메뉴 건너뛰기




Volumn 2, Issue , 2002, Pages 1193-1196

The Potential of In-Beam Positron-Emission-Tomography for Proton Therapy Monitoring: First Phantom Experiments

Author keywords

In beam PET; Proton therapy monitoring

Indexed keywords

CARBON; IONS; POSITRON EMISSION TOMOGRAPHY; PROTONS; TUMORS;

EID: 0142210158     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (4)

References (12)
  • 3
    • 0033606589 scopus 로고    scopus 로고
    • Positron emission tomography for quality assurance of cancer therapy with light ion beams
    • W. Enghardt, J. Debus, T. Haberer, B. G. Hasch, R. Hinz, O. Jäkel et al., "Positron emission tomography for quality assurance of cancer therapy with light ion beams," Nucl. Phys. A, vol. 654, pp. 1047c-1050c, 1999.
    • (1999) Nucl. Phys. A , vol.654
    • Enghardt, W.1    Debus, J.2    Haberer, T.3    Hasch, B.G.4    Hinz, R.5    Jäkel, O.6
  • 6
    • 0033769670 scopus 로고    scopus 로고
    • Potential application of PET in quality assurance of proton therapy
    • K. Parodi and W. Enghardt, "Potential application of PET in quality assurance of proton therapy," Phys. Med. Biol., vol. 45, pp. N151-N156, 2000.
    • (2000) Phys. Med. Biol. , vol.45
    • Parodi, K.1    Enghardt, W.2
  • 8
    • 0027649740 scopus 로고
    • Proton therapy in combination with PET as monitor: A feasibility study
    • A. M. Paans and J. M. Schippers, "Proton therapy in combination with PET as monitor: a feasibility study," IEEE Trans. Nucl. Sci., vol. 40, pp. 1041-1044, 1993.
    • (1993) IEEE Trans. Nucl. Sci. , vol.40 , pp. 1041-1044
    • Paans, A.M.1    Schippers, J.M.2
  • 9
    • 0027572364 scopus 로고
    • Is it possible to verify directly a proton-treatment plan using positron emission tomography?
    • S. Vynckier, S. Derreumaux, F. Richard, A. Bol, C. Michel and A. Wambersie, "Is it possible to verify directly a proton-treatment plan using positron emission tomography?," Radiother. Oncol., vol. 26, pp. 275-277, 1993.
    • (1993) Radiother. Oncol. , vol.26 , pp. 275-277
    • Vynckier, S.1    Derreumaux, S.2    Richard, F.3    Bol, A.4    Michel, C.5    Wambersie, A.6
  • 10
    • 0030025292 scopus 로고    scopus 로고
    • Proton dose monitoring with PET: Quantitative studies in Lucite
    • U. Oelfke, G. K. Y. Lam and M. S. Atkins, "Proton dose monitoring with PET: quantitative studies in Lucite," Phys. Med. Biol., vol. 41, pp. 177-196, 1996.
    • (1996) Phys. Med. Biol. , vol.41 , pp. 177-196
    • Oelfke, U.1    Lam, G.K.Y.2    Atkins, M.S.3
  • 12
    • 0142174193 scopus 로고    scopus 로고
    • Nuclear Reaction Data Center network which is coordinated by the IAEA Nuclear Data Section
    • Nuclear Reaction Data Center network which is coordinated by the IAEA Nuclear Data Section, 2000. Available: http://www.nndc.bnl.gov/nndc/exfor.
    • (2000)


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.