메뉴 건너뛰기




Volumn 20, Issue 7, 2003, Pages 617-619

Live Three-Dimensional Transthoracic Echocardiographic Identification of Discrete Subaortic Membranous Stenosis

Author keywords

Discrete subaortic membranous stenosis; Live three dimensional transthoracic echocardiography

Indexed keywords

ADULT; AORTA; AORTA STENOSIS; ARTICLE; BRAIN SCINTISCANNING; CASE REPORT; CLINICAL FEATURE; DISEASE SEVERITY; HEART MURMUR; HUMAN; IMAGE PROCESSING; INTERMETHOD COMPARISON; LIVE THREE DIMENSIONAL ECHOCARDIOGRAPHY; MALE; MEMBRANE; MITRAL VALVE; PHYSICAL EXAMINATION; PRIORITY JOURNAL; SUBSTANCE ABUSE; THREE DIMENSIONAL ECHOCARDIOGRAPHY; THREE DIMENSIONAL IMAGING;

EID: 0142169793     PISSN: 07422822     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1540-8175.2003.03055.x     Document Type: Article
Times cited : (21)

References (12)
  • 1
    • 0019524224 scopus 로고
    • Two-dimensional echocardiographic evaluation of discrete subaortic stenosis from the apical long axis view
    • DiSessa TG, Hagan AD, Isabel-Jones JB, et al: Two-dimensional echocardiographic evaluation of discrete subaortic stenosis from the apical long axis view. Am Heart J 1981;101:774-782.
    • (1981) Am Heart J , vol.101 , pp. 774-782
    • Disessa, T.G.1    Hagan, A.D.2    Isabel-Jones, J.B.3
  • 4
    • 0033040850 scopus 로고    scopus 로고
    • Use of three-dimensional echocardiography for analysis of outflow obstruction in congenital heart disease
    • Agata AD, Cromme-Dijkhuis AH, Meijboom FJ, et al: Use of three-dimensional echocardiography for analysis of outflow obstruction in congenital heart disease. Am J Cardiol 1999;83:921-925.
    • (1999) Am J Cardiol , vol.83 , pp. 921-925
    • Agata, A.D.1    Cromme-Dijkhuis, A.H.2    Meijboom, F.J.3
  • 5
    • 0031228717 scopus 로고    scopus 로고
    • Morphology and dynamic change of discrete subaortic stenosis can be imaged and quantified with three-dimensional transesophageal echocardiography
    • Ge S, Warner JG, Fowle EKM, et al: Morphology and dynamic change of discrete subaortic stenosis can be imaged and quantified with three-dimensional transesophageal echocardiography. J Am Soc Echocardiogr 1997;10:713-717.
    • (1997) J Am Soc Echocardiogr , vol.10 , pp. 713-717
    • Ge, S.1    Warner, J.G.2    Fowle, E.K.M.3
  • 10
    • 0020334431 scopus 로고
    • Discrete membranous subaortic stenosis in adult patient obtained by echocardiography and not proved by catheterization
    • Grenadier E, Keidar S, Alpan G, et al: Discrete membranous subaortic stenosis in adult patient obtained by echocardiography and not proved by catheterization. Angiology 1982;33:800-805.
    • (1982) Angiology , vol.33 , pp. 800-805
    • Grenadier, E.1    Keidar, S.2    Alpan, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.