메뉴 건너뛰기




Volumn 4, Issue 3-4, 2003, Pages 405-420

3-D numerical analysis of the stress state caused by short-term loading of a fixed dental implant containing a "PDL-Like" nonlinear elastic internal layer

Author keywords

Nonlinear finite element analysis; Osseointegrated dental implants; Periodontal ligament

Indexed keywords

BONE; BOUNDARY CONDITIONS; COMPUTER SIMULATION; FINITE ELEMENT METHOD; LIGAMENTS;

EID: 0242285527     PISSN: 15261492     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (6)

References (30)
  • 1
    • 0026187621 scopus 로고
    • Determination of stress levels and profiles in the periodontal ligament by means of an improved three-dimensional finite element model for various types of orthodontic and natural force systems
    • Andersen K.L., Mortensen H.T., Pedersen E.H., Melsen B. (1991), Determination of stress levels and profiles in the periodontal ligament by means of an improved three-dimensional finite element model for various types of orthodontic and natural force systems. J Biomed Engineering, 13, 293-303.
    • (1991) J Biomed Engineering , vol.13 , pp. 293-303
    • Andersen, K.L.1    Mortensen, H.T.2    Pedersen, E.H.3    Melsen, B.4
  • 2
    • 0026740505 scopus 로고
    • Biomechanical factors affecting the bone-dental implant interface
    • Brunski J.B. (1992), Biomechanical Factors Affecting the Bone-Dental Implant Interface. Clinical Materials, 10, 153-201.
    • (1992) Clinical Materials , vol.10 , pp. 153-201
    • Brunski, J.B.1
  • 3
    • 0025435481 scopus 로고
    • Titanium implants with a true periodontal ligament: An alternative to osseointegrated implants?
    • Buser D., Warrer K., Karring T., Stich H. (1990), Titanium Implants with a True Periodontal Ligament: An Alternative to Osseointegrated Implants? Int J Oral Maxillof Implants 5, 113-116.
    • (1990) Int J Oral Maxillof Implants , vol.5 , pp. 113-116
    • Buser, D.1    Warrer, K.2    Karring, T.3    Stich, H.4
  • 4
    • 0029436116 scopus 로고
    • Comparative analysis of bone stresses and strains in the Intoss dental implant with and without a flexible internal post
    • Clift S.E., Fisher J., Edwards B.N. (1995), Comparative analysis of bone stresses and strains in the Intoss dental implant with and without a flexible internal post. Proc Instn Mech Engineers, 209, 139-147.
    • (1995) Proc Instn Mech Engineers , vol.209 , pp. 139-147
    • Clift, S.E.1    Fisher, J.2    Edwards, B.N.3
  • 5
    • 0242380175 scopus 로고    scopus 로고
    • Finite element analysis of the jaw-teeth/dental implant system: A note about geometrical and material modeling
    • Corradi L., Genna F. (2003), Finite Element analysis of the jaw-teeth/dental implant system: a note about geometrical and material modeling. CMES: Computer Modeling in Engineering & Sciences, vol. 4, no. 3&4, pp. 381-396.
    • (2003) CMES: Computer Modeling in Engineering & Sciences , vol.4 , Issue.3-4 , pp. 381-396
    • Corradi, L.1    Genna, F.2
  • 6
    • 0036773508 scopus 로고    scopus 로고
    • An interface model for the periodontal ligament
    • Gei M., Genna F., Bigoni D. (2002), An interface model for the periodontal ligament. ASME J Biomechanical Engineering, 124(5), 538-546.
    • (2002) ASME J Biomechanical Engineering , vol.124 , Issue.5 , pp. 538-546
    • Gei, M.1    Genna, F.2    Bigoni, D.3
  • 7
    • 0242315518 scopus 로고    scopus 로고
    • On the effects of cyclic transversal forces on osteointegrated dental implants: Experimental and finite element, shakedown analyses
    • Genna F. (2003), On the effects of cyclic transversal forces on osteointegrated dental implants: experimental and Finite Element, shakedown analyses. Comp Meth Biomechanics and Biomechanical Engineering, 6(2), 141-152.
    • (2003) Comp Meth Biomechanics and Biomechanical Engineering , vol.6 , Issue.2 , pp. 141-152
    • Genna, F.1
  • 9
    • 0027031544 scopus 로고
    • Comparison of stress transmission in the IMZ implant system with polyoxymethylene or titanium intramobile element: A finite element stress analysis
    • Holmes D.C., Grigsby W.R., Goel V.K., Keller J.C. (1992), Comparison of Stress Transmission in the IMZ Implant System With Polyoxymethylene or Titanium Intramobile Element: A Finite Element Stress Analysis. Int J Oral Maxillof Implants, 7, 450-458.
    • (1992) Int J Oral Maxillof Implants , vol.7 , pp. 450-458
    • Holmes, D.C.1    Grigsby, W.R.2    Goel, V.K.3    Keller, J.C.4
  • 10
    • 0024201743 scopus 로고
    • The ability of currently available stress-breaking elements for osseointegrated implants to imitate natural tooth mobility
    • Lill W., Matejka M., Rambousek K., Watzek G. (1988), The Ability of Currently Available Stress-Breaking Elements for Osseointegrated Implants to Imitate Natural Tooth Mobility. Int J Oral Maxillof Implants, 3, 281-286.
    • (1988) Int J Oral Maxillof Implants , vol.3 , pp. 281-286
    • Lill, W.1    Matejka, M.2    Rambousek, K.3    Watzek, G.4
