메뉴 건너뛰기




Volumn 125, Issue 5, 2003, Pages 639-647

Comparison of Thermal Insulation Performance of Fibrous Materials for the Advanced Space Suit

Author keywords

[No Author keywords available]

Indexed keywords

HEAT FLUX; MULTILAYERS; THERMAL CONDUCTIVITY; THERMAL INSULATION; VECTORS;

EID: 0142245472     PISSN: 01480731     EISSN: None     Source Type: Journal    
DOI: 10.1115/1.1611885     Document Type: Article
Times cited : (54)

References (23)
  • 1
    • 0010678223 scopus 로고
    • Mars Exploration Strategies: A Reference Program and Comparison of Alternative Architectures
    • AIAA Transactions 93-4212
    • Weaver, D. B., and Duke, M. B., 1993, "Mars Exploration Strategies: A Reference Program and Comparison of Alternative Architectures," AIAA Transactions, 93-4212, pp. 5-6.
    • (1993) AIAA Transactions , pp. 5-6
    • Weaver, D.B.1    Duke, M.B.2
  • 5
    • 0142254928 scopus 로고    scopus 로고
    • Advanced Suit Insulation Materials Status at Crew and Thermal Systems Division
    • Johnson Space Center, Houston, TX
    • Trevino, L. A., and Omdoff, E. S., 1999, "Advanced Suit Insulation Materials Status at Crew and Thermal Systems Division," Internal NASA/JSC Review, Johnson Space Center, Houston, TX, pp. 11-12.
    • (1999) Internal NASA/JSC Review , pp. 11-12
    • Trevino, L.A.1    Omdoff, E.S.2
  • 6
    • 0142223837 scopus 로고    scopus 로고
    • Thermal Conductivity Testing of Several Candidate Insulation Materials for Advanced Space Suit
    • Johnson Space Center, Houston, TX
    • Cross, C., 1998, "Thermal Conductivity Testing of Several Candidate Insulation Materials for Advanced Space Suit," Advanced Materials Laboratory Quick Look Test Report, AML-98-07, Johnson Space Center, Houston, TX.
    • (1998) Advanced Materials Laboratory Quick Look Test Report, AML-98-07
    • Cross, C.1
  • 7
    • 0142161854 scopus 로고    scopus 로고
    • Thermal Insulation Performance of Textile Structures for Spacesuit Application at Martian Pressure and Temperature
    • Industrial Fabrics Association, Arlington, VA
    • Omdoff, E., and Trevino, L., 2000, "Thermal Insulation Performance of Textile Structures for Spacesuit Application at Martian Pressure and Temperature," Proc. 2nd International Conference on Safety and Protective Fabrics, Industrial Fabrics Association, Arlington, VA.
    • (2000) Proc. 2nd International Conference on Safety and Protective Fabrics
    • Omdoff, E.1    Trevino, L.2
  • 8
    • 0000930125 scopus 로고
    • Heat Transfer by Gas Conduction and Radiation in Fibrous Insulations
    • Verschoor, J. D., Greebler, P., and Manville, N. J., 1952, "Heat Transfer by Gas Conduction and Radiation in Fibrous Insulations," ASME Transactions, 74(6), pp. 961-967.
    • (1952) ASME Transactions , vol.74 , Issue.6 , pp. 961-967
    • Verschoor, J.D.1    Greebler, P.2    Manville, N.J.3
  • 11
    • 0142192717 scopus 로고    scopus 로고
    • 1970, "Temperature Adaptable Fabrics," U.S. Patent No. 1,270,216
    • J. P. Stevens and Company, Inc., 1970, "Temperature Adaptable Fabrics," U.S. Patent No. 1,270,216.
    • Stevens, J.P.1
  • 12
    • 0142192715 scopus 로고    scopus 로고
    • Super Insulator
    • Fisher, A., 1998, "Super Insulator," Popular Science, 253(6), p. 43.
    • (1998) Popular Science , vol.253 , Issue.6 , pp. 43
    • Fisher, A.1
  • 14
    • 0142192714 scopus 로고
    • Reversible Chemisorption Gas-Gap Thermal Switch
    • Item 59
    • Jones, J., Bard, S., and Blue, G., 1991, "Reversible Chemisorption Gas-Gap Thermal Switch," NASA Tech Brief, 15(11), Item 59.
    • (1991) NASA Tech Brief , vol.15 , Issue.11
    • Jones, J.1    Bard, S.2    Blue, G.3
  • 15
    • 0000890380 scopus 로고    scopus 로고
    • Feasibility Demonstration of a Thermal Switch for Dual Temperature IR Focal Plane Cooling
    • Ross, R. G. ed., Plenum Press, New York
    • Johnson, D. L., and Wu, J. J., 1997, "Feasibility Demonstration of a Thermal Switch for Dual Temperature IR Focal Plane Cooling," Cryocoolers 9, Ross, R. G. ed., Plenum Press, New York, pp. 795-805.
    • (1997) Cryocoolers 9 , pp. 795-805
    • Johnson, D.L.1    Wu, J.J.2
  • 18
    • 0025795235 scopus 로고
    • Aerogel-A High Performance Insulating Material at 0.1 Bar
    • Graves, R. S. and Wysocki, D. C., eds., American Society for Testing and Materials, Philadelphia, PA
    • Hunt, A. J., Jantzen, C. A., and Cao, W., 1991, "Aerogel-A High Performance Insulating Material at 0.1 Bar," Insulation Materials: Testing and Applications, II, Graves, R. S. and Wysocki, D. C., eds., American Society for Testing and Materials, Philadelphia, PA, pp. 455-463.
    • (1991) Insulation Materials: Testing and Applications, II , pp. 455-463
    • Hunt, A.J.1    Jantzen, C.A.2    Cao, W.3
  • 19
    • 0142161855 scopus 로고    scopus 로고
    • Fiber Innovation Technology Inc., 2000, "4DG Deep-Grooved Fiber" [Online], p. 6. Available: http://www.fitfibers.com/publications.htm
    • (2000) "4DG Deep-Grooved Fiber" [Online] , pp. 6
  • 22
    • 0142223835 scopus 로고    scopus 로고
    • personal communication, Dupont Performance Insulations, Kinston, NC
    • Benim, T., 2001, personal communication, Dupont Performance Insulations, Kinston, NC.
    • (2001)
    • Benim, T.1
  • 23
    • 0142192716 scopus 로고    scopus 로고
    • Personal communication, Clemson University, Clemson, NC
    • Vaughn, E., 2001, Personal communication, Clemson University, Clemson, NC.
    • (2001)
    • Vaughn, E.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.