-
1
-
-
85024957600
-
CT gel dosimetry technique: Comparison of a planned and measured 3D stereotactic dose volume
-
Audet C, Hilts M, Jirasek A and Duzenli C 2002 CT gel dosimetry technique: comparison of a planned and measured 3D stereotactic dose volume J. Appl. Clin. Med. Phys. 3 110-8
-
(2002)
J. Appl. Clin. Med. Phys.
, vol.3
, pp. 110-118
-
-
Audet, C.1
Hilts, M.2
Jirasek, A.3
Duzenli, C.4
-
2
-
-
0031950630
-
Experimental procedure for the manufacture and calibration of polyacrylamide gel (PAG) for magnetic resonance imaging (MRI radiation dosimetry)
-
Baldock C, Burford R P, Billingham N, Wagner G S, Patval S, Badawi R D and Keevil S F 1998 Experimental procedure for the manufacture and calibration of polyacrylamide gel (PAG) for magnetic resonance imaging (MRI radiation dosimetry) Phys. Med. Biol. 43 695-702
-
(1998)
Phys. Med. Biol.
, vol.43
, pp. 695-702
-
-
Baldock, C.1
Burford, R.P.2
Billingham, N.3
Wagner, G.S.4
Patval, S.5
Badawi, R.D.6
Keevil, S.F.7
-
4
-
-
0000226489
-
A dosimetry phantom for external beam radiation therapy of the breast using radiation-sensitive polymer gels and MRI
-
Baldock C, Hassler C, Keevil S F, Greener A G, Billingham N and Burford R P 1996 A dosimetry phantom for external beam radiation therapy of the breast using radiation-sensitive polymer gels and MRI Med. Phys. 23 1490
-
(1996)
Med. Phys.
, vol.23
, pp. 1490
-
-
Baldock, C.1
Hassler, C.2
Keevil, S.F.3
Greener, A.G.4
Billingham, N.5
Burford, R.P.6
-
7
-
-
0035739868
-
Polymer gels for magnetic resonance imaging of radiation dose distributions at normal room atmosphere
-
Fong P, Keil D C, Does M D and Gore J C 2001 Polymer gels for magnetic resonance imaging of radiation dose distributions at normal room atmosphere Phys. Med. Biol. 46 3105-13
-
(2001)
Phys. Med. Biol.
, vol.46
, pp. 3105-3113
-
-
Fong, P.1
Keil, D.C.2
Does, M.D.3
Gore, J.C.4
-
8
-
-
0029838960
-
Radiation dose distributions in three dimensions from tomographic optical density scanning of polymer gels: I. Development of an optical scanner
-
Gore J C, Ranade M, Maryanski M J and Schulz R J 1996 Radiation dose distributions in three dimensions from tomographic optical density scanning of polymer gels: I. Development of an optical scanner Phys. Med. Biol. 41 2695-704
-
(1996)
Phys. Med. Biol.
, vol.41
, pp. 2695-2704
-
-
Gore, J.C.1
Ranade, M.2
Maryanski, M.J.3
Schulz, R.J.4
-
9
-
-
0033804968
-
Polymer gel dosimetry using x-ray computer tomography: A feasibility study
-
Hilts M, Audet C, Duzenli C and Jirasek A 2000 Polymer gel dosimetry using x-ray computer tomography: a feasibility study Phys. Med. Biol. 45 2559-71
-
(2000)
Phys. Med. Biol.
, vol.45
, pp. 2559-2571
-
-
Hilts, M.1
Audet, C.2
Duzenli, C.3
Jirasek, A.4
-
10
-
-
0041409609
-
3-D radiation dosimetry by MRI: Solvent proton relaxation enhancement by radiation-controlled polymerisation and cross-linking in gels
-
Maryanski M J, Gore J C and Schulz R J 1992 3-D radiation dosimetry by MRI: solvent proton relaxation enhancement by radiation-controlled polymerisation and cross-linking in gels Proc. Society of Magnetic Resonance in Medicine
-
(1992)
Proc. Society of Magnetic Resonance in Medicine
-
-
Maryanski, M.J.1
Gore, J.C.2
Schulz, R.J.3
-
11
-
-
0027258459
-
NMR relaxation enhancement in gels polymerized and cross-linked by ionzing radiation: A new approach to 3D dosimetry by MRI
-
Maryanski M J, Gore J C, Kennan R P and Schulz R J 1993 NMR relaxation enhancement in gels polymerized and cross-linked by ionzing radiation: a new approach to 3D dosimetry by MRI Magn. Reson. Imag. 11 253-8
-
(1993)
Magn. Reson. Imag.
, vol.11
, pp. 253-258
-
-
Maryanski, M.J.1
Gore, J.C.2
Kennan, R.P.3
Schulz, R.J.4
-
12
-
-
0029801087
-
Radiation dose distributions in three dimensions from tomographic optical density scanning of polymer gels: II. Optical properties of the BANG polymer gel
-
Maryanski M J, Zastavker Y Z and Gore J C 1996 Radiation dose distributions in three dimensions from tomographic optical density scanning of polymer gels: II. Optical properties of the BANG polymer gel Phys. Med. Biol. 41 2705-17
-
(1996)
Phys. Med. Biol.
, vol.41
, pp. 2705-2717
-
-
Maryanski, M.J.1
Zastavker, Y.Z.2
Gore, J.C.3
-
13
-
-
0042389494
-
Ultrasound tomography imaging of radiation dose distributions in polymer gel dosimeters
-
Mather M L and Baldock C 2003 Ultrasound tomography imaging of radiation dose distributions in polymer gel dosimeters Med. Phys. 30 2140-8
-
(2003)
Med. Phys.
, vol.30
, pp. 2140-2148
-
-
Mather, M.L.1
Baldock, C.2
-
16
-
-
0037153912
-
Investigation of ultrasonic properties of PAG and MAGIC polymer gel dosimeters
-
Mather M L, DeDeene Y, Whittaker A K, Simon G, R R and Baldock C 2002b Investigation of ultrasonic properties of PAG and MAGIC polymer gel dosimeters Phys. Med. Biol. 47 4397-408
-
(2002)
Phys. Med. Biol.
, vol.47
, pp. 4397-4408
-
-
Mather, M.L.1
DeDeene, Y.2
Whittaker, A.K.3
Simon, G.R.R.4
Baldock, C.5
-
20
-
-
0034758028
-
Investigation of the x-ray computed tomography absorbed dose response characteristics of various polymer gel dosimeter compositions
-
Trapp J V, Back S A J, LePage M, Michael G and Baldock C 2001 Investigation of the x-ray computed tomography absorbed dose response characteristics of various polymer gel dosimeter compositions Phys. Med. Biol. 46 2939-51
-
(2001)
Phys. Med. Biol.
, vol.46
, pp. 2939-2951
-
-
Trapp, J.V.1
Back, S.A.J.2
LePage, M.3
Michael, G.4
Baldock, C.5
-
21
-
-
0037038919
-
Attenuation of diagnostic energy photons by polymer gel dosimeters
-
Trapp J V, Michael G, DeDeene Y and Baldock C 2002 Attenuation of diagnostic energy photons by polymer gel dosimeters Phys. Med. Biol. 47 4247-58
-
(2002)
Phys. Med. Biol.
, vol.47
, pp. 4247-4258
-
-
Trapp, J.V.1
Michael, G.2
DeDeene, Y.3
Baldock, C.4
|