  • 11
    • 0032187037 scopus 로고    scopus 로고
    • A finite element bibliography for biomechanics (1987-1997)
    • Mackerle J. (1998), A finite element bibliography for biomechanics (1987-1997). Appl Mech Reviews, 51, 587-634.
    • (1998) Appl Mech Reviews , vol.51 , pp. 587-634
    • Mackerle, J.1
  • 12
    • 0003709048 scopus 로고
    • Introduction to the mechanics of a continuous medium
    • Prentice-hall, Inc., Englewood Cliffs, New Jersey, US
    • Malvern L.E. (1969), Introduction to the mechanics of a continuous medium. Prentice-Hall, Inc., Englewood Cliffs, New Jersey, US.
    • (1969)
    • Malvern, L.E.1
  • 15
    • 72849163842 scopus 로고
    • Measurement of physiological mobility of individual teeth in an axial direction
    • Parfitt G.J. (1960), Measurement of Physiological Mobility of Individual Teeth in an Axial Direction. J Dental Research, 39(3), 608-618.
    • (1960) J Dental Research , vol.39 , Issue.3 , pp. 608-618
    • Parfitt, G.J.1
  • 16
    • 4243874496 scopus 로고    scopus 로고
    • Development of a micromechanically based interface law for the periodontal ligament
    • Internal Report, Landau Network-Centro Volta Fellowship, Department of Civil Engineering, University of Brescia, Italy
    • Perelmuter M.N. (2001), Development of a micromechanically based interface law for the periodontal ligament. Internal Report, Landau Network-Centro Volta Fellowship, Department of Civil Engineering, University of Brescia, Italy.
    • (2001)
    • Perelmuter, M.N.1
  • 17
    • 0034333759 scopus 로고    scopus 로고
    • Experimental and computational approach for the evaluation of the biomechanical effects of dental bridge misfit
    • Pietrabissa R., Contro R., Quaglini V., Soncini M., Gionso L., Simion M. (2000), Experimental and computational approach for the evaluation of the biomechanical effects of dental bridge misfit. J Biomechanics, 33, 1489-1495.
    • (2000) J Biomechanics , vol.33 , pp. 1489-1495
    • Pietrabissa, R.1    Contro, R.2    Quaglini, V.3    Soncini, M.4    Gionso, L.5    Simion, M.6
  • 18
    • 0242283757 scopus 로고    scopus 로고
    • PhD Thesis. LMAF-DGM-EPFL, Lausanne, Switzerland
    • Pietrzak G. (1997), PhD Thesis. LMAF-DGM-EPFL, Lausanne, Switzerland.
    • (1997)
    • Pietrzak, G.1
  • 20
    • 0003668176 scopus 로고    scopus 로고
    • Mechanical characterization and modeling of the periodontal ligament
    • PhD Thesis, University of Trento, Italy
    • Pini M. (1999), Mechanical Characterization and Modeling of the Periodontal Ligament. PhD Thesis, University of Trento, Italy.
    • (1999)
    • Pini, M.1
  • 22
    • 0020450497 scopus 로고
    • Tensile behavior of the periodontal ligament
    • Ralph W.J. (1982), Tensile behavior of the periodontal ligament. J Period Research, 17, 423-426.
    • (1982) J Period Research , vol.17 , pp. 423-426
    • Ralph, W.J.1
  • 23
    • 0038774688 scopus 로고    scopus 로고
    • Risk factors in implant dentistry: Simplified clinical analysis for practical treatment
    • Quintessence Pub. Co.
    • Rangert B., Renouard F. (1999), Risk Factors in Implant Dentistry: Simplified Clinical Analysis for Practical Treatment. Quintessence Pub. Co.
    • (1999)
    • Rangert, B.1    Renouard, F.2
  • 24
    • 0031193388 scopus 로고    scopus 로고
    • Elastic modulus of the periodontal ligament
    • Rees J.S., Jacobsen P.H. (1997), Elastic modulus of the periodontal ligament. Biomaterials, 10, 995-999.
    • (1997) Biomaterials , vol.10 , pp. 995-999
    • Rees, J.S.1    Jacobsen, P.H.2
  • 25
    • 0025355935 scopus 로고
    • Dental implant abutment resembling the two-phase tooth mobility
    • Richter E-J., Orschall B., Jovanovic S.A. (1990), Dental implant abutment resembling the two-phase tooth mobility. J Biomechanics, 23(4), 297-306.
    • (1990) J Biomechanics , vol.23 , Issue.4 , pp. 297-306
    • Richter, E.-J.1    Orschall, B.2    Jovanovic, S.A.3
  • 27
    • 0029302999 scopus 로고
    • Nonlinear contact analysis of preload in dental implant screws
    • Sakaguchi R.L., Borgersen S.E. (1995), Nonlinear Contact Analysis of Preload in Dental Implant Screws. Int J Oral Maxillof Implants, 10(3), 295-302.
    • (1995) Int J Oral Maxillof Implants , vol.10 , Issue.3 , pp. 295-302
    • Sakaguchi, R.L.1    Borgersen, S.E.2
  • 28
    • 0022440426 scopus 로고
    • On material representation and constitutive branching in finite compressible elasticity
    • Storåkers B. (1986), On material representation and constitutive branching in finite compressible elasticity. J Mech Phys Solids, 34, 125-145.
    • (1986) J Mech Phys Solids , vol.34 , pp. 125-145
    • Storåkers, B.1
  • 30
    • 0021751002 scopus 로고
    • Orthodontic tooth movement analysed by the finite element method
    • Williams K.R., Edmundson J.T. (1984), Orthodontic tooth movement analysed by the finite element method. Biomaterials, 5, 347-351.
    • (1984) Biomaterials , vol.5 , pp. 347-351
    • Williams, K.R.1    Edmundson, J.T.2