Volumn 31, Issue 5, 2003, Pages 929-933

Probe measurement of residual plasma of a magnetically confined high-current vacuum arc

Author keywords

Electrostatic probe; Probe measurement; Residual plasma; Vacuum arc

Indexed keywords

ELECTRIC ARCS; ELECTROSTATICS; MAGNETIC FIELD EFFECTS; PLASMA DENSITY; PLASMA PROBES; VACUUM APPLICATIONS;

EID: 0242292097     PISSN: 00933813     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPS.2003.818424     Document Type: Article
Times cited : (34)

References (10)
  • 1
    • 0020497257 scopus 로고
    • The high-current vacuum arc in an axial magnetic field: An experimental investigation
    • H. Schellekens, "The high-current vacuum arc in an axial magnetic field: An experimental investigation," J. Appl. Phys., vol. 54, no. 1, pp. 144-149, 1983.
    • (1983) J. Appl. Phys. , vol.54 , Issue.1 , pp. 144-149
    • Schellekens, H.1
  • 2
    • 0010849290 scopus 로고
    • Theoretical and experimental study of a high-current vacuum arc in a uniform axial magnetic field
    • Jan
    • O. Morimiya, "Theoretical and experimental study of a high-current vacuum arc in a uniform axial magnetic field," J. Appl. Phys., vol. 71, no. 1, pp. 101-107, Jan. 1992.
    • (1992) J. Appl. Phys. , vol.71 , Issue.1 , pp. 101-107
    • Morimiya, O.1
  • 3
    • 0000932859 scopus 로고
    • The vacuum switch
    • M. R. Reece, "The vacuum switch," Proc. IEEE, vol. 51, pp. 803-811, 1963.
    • (1963) Proc. IEEE , vol.51 , pp. 803-811
    • Reece, M.R.1
  • 4
    • 0008967305 scopus 로고
    • Decay of residual plasma in a vacuum gap after forced extinction of a 250-ampere arc
    • Dec
    • G. A. Farrall, "Decay of residual plasma in a vacuum gap after forced extinction of a 250-ampere arc," Proc. IEEE, vol. 56, pp. 2137-2145, Dec. 1968.
    • (1968) Proc. IEEE , vol.56 , pp. 2137-2145
    • Farrall, G.A.1
  • 5
    • 0021475741 scopus 로고
    • Post arc current after high-current interruption in vacuum
    • S. Yanabu et al., "Post arc current after high-current interruption in vacuum," IEEE Trans. Elect. Insulation, vol. EI-20, no. 4, pp. 187-192, 1985.
    • (1985) IEEE Trans. Elect. Insulation , vol.EI-20 , Issue.4 , pp. 187-192
    • Yanabu, S.1
  • 6
    • 36849100211 scopus 로고
    • Analysis of the electrode products emitted by dc arcs in a vacuum ambient
    • Apr
    • W. D. Davis and H. C. Miller, "Analysis of the electrode products emitted by dc arcs in a vacuum ambient," J. Appl. Phys., vol. 40, pp. 2212-2221, Apr. 1969.
    • (1969) J. Appl. Phys. , vol.40 , pp. 2212-2221
    • Davis, W.D.1    Miller, H.C.2
  • 7
    • 0033353250 scopus 로고    scopus 로고
    • Influence of interrupted current amplitude on the post-arc current and gap recovery after current zero - Experimental and simulation
    • Aug
    • E. F. Huber, K. D. Weltmann, and K. Froehlich, "Influence of interrupted current amplitude on the post-arc current and gap recovery after current zero - Experimental and simulation," IEEE Trans. Plasma Sci., vol. 27, pp. 930-937, Aug. 1999.
    • (1999) IEEE Trans. Plasma Sci. , vol.27 , pp. 930-937
    • Huber, E.F.1    Weltmann, K.D.2    Froehlich, K.3
  • 8
    • 84988751997 scopus 로고
    • R. H. Huddlestone, Ed.; New York: Academic; ch. 4
    • R. H. Huddlestone, Ed., Plasma Diagnostic Techniques. New York: Academic 1965, ch. 4.
    • (1965) Plasma Diagnostic Techniques
  • 10
    • 0015331546 scopus 로고
    • Measurement on particle fluxes from dc vacuum arcs subjected to artificial current zeroes
    • May
    • H. C. Miller, "Measurement on particle fluxes from dc vacuum arcs subjected to artificial current zeroes," J. Appl. Phys., vol. 43, pp. 2175-2181, May 1972.
    • (1972) J. Appl. Phys. , vol.43 , pp. 2175-2181
    • Miller, H.C.1