1
-
-
0031093586
-
Repairing holes in the head: A history of cranioplasty
-
Sanan A., Haines S.J. Repairing holes in the head a history of cranioplasty . Neurosurgery. 40:1997;588-601.
-
(1997)
Neurosurgery
, vol.40
, pp. 588-601
-
-
Sanan, A.1
Haines, S.J.2
-
2
-
-
0019631341
-
Cranioplasty of the difficult frontal region
-
Firtell D.N., Grisius R.J. Cranioplasty of the difficult frontal region. J Prosthet Dent. 46:1981;425-429.
-
(1981)
J Prosthet Dent
, vol.46
, pp. 425-429
-
-
Firtell, D.N.1
Grisius, R.J.2
-
3
-
-
0000625677
-
Form-fitting plastic cranioplasty
-
Spence W.T. Form-fitting plastic cranioplasty. J Neurosurg. 11:1954;219-225.
-
(1954)
J Neurosurg
, vol.11
, pp. 219-225
-
-
Spence, W.T.1
-
5
-
-
0021867643
-
Preformed polymethylmethacrylate cranioplasties: Report of 45 cases
-
van Gool A.V. Preformed polymethylmethacrylate cranioplasties report of 45 cases . J Maxillofac Surg. 13:1985;2-8.
-
(1985)
J Maxillofac Surg
, vol.13
, pp. 2-8
-
-
Van Gool, A.V.1
-
6
-
-
0026889348
-
Alloplastic cranial implants made from computed tomographic scan-generated casts
-
van Putten M.C. Jr, Yamada S. Alloplastic cranial implants made from computed tomographic scan-generated casts. J Prosthet Dent. 68:1992;103-108.
-
(1992)
J Prosthet Dent
, vol.68
, pp. 103-108
-
-
Van Putten M.C., Jr.1
Yamada, S.2
-
7
-
-
0017649653
-
A pre-formed methyl methacrylate cranioplasty
-
Cooper P.R., Schechter B., Jacobs G.B., Rubin R.C., Wille R.L. A pre-formed methyl methacrylate cranioplasty. Surg Neurol. 8:1977;219-221.
-
(1977)
Surg Neurol
, vol.8
, pp. 219-221
-
-
Cooper, P.R.1
Schechter, B.2
Jacobs, G.B.3
Rubin, R.C.4
Wille, R.L.5
-
10
-
-
0018182575
-
Cranioplasty made easier
-
Genest A.S. Cranioplasty made easier. Surg Neurol. 10:1978;255-257.
-
(1978)
Surg Neurol
, vol.10
, pp. 255-257
-
-
Genest, A.S.1
-
12
-
-
0004057280
-
Restorative dental materials
-
St. Louis: Elsevier Science. p. 657-8
-
Craig R.G., Powers J.M. Restorative dental materials. 11th ed :2002;Elsevier Science, St. Louis. p. 657-8.
-
(2002)
11th ed
-
-
Craig, R.G.1
Powers, J.M.2
-
14
-
-
0026232005
-
Tissue compatibility of methylmethacrylate in cranial prostheses: A preliminary investigation
-
Gary J.J., Mitchell D.L., Steifel S.M., Hale M.L. Tissue compatibility of methylmethacrylate in cranial prostheses a preliminary investigation . J Prosthet Dent. 66:1991;530-536.
-
(1991)
J Prosthet Dent
, vol.66
, pp. 530-536
-
-
Gary, J.J.1
Mitchell, D.L.2
Steifel, S.M.3
Hale, M.L.4
-
17
-
-
0014830794
-
Fabrication of an alloplastic cranioimplant
-
Brown K.E. Fabrication of an alloplastic cranioimplant. J Prosthet Dent. 24:1970;213-224.
