로고
    • Staging prostate cancer with MR imaging: A combined radiologist-computer system
    • Seltzer SE, Getty DJ, Tempany CMC, et al. Staging prostate cancer with MR imaging: a combined radiologist-computer system. Radiology 1997;202:219-226
    • (1997) Radiology , vol.202 , pp. 219-226
    • Seltzer, S.E.1    Getty, D.J.2    Tempany, C.M.C.3
  • 85
    • 0031724260 scopus 로고    scopus 로고
    • Real time magnetic resonance image guided interstitial brachytherapy in the treatment of selected patients with clinically localized prostate cancer
    • D'Amico AV, Cormack R, Tempany CMC, et al. Real time magnetic resonance image guided interstitial brachytherapy in the treatment of selected patients with clinically localized prostate cancer. Int J Radiat Oncol Biol Phys 1998;42:507-515
    • (1998) Int J Radiat Oncol Biol Phys , vol.42 , pp. 507-515
    • D'Amico, A.V.1    Cormack, R.2    Tempany, C.M.C.3
  • 86
    • 0033919397 scopus 로고    scopus 로고
    • Real-time magnetic resonance imaging-guided brachytherapy in the treatment of selected patients with clinically localized prostate cancer
    • D'Amico A, Cormack R, Kumar S, Tempany CM. Real-time magnetic resonance imaging-guided brachytherapy in the treatment of selected patients with clinically localized prostate cancer. J Endourol 2000;14:367-370
    • (2000) J Endourol , vol.14 , pp. 367-370
    • D'Amico, A.1    Cormack, R.2    Kumar, S.3    Tempany, C.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.