Volumn 4, Issue 2, 2003, Pages 108-115

A morphological-mechanical explanation of edge restenosis in lesions treated with vascular brachytherapy

Author keywords

Edge effect; Edge restenosis; Geographic miss; Vascular brachytherapy

Indexed keywords

ARTERY CATHETER; ARTICLE; BLOOD VESSEL INJURY; BLOOD VESSEL WALL; BRACHYTHERAPY; CORONARY STENT; EDGE RESTENOSIS; FUNCTIONAL MORPHOLOGY; MECHANICAL STRESS; PREDICTION; PRIORITY JOURNAL; RESTENOSIS; STENT; STRESS; VASCULAR LESION; VASODILATATION;

EID: 0142186129     PISSN: 15221865     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1522-1865(03)00147-1     Document Type: Article
Times cited : (9)

References (25)
  • 1
    • 0034602820 scopus 로고    scopus 로고
    • Short- and intermediate-term results of (32)P radioactive beta-emitting stent implantation in patients with coronary artery disease: The Milan dose-response study
    • Albiero R., Adamian M., Kobayashi N., Amato A., Vaghetti M., Di Mario C., Colombo A. Short- and intermediate-term results of (32)P radioactive beta-emitting stent implantation in patients with coronary artery disease: the Milan dose-response study. Circulation. 101(1):2000;18-26.
    • (2000) Circulation , vol.101 , Issue.1 , pp. 18-26
    • Albiero, R.1    Adamian, M.2    Kobayashi, N.3    Amato, A.4    Vaghetti, M.5    Di Mario, C.6    Colombo, A.7
  • 3
    • 0035869310 scopus 로고    scopus 로고
    • Edge stenosis and geographical miss following intracoronary gamma radiation therapy for in-stent restenosis
    • Kim H.S., Waksman R., Cottin Y., Kollum M., Bhargava B., Mehran R., Chan R.C., Mintz G.S. Edge stenosis and geographical miss following intracoronary gamma radiation therapy for in-stent restenosis. J Am Coll Cardiol. 37(4):2001;1026-1030.
    • (2001) J Am Coll Cardiol , vol.37 , Issue.4 , pp. 1026-1030
    • Kim, H.S.1    Waksman, R.2    Cottin, Y.3    Kollum, M.4    Bhargava, B.5    Mehran, R.6    Chan, R.C.7    Mintz, G.S.8
  • 4
    • 0035856530 scopus 로고    scopus 로고
    • Intracoronary beta-radiation exacerbates long-term neointima formation in balloon-injured pig coronary arteries
    • Coussement P.K., de Leon H., Ueno T., Salame M.Y., King S.B., Chronos N.A., Robinson K.A. Intracoronary beta-radiation exacerbates long-term neointima formation in balloon-injured pig coronary arteries. Circulation. 104(20):2001;2459-2464.
    • (2001) Circulation , vol.104 , Issue.20 , pp. 2459-2464
    • Coussement, P.K.1    De Leon, H.2    Ueno, T.3    Salame, M.Y.4    King, S.B.5    Chronos, N.A.6    Robinson, K.A.7
  • 5
    • 0034883748 scopus 로고    scopus 로고
    • Geographical miss during catheter-based intracoronary beta-radiation: Incidence and implications in the BRIE study. Beta-Radiation in Europe
    • Sianos G., Kay I.P., Costa M.A., Regar E., Kozuma K., de Feyter P.J., Boersma E., Disco C., Serruys P.W. Geographical miss during catheter-based intracoronary beta-radiation: incidence and implications in the BRIE study. Beta-Radiation in Europe. J Am Coll Cardiol. 38(2):2001;415-420.
    • (2001) J Am Coll Cardiol , vol.38 , Issue.2 , pp. 415-420
    • Sianos, G.1    Kay, I.P.2    Costa, M.A.3    Regar, E.4    Kozuma, K.5    De Feyter, P.J.6    Boersma, E.7    Disco, C.8    Serruys, P.W.9
  • 7
    • 0037422709 scopus 로고    scopus 로고
    • Estimation of the supplementary axial wall stress generated at peak flow by an arterial stenosis
    • Doriot P.A. Estimation of the supplementary axial wall stress generated at peak flow by an arterial stenosis. Phys Med Biol. 48(1):2003;127-138.
    • (2003) Phys Med Biol , vol.48 , Issue.1 , pp. 127-138
    • Doriot, P.A.1
  • 8
    • 0037636702 scopus 로고    scopus 로고
    • Effects of radial stretch on target lesion revascularization after percutaneous coronary intervention: An intravascular ultrasound study
    • Syeda B., Wexberg P., Gyongyosi M., Denk S., Beran G., Kiss K., Sperker W., Glogar D. Effects of radial stretch on target lesion revascularization after percutaneous coronary intervention: an intravascular ultrasound study. Can J Cardiol. 19(6):2003;691-697.
    • (2003) Can J Cardiol , vol.19 , Issue.6 , pp. 691-697
    • Syeda, B.1    Wexberg, P.2    Gyongyosi, M.3    Denk, S.4    Beran, G.5    Kiss, K.6    Sperker, W.7    Glogar, D.8
  • 9
    • 0030785467 scopus 로고    scopus 로고
    • Overestimation of acute lumen gain and late lumen loss by quantitative coronary angiography (compared with intravascular ultrasound) in stented lesions
    • Hoffmann R., Mintz G.S., Popma J.J., Satler L.F., Kent K.M., Pichard A.D., Leon M.B. Overestimation of acute lumen gain and late lumen loss by quantitative coronary angiography (compared with intravascular ultrasound) in stented lesions. Am J Cardiol. 80(10):1997;1277-1281.