-
(1970)
J Prosthet Dent
, vol.24
, pp. 213-224
-
-
Brown, K.E.1
-
19
-
-
0015043866
-
A radiographic grid for contouring cranial prostheses
-
Firtell D.N., Moore D.J., Bartlett S.O. A radiographic grid for contouring cranial prostheses. J Prosthet Dent. 25:1971;439-445.
-
(1971)
J Prosthet Dent
, vol.25
, pp. 439-445
-
-
Firtell, D.N.1
Moore, D.J.2
Bartlett, S.O.3
-
20
-
-
0021487470
-
Cranial implant modification
-
Martin J.W., Ganz S.D., King G.E., Jacob R.F., Kramer D.C. Cranial implant modification. J Prosthet Dent. 52:1984;414-416.
-
(1984)
J Prosthet Dent
, vol.52
, pp. 414-416
-
-
Martin, J.W.1
Ganz, S.D.2
King, G.E.3
Jacob, R.F.4
Kramer, D.C.5
-
21
-
-
0016646495
-
Cranial implant problems
-
Sabin H. Cranial implant problems. J Prosthet Dent. 34:1975;659-665.
-
(1975)
J Prosthet Dent
, vol.34
, pp. 659-665
-
-
Sabin, H.1
-
22
-
-
0023799440
-
Fabrication of an alloplastic implant for the cranial defect
-
Aquilino S.A., Jordan R.D., White J.T. Fabrication of an alloplastic implant for the cranial defect. J Prosthet Dent. 59:1988;68-71.
-
(1988)
J Prosthet Dent
, vol.59
, pp. 68-71
-
-
Aquilino, S.A.1
Jordan, R.D.2
White, J.T.3
-
23
-
-
0014298669
-
Cranioplasty prostheses for replacement of cranial bone
-
Schupper N. Cranioplasty prostheses for replacement of cranial bone. J Prosthet Dent. 19:1968;594-597.
-
(1968)
J Prosthet Dent
, vol.19
, pp. 594-597
-
-
Schupper, N.1
-
24
-
-
0022721110
-
Comparison of computer-based fabrication of alloplastic cranial implants with conventional techniques
-
Mankovich N.J., Curtis D.A., Kagawa T., Beumer J. 3rd. Comparison of computer-based fabrication of alloplastic cranial implants with conventional techniques. J Prosthet Dent. 55:1986;606-609.
-
(1986)
J Prosthet Dent
, vol.55
, pp. 606-609
-
-
Mankovich, N.J.1
Curtis, D.A.2
Kagawa, T.3
Beumer J. III4
-
25
-
-
0026516508
-
Stereolithographic models for surgical planning: A preliminary report
-
Stoker N.G., Mankovich N.J., Valentino D. Stereolithographic models for surgical planning a preliminary report . J Oral Maxillofac Surg. 50:1992;466-471.
-
(1992)
J Oral Maxillofac Surg
, vol.50
, pp. 466-471
-
-
Stoker, N.G.1
Mankovich, N.J.2
Valentino, D.3
-
26
-
-
0033998729
-
Custom cranioplasty using stereolithography and acrylic
-
D'Urso P.S., Earwaker W.J., Barker T.M., Redmond M.J., Thompson R.G., Effeney D.J., et al. Custom cranioplasty using stereolithography and acrylic. Br J Plast Surg. 53:2000;200-204.
-
(2000)
Br J Plast Surg
, vol.53
, pp. 200-204
-
-
D'Urso, P.S.1
Earwaker, W.J.2
Barker, T.M.3
Redmond, M.J.4
Thompson, R.G.5
Effeney, D.J.6
-
27
-
-
0028110104
-
Surgical planning using three-dimensional imaging and computer modeling
-
Mankovich N.J., Samson D., Pratt W., Lew D., Beumer J. 3rd. Surgical planning using three-dimensional imaging and computer modeling. Otolaryngol Clin North Am. 27:1994;875-889.
