메뉴 건너뛰기




Volumn 14, Issue 10, 2003, Pages 1829-1838

Analysis of signal attenuation for quantification of a planar imaging technique

Author keywords

Attenuation; Planar imaging technique; Secondary emission; Spray

Indexed keywords

ATTENUATION; FLUORESCENCE; IMAGE ANALYSIS; LIGHT SCATTERING;

EID: 0242274412     PISSN: 09570233     EISSN: None     Source Type: Journal    
DOI: 10.1088/0957-0233/14/10/313     Document Type: Article
Times cited : (18)

References (19)
  • 1
  • 5
    • 0010043719 scopus 로고    scopus 로고
    • Attenuation effects on imaging diagnostics of hollow-cone sprays
    • Sick V and Stojkovic B 2001 Attenuation effects on imaging diagnostics of hollow-cone sprays Appl. Opt. 40 2435-42
    • (2001) Appl. Opt. , vol.40 , pp. 2435-2442
    • Sick, V.1    Stojkovic, B.2
  • 6
    • 30544441768 scopus 로고    scopus 로고
    • Accounting for laser extinction, signal attenuation, and secondary emission while performing optical patternation in a single plane
    • Madison, WI: ILASS-Americas 2002
    • Brown C T, McDonell V G and Talley D G 2002 Accounting for laser extinction, signal attenuation, and secondary emission while performing optical patternation in a single plane ILASS Americas 15th Ann. Conf. on Liquid Atomization and Spray Systems (Madison, WI: ILASS-Americas 2002)
    • (2002) ILASS Americas 15th Ann. Conf. on Liquid Atomization and Spray Systems
    • Brown, C.T.1    McDonell, V.G.2    Talley, D.G.3
  • 10
    • 0037055175 scopus 로고    scopus 로고
    • Simulating the effects of multiple scattering on images of dense sprays and particle fields
    • Jermy M C and Allen A 2002 Simulating the effects of multiple scattering on images of dense sprays and particle fields Appl. Opt. 41 4188-96
    • (2002) Appl. Opt. , vol.41 , pp. 4188-4196
    • Jermy, M.C.1    Allen, A.2
  • 12
    • 0035330924 scopus 로고    scopus 로고
    • A study of parameters that influence the accuracy of the planar droplet sizing (PDS) technique
    • Domann R and Hardalupas Y 2001 A study of parameters that influence the accuracy of the planar droplet sizing (PDS) technique Part. Part. Syst. Charact. 18 3-11
    • (2001) Part. Part. Syst. Charact. , vol.18 , pp. 3-11
    • Domann, R.1    Hardalupas, Y.2
  • 13
    • 0242315409 scopus 로고    scopus 로고
    • Semi-quantitative measurement of spray distribution using planar imaging technique
    • Lee K, Jung K, Yoon Y and Jeung I-S 1999 Semi-quantitative measurement of spray distribution using planar imaging technique 2nd ASPACC B2-055
    • (1999) 2nd ASPACC B2-055
    • Lee, K.1    Jung, K.2    Yoon, Y.3    Jeung, I.-S.4
  • 14
    • 84983143179 scopus 로고    scopus 로고
    • Fuel injector characterization using laser diagnostics at atmospheric and elevated pressures
    • Zelina J, Rodrigue A and Sankar S 1998 Fuel injector characterization using laser diagnostics at atmospheric and elevated pressures AIAA 98-0148
    • (1998) AIAA 98-0148
    • Zelina, J.1    Rodrigue, A.2    Sankar, S.3
  • 17
    • 0041925289 scopus 로고    scopus 로고
    • Quantitative measurement of fuel mass distribution using planar imaging technique
    • submitted
    • Koh H, Jung K, Yoon Y, Lee K and Jeong K-S 2003 Quantitative measurement of fuel mass distribution using planar imaging technique Opt. Laser Technol. submitted
    • (2003) Opt. Laser Technol.
    • Koh, H.1    Jung, K.2    Yoon, Y.3    Lee, K.4    Jeong, K.-S.5
  • 19
    • 0000466561 scopus 로고    scopus 로고
    • Investigation of spatially resolved light absorption in a spark-ignition engine fueled with propane air
    • Hildenbrand F, Schulz C, Wagner E and Sick V 1999 Investigation of spatially resolved light absorption in a spark-ignition engine fueled with propane air Appl. Opt. 38 1452-8
    • (1999) Appl. Opt. , vol.38 , pp. 1452-1458
    • Hildenbrand, F.1    Schulz, C.2    Wagner, E.3    Sick, V.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.