    • (1997) Am J Cardiol , vol.80 , Issue.10 , pp. 1277-1281
    • Hoffmann, R.1    Mintz, G.S.2    Popma, J.J.3    Satler, L.F.4    Kent, K.M.5    Pichard, A.D.6    Leon, M.B.7
  • 15
    • 0037116577 scopus 로고    scopus 로고
    • Quantitative angiographic methods for appropriate end-point analysis, edge-effect evaluation, and prediction of recurrent restenosis after coronary brachytherapy with gamma irradiation
    • Lansky A.J., Dangas G., Mehran R., Desai K.J., Mintz G.S., Wu H., Pahy M., Stone G.W., Waksman R., Leon M.B. Quantitative angiographic methods for appropriate end-point analysis, edge-effect evaluation, and prediction of recurrent restenosis after coronary brachytherapy with gamma irradiation. J Am Coll Cardiol. 39(2):2002;274-280.
    • (2002) J Am Coll Cardiol , vol.39 , Issue.2 , pp. 274-280
    • Lansky, A.J.1    Dangas, G.2    Mehran, R.3    Desai, K.J.4    Mintz, G.S.5    Wu, H.6    Pahy, M.7    Stone, G.W.8    Waksman, R.9    Leon, M.B.10
  • 16
    • 0034673941 scopus 로고    scopus 로고
    • Safety of intracoronary gamma-radiation on uninjured reference segments during the first 6 months after treatment of in-stent restenosis: A serial intravascular ultrasound study
    • Ahmed J.M., Mintz G.S., Waksman R., Weissman N.J., Mehran R., Pichard A.D., Satler L.F., Kent K.M., Leon M.B. Safety of intracoronary gamma-radiation on uninjured reference segments during the first 6 months after treatment of in-stent restenosis: a serial intravascular ultrasound study. Circulation. 101(19):2000;2227-2230.
    • (2000) Circulation , vol.101 , Issue.19 , pp. 2227-2230
    • Ahmed, J.M.1    Mintz, G.S.2    Waksman, R.3    Weissman, N.J.4    Mehran, R.5    Pichard, A.D.6    Satler, L.F.7    Kent, K.M.8    Leon, M.B.9
  • 17
    • 0035873449 scopus 로고    scopus 로고
    • Serial intravascular ultrasound analysis of edge recurrence after intracoronary gamma radiation treatment of native artery in-stent restenosis lesions
    • May 15
    • Ahmed J.M., Mintz G.S., Waksman R., Lansky A.J., Mehran R., Wu H., Weissman N.J., Pichard A.D., Satler L.F., Kent K.M., Leon M.B. Serial intravascular ultrasound analysis of edge recurrence after intracoronary gamma radiation treatment of native artery in-stent restenosis lesions. Am J Cardiol. 87(10):2001;1145-1149. May 15.
    • (2001) Am J Cardiol , vol.87 , Issue.10 , pp. 1145-1149
    • Ahmed, J.M.1    Mintz, G.S.2    Waksman, R.3    Lansky, A.J.4    Mehran, R.5    Wu, H.6    Weissman, N.J.7    Pichard, A.D.8    Satler, L.F.9    Kent, K.M.10    Leon, M.B.11
  • 19
    • 0030898891 scopus 로고    scopus 로고
    • Serial intravascular ultrasound predictors of restenosis at the margins of Palmaz-Schatz stents
    • Hoffmann R., Mintz G.S., Kent K.M., Satler L.F., Pichard A.D., Popma J.J., Leon M.B. Serial intravascular ultrasound predictors of restenosis at the margins of Palmaz-Schatz stents. Am J Cardiol. 79(7):1997;951-953.
    • (1997) Am J Cardiol , vol.79 , Issue.7 , pp. 951-953
    • Hoffmann, R.1    Mintz, G.S.2    Kent, K.M.3    Satler, L.F.4    Pichard, A.D.5    Popma, J.J.6    Leon, M.B.7
  • 21
    • 0031454591 scopus 로고    scopus 로고
    • Structural analysis of 16 different coronary stent systems
    • Grewe P.H., Machraoui A., Deneke T., Barmeyer J., Muller K.M. Structural analysis of 16 different coronary stent systems. Z Kardiol. 86(12):1997;990-999.
    • (1997) Z Kardiol , vol.86 , Issue.12 , pp. 990-999
    • Grewe, P.H.1    Machraoui, A.2    Deneke, T.3    Barmeyer, J.4    Muller, K.M.5
  • 22
    • 0033396358 scopus 로고    scopus 로고
    • Measuring arterial strain induced by endovascular stents
    • Squire J.C., Rogers C., Edelman E.R. Measuring arterial strain induced by endovascular stents. Med Biol Eng Comput. 37(6):1999;692-698.
    • (1999) Med Biol Eng Comput , vol.37 , Issue.6 , pp. 692-698
    • Squire, J.C.1    Rogers, C.2    Edelman, E.R.3
  • 25
    • 0032698280 scopus 로고    scopus 로고
    • External beam radiation after stent implantation increases neointimal hyperplasia by augmenting smooth muscle cell proliferation and extracellular matrix accumulation
    • Hehrlein C., Kaiser S., Riessen R., Metz J., Fritz P., Kubler W. External beam radiation after stent implantation increases neointimal hyperplasia by augmenting smooth muscle cell proliferation and extracellular matrix accumulation. J Am Coll Cardiol. 34(2):1999;561-566.
    • (1999) J Am Coll Cardiol , vol.34 , Issue.2 , pp. 561-566
    • Hehrlein, C.1    Kaiser, S.2    Riessen, R.3    Metz, J.4    Fritz, P.5    Kubler, W.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.