-
(1994)
Otolaryngol Clin North Am
, vol.27
, pp. 875-889
-
-
Mankovich, N.J.1
Samson, D.2
Pratt, W.3
Lew, D.4
Beumer J. III5
-
28
-
-
0029053529
-
Reconstruction of craniofacial bone defects with individual alloplastic implants based on CAD/CAM-manipulated CT-data
-
Eufinger H., Wehmoller M., Machtens E., Heuser L., Harders A., Kruse D. Reconstruction of craniofacial bone defects with individual alloplastic implants based on CAD/CAM-manipulated CT-data. J Craniomaxillofac Surg. 23:1995;175-181.
-
(1995)
J Craniomaxillofac Surg
, vol.23
, pp. 175-181
-
-
Eufinger, H.1
Wehmoller, M.2
Machtens, E.3
Heuser, L.4
Harders, A.5
Kruse, D.6
-
29
-
-
0029242194
-
Stereolithography in oral and maxillofacial operation planning
-
Bill J.S., Reuther J.F., Dittman W., Kubler N., Meier J.L., Pistner H., et al. Stereolithography in oral and maxillofacial operation planning. Int J Oral Maxillofac Surg. 24:1995;98-103.
-
(1995)
Int J Oral Maxillofac Surg
, vol.24
, pp. 98-103
-
-
Bill, J.S.1
Reuther, J.F.2
Dittman, W.3
Kubler, N.4
Meier, J.L.5
Pistner, H.6
-
30
-
-
0032883597
-
An opinion survey of reported benefits from the use of stereolithographic models
-
Erickson D.M., Chance D., Schmitt S., Mathis J. An opinion survey of reported benefits from the use of stereolithographic models. J Oral Maxillofac Surg. 57:1999;1040-1043.
-
(1999)
J Oral Maxillofac Surg
, vol.57
, pp. 1040-1043
-
-
Erickson, D.M.1
Chance, D.2
Schmitt, S.3
Mathis, J.4
-
31
-
-
0035094757
-
Mechanical properties and cell cultural response of polycaprolactone scaffolds designed and fabricated via fused deposition modeling
-
Hutmacher D.W., Schantz T., Zein I., Ng K.W., Teoh S.H., Tan K.C. Mechanical properties and cell cultural response of polycaprolactone scaffolds designed and fabricated via fused deposition modeling. J Biomed Mater Res. 55:2001;203-216.
-
(2001)
J Biomed Mater Res
, vol.55
, pp. 203-216
-
-
Hutmacher, D.W.1
Schantz, T.2
Zein, I.3
Ng, K.W.4
Teoh, S.H.5
Tan, K.C.6
-
32
-
-
0028318225
-
Accuracy of stereolithographic models of human anatomy
-
Barker T.M., Earwaker W.J., Lisle D.A. Accuracy of stereolithographic models of human anatomy. Australas Radiol. 38:1994;106-111.
-
(1994)
Australas Radiol
, vol.38
, pp. 106-111
-
-
Barker, T.M.1
Earwaker, W.J.2
Lisle, D.A.3
-
33
-
-
0036005914
-
Analysis of errors in medical rapid prototyping models
-
Choi J.Y., Choi J.H., Kim N.K., Kim Y., Lee J.K., Kim M.K., et al. Analysis of errors in medical rapid prototyping models. Int J Oral Maxillofac Surg. 31:2002;23-32.
-
(2002)
Int J Oral Maxillofac Surg
, vol.31
, pp. 23-32
-
-
Choi, J.Y.1
Choi, J.H.2
Kim, N.K.3
Kim, Y.4
Lee, J.K.5
Kim, M.K.6
-
34
-
-
0026182256
-
The effect of steam autoclave sterilization on methyl methacrylate cranial implant materials
-
Jacob R.F., Collard S.M. The effect of steam autoclave sterilization on methyl methacrylate cranial implant materials. Int J Prosthodont. 4:1991;345-352.
-
(1991)
Int J Prosthodont
, vol.4
, pp. 345-352
-
-
Jacob, R.F.1
Collard, S.M.2
|