메뉴 건너뛰기




Volumn 3, Issue , 2002, Pages 1402-1405

Impact of Acquisition Geometry and Patient Habitus on Lesion Detectability in Whole-Body FDG-PET: A Channelized Hotelling Observer Study

Author keywords

[No Author keywords available]

Indexed keywords

COMPUTER SIMULATION; DATA ACQUISITION; MEDICAL IMAGING; MONTE CARLO METHODS; PATIENT TREATMENT;

EID: 0142179055     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (14)

References (9)
  • 1
    • 0029849910 scopus 로고    scopus 로고
    • Optimization of noise-equivalent count rates in 3D PET
    • R. D. Badawi, P. K. Marsden, B. F. Cronin, J. L. Sutcliffe, et al., "Optimization of noise-equivalent count rates in 3D PET," Phys Med Biol, vol. 41, pp. 1755-1776, 1996.
    • (1996) Phys Med Biol , vol.41 , pp. 1755-1776
    • Badawi, R.D.1    Marsden, P.K.2    Cronin, B.F.3    Sutcliffe, J.L.4
  • 2
    • 0033024060 scopus 로고    scopus 로고
    • Capabilities of two- and three-dimensional FDG-PET for detecting small lesions and lymph nodes in the upper torso: A dynamic phantom study
    • R. R. Raylman, P. V. Kison, and R. L. Wahl, "Capabilities of two- and three-dimensional FDG-PET for detecting small lesions and lymph nodes in the upper torso: a dynamic phantom study," Eur J Nucl Med, vol. 26, pp. 39-45, 1999.
    • (1999) Eur J Nucl Med , vol.26 , pp. 39-45
    • Raylman, R.R.1    Kison, P.V.2    Wahl, R.L.3
  • 4
    • 0033376809 scopus 로고    scopus 로고
    • ROC and localization ROC analyses of lesion detection in whole-body FDG PET: Effects of acquisition mode, attenuation correction and reconstruction algorithm
    • T. H. Farquhar, J. Llacer, C. K. Hoh, J. Czernin, et al., "ROC and localization ROC analyses of lesion detection in whole-body FDG PET: effects of acquisition mode, attenuation correction and reconstruction algorithm," J Nucl Med, vol. 40, pp. 2043-2052, 1999.
    • (1999) J Nucl Med , vol.40 , pp. 2043-2052
    • Farquhar, T.H.1    Llacer, J.2    Hoh, C.K.3    Czernin, J.4
  • 6
    • 0020660172 scopus 로고
    • Correction for scattered radiation in a ring detector positron camera by integral transformation of the projections
    • M. Bergstrom, L. Eriksson, C. Bohm, G. Blomqvist, et al., "Correction for scattered radiation in a ring detector positron camera by integral transformation of the projections," J Comput Assist Tomog, vol. 7, pp. 42-50, 1983.
    • (1983) J Comput Assist Tomog , vol.7 , pp. 42-50
    • Bergstrom, M.1    Eriksson, L.2    Bohm, C.3    Blomqvist, G.4
  • 7
    • 0031076959 scopus 로고    scopus 로고
    • Evaluation of simulation-based scatter correction for 3-D PET cardiac imaging
    • C. C. Watson, D. Newport, M. E. Casey, R. A. deKemp, et al., "Evaluation of simulation-based scatter correction for 3-D PET cardiac imaging," IEEE Trans Nucl Sci, vol. 44, pp. 90-97, 1997.
    • (1997) IEEE Trans Nucl Sci , vol.44 , pp. 90-97
    • Watson, C.C.1    Newport, D.2    Casey, M.E.3    Dekemp, R.A.4
  • 8
    • 0031106959 scopus 로고    scopus 로고
    • Exact and approximate rebinning algorithms for 3-D PET data
    • M. Defrise, P. E. Kinahan, D. W. Townsend, C. Michel, et al., "Exact and approximate rebinning algorithms for 3-D PET data," IEEE Trans Nucl Sci, vol. 16, pp. 145-158, 1997.
    • (1997) IEEE Trans Nucl Sci , vol.16 , pp. 145-158
    • Defrise, M.1    Kinahan, P.E.2    Townsend, D.W.3    Michel, C.4
  • 9
    • 0035286822 scopus 로고    scopus 로고
    • Human- and model-observer performance in ramp-spectrum noise; effects of regularization and object variability
    • C. K. Abbey and H. H. Barrett, "Human- and model-observer performance in ramp-spectrum noise; effects of regularization and object variability," J Opt Soc Am A, vol. 18, pp. 473-488, 2001.
    • (2001) J Opt Soc Am A , vol.18 , pp. 473-488
    • Abbey, C.K.1    Barrett, H.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.