메뉴 건너뛰기




Volumn 57, Issue 4, 2003, Pages 1150-1158

Comparison of an image registration technique based on normalized mutual information with a standard method utilizing implanted markers in the staged radiosurgical treatment of large arteriovenous malformations

Author keywords

Arteriovenous malformation; Gamma knife; Image registration; Radiosurgery

Indexed keywords

MAGNETIC RESONANCE IMAGING; ONCOLOGY; TUMORS;

EID: 0142248774     PISSN: 03603016     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0360-3016(03)01568-2     Document Type: Article
Times cited : (15)

References (13)
  • 1
    • 0025157045 scopus 로고
    • Comparison of different radiation types and irradiation geometries in stereotactic radiosurgery
    • Phillips M.H., Frankel K.A., Lyman J.T., et al. Comparison of different radiation types and irradiation geometries in stereotactic radiosurgery. Int J Radiat Oncol Biol Phys. 18:1990;211-220.
    • (1990) Int J Radiat Oncol Biol Phys , vol.18 , pp. 211-220
    • Phillips, M.H.1    Frankel, K.A.2    Lyman, J.T.3
  • 2
    • 0031755802 scopus 로고    scopus 로고
    • Staged volume radiosurgery followed by microsurgical resection: A novel treatment for giant cerebral arteriovenous malformations: Technical case report
    • Firlik A.D., Levy E.I., Kondziolka D., et al. Staged volume radiosurgery followed by microsurgical resection A novel treatment for giant cerebral arteriovenous malformations: Technical case report. Neurosurgery. 43:1998;1223-12228.
    • (1998) Neurosurgery , vol.43 , pp. 1223-12228
    • Firlik, A.D.1    Levy, E.I.2    Kondziolka, D.3
  • 3
    • 0034037102 scopus 로고    scopus 로고
    • Repeated radiosurgery for incompletely obliterated arteriovenous malformations
    • Maesawa S., Flickinger J.C., Kondziolka D., et al. Repeated radiosurgery for incompletely obliterated arteriovenous malformations. J Neurosurg. 92:2000;961-970.
    • (2000) J Neurosurg , vol.92 , pp. 961-970
    • Maesawa, S.1    Flickinger, J.C.2    Kondziolka, D.3
  • 4
    • 0034307074 scopus 로고    scopus 로고
    • The rationale and technique of staged-volume arteriovenous malformation radiosurgery
    • Pollock B.E., Kline R.W., Stafford S.L., et al. The rationale and technique of staged-volume arteriovenous malformation radiosurgery. Int J Radiat Oncol Biol Phys. 48:2000;817-824.
    • (2000) Int J Radiat Oncol Biol Phys , vol.48 , pp. 817-824
    • Pollock, B.E.1    Kline, R.W.2    Stafford, S.L.3
  • 5
    • 0025134050 scopus 로고
    • A non-invasive method for fractionated stereotactic irradiation of brain tumors with linear accelerator
    • Hariz M.I., Henriksson R., Lofroth P.O., et al. A non-invasive method for fractionated stereotactic irradiation of brain tumors with linear accelerator. Radiother Oncol. 17:1990;57-72.
    • (1990) Radiother Oncol , vol.17 , pp. 57-72
    • Hariz, M.I.1    Henriksson, R.2    Lofroth, P.O.3
  • 6
    • 0027981561 scopus 로고
    • Adaptation and verification of the relocatable Gill-Thomas-Cosman frame in stereotactic radiotherapy
    • Kooy H.M., Dunbar S.F., Tarbell N.J., et al. Adaptation and verification of the relocatable Gill-Thomas-Cosman frame in stereotactic radiotherapy. Int J Radiat Oncol Biol Phys. 30:1994;685-691.
    • (1994) Int J Radiat Oncol Biol Phys , vol.30 , pp. 685-691
    • Kooy, H.M.1    Dunbar, S.F.2    Tarbell, N.J.3
  • 7
    • 0142201304 scopus 로고
    • Re-establishment of stereotactic coordinates for fractionated radiosurgery treatments
    • [Abstract]
    • Smith V., Petti P., Verhey L. Re-establishment of stereotactic coordinates for fractionated radiosurgery treatments. [Abstract] Med Phys. 21:1994;919.
    • (1994) Med Phys , vol.21 , pp. 919
    • Smith, V.1    Petti, P.2    Verhey, L.3
  • 9
    • 0023395668 scopus 로고
    • Stereotaxic localization of intracranial targets
    • Siddon R.L., Barth N.H. Stereotaxic localization of intracranial targets. Int J Radiat Oncol Biol Phys. 13:1987;1241-1246.
    • (1987) Int J Radiat Oncol Biol Phys , vol.13 , pp. 1241-1246
    • Siddon, R.L.1    Barth, N.H.2
  • 10
    • 0024592222 scopus 로고
    • Accurate 3D registration of CT, PET and/or MR images of the brain
    • Pelizzari C.A., Chen G.T.Y., Spelbring D.R., et al. Accurate 3D registration of CT, PET and/or MR images of the brain. J Comput Assist Tomogr. 13:1989;20-26.
    • (1989) J Comput Assist Tomogr , vol.13 , pp. 20-26
    • Pelizzari, C.A.1    Chen, G.T.Y.2    Spelbring, D.R.3
  • 11
    • 18844474299 scopus 로고    scopus 로고
    • Comparison and evaluation of retrospective intermodality brain image registration techniques
    • West J., Fitzpatrick J.M., Wang M.Y., et al. Comparison and evaluation of retrospective intermodality brain image registration techniques. J Comput Assist Tomogr. 21:1997;554-566.
    • (1997) J Comput Assist Tomogr , vol.21 , pp. 554-566
    • West, J.1    Fitzpatrick, J.M.2    Wang, M.Y.3
  • 12
    • 0032762144 scopus 로고    scopus 로고
    • An overlap invariant entropy measure of 3D medical image alignment
    • Studholme C., Hill D.L.G., Hawkes D.J. An overlap invariant entropy measure of 3D medical image alignment. Pattern Recog. 32:1999;71-86.
    • (1999) Pattern Recog , vol.32 , pp. 71-86
    • Studholme, C.1    Hill, D.L.G.2    Hawkes, D.J.3
  • 13
    • 0034433348 scopus 로고    scopus 로고
    • Image registration and calculation of a biologically effective dose for multisession radiosurgical treatments
    • Knisely J.P., Bond J.E., Yue N.J., et al. Image registration and calculation of a biologically effective dose for multisession radiosurgical treatments. J Neurosurg. 93:(Suppl. 3):2000;208-218.
    • (2000) J Neurosurg , vol.93 , Issue.SUPPL. 3 , pp. 208-218
    • Knisely, J.P.1    Bond, J.E.2    Yue, N